MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2022-068, NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 22022-04-25025 April 2022 NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 2 L-2022-012, Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3)2022-03-16016 March 2022 Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2021-161, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2021-08-24024 August 2021 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2020-154, CFR 140.21 Licensee Guarantees of Payment of Deferred Preminms2020-11-12012 November 2020 CFR 140.21 Licensee Guarantees of Payment of Deferred Preminms L-2020-041, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2020-04-14014 April 2020 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2020-040, Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2020-03-11011 March 2020 Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2020-004, Mock Adversary Force2020-01-13013 January 2020 Mock Adversary Force L-2019-216, Proposed Turkey Point Units 6 and 7; Seabrook Station; Duane Arnold Energy Center; and Point Beach Units 1 and 2 - Re-issuance of Official Service List2019-12-19019 December 2019 Proposed Turkey Point Units 6 and 7; Seabrook Station; Duane Arnold Energy Center; and Point Beach Units 1 and 2 - Re-issuance of Official Service List L-2019-155, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events2019-11-21021 November 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events L-2019-202, CFR 50.46 - Emergency Core Cooling System LOCA 30-Day Report2019-11-19019 November 2019 CFR 50.46 - Emergency Core Cooling System LOCA 30-Day Report L-2019-182, Duane Arnold, and Point Beach Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2019-10-22022 October 2019 Duane Arnold, and Point Beach Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2019-161, License Amendment Request (TSCR-186): Removal of License Condition 2.C.(3), Fire Protection Program2019-09-25025 September 2019 License Amendment Request (TSCR-186): Removal of License Condition 2.C.(3), Fire Protection Program L-2019-157, Supplement to License Amendment Request (TSCR-183): Application to Revise Technical Specifications for the Permanently Defueled Condition2019-09-12012 September 2019 Supplement to License Amendment Request (TSCR-183): Application to Revise Technical Specifications for the Permanently Defueled Condition L-2019-133, Duane Arnold Energy Center and Point Beach, Units 1 & 2 -10 CFR Part 95 Facility Security Clearances2019-08-19019 August 2019 Duane Arnold Energy Center and Point Beach, Units 1 & 2 -10 CFR Part 95 Facility Security Clearances L-2019-141, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation. L-2019-142, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions. L-2019-146, Official Service List Update2019-07-22022 July 2019 Official Service List Update L-2019-134, Units 1 and 2 - Quality Assurance Topical Report, Revision 22, Annual Submittal2019-07-12012 July 2019 Units 1 and 2 - Quality Assurance Topical Report, Revision 22, Annual Submittal L-2019-105, License Amendment Request (TSCR-183): Application to Revise Operating License and Technical Specifications for Permanently Defueled Condition2019-06-20020 June 2019 License Amendment Request (TSCR-183): Application to Revise Operating License and Technical Specifications for Permanently Defueled Condition L-2019-093, Duane Arnold Energy Center and Point Beach, Units 1 & 2 - Official Service List Update2019-04-25025 April 2019 Duane Arnold Energy Center and Point Beach, Units 1 & 2 - Official Service List Update L-2019-050, License Amendment Request (TSCR-181): Application to Align Technical Specification Staffing and Administrative Requirements for Permanently Defueled Condition2019-04-19019 April 2019 License Amendment Request (TSCR-181): Application to Align Technical Specification Staffing and Administrative Requirements for Permanently Defueled Condition L-2019-070, License Amendment Request (TSCR-182): Proposed Changes to the Emergency Plan for Permanently Defueled Condition2019-04-0909 April 2019 License Amendment Request (TSCR-182): Proposed Changes to the Emergency Plan for Permanently Defueled Condition L-2019-045, NextEra Energy Duane Arnold, Ilc - Independent Spent Fuel Storage Installation (ISFSI) - Decommissioning Funding Status Reports, Financial Assurance Update2019-03-25025 March 2019 NextEra Energy Duane Arnold, Ilc - Independent Spent Fuel Storage Installation (ISFSI) - Decommissioning Funding Status Reports, Financial Assurance Update L-2019-057, Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2019-03-19019 March 2019 Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2019-052, Florida Power and Light Co. - Nuclear Property Insurance - 10 CFR 50.54(w)(3)2019-03-18018 March 2019 Florida Power and Light Co. - Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2019-047, Request for Exemption from 10 CFR 73.55(p)(1)(i) and (II) Related to the Suspension of Security Measures in an Emergency or During Severe Weather2019-02-28028 February 2019 Request for Exemption from 10 CFR 73.55(p)(1)(i) and (II) Related to the Suspension of Security Measures in an Emergency or During Severe Weather L-2019-009, Certification of Permanent Cessation of Power Operations2019-01-18018 January 2019 Certification of Permanent Cessation of Power Operations L-2018-214, Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2018-12-0303 December 2018 Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2018-068, Florida Power and Light Co. - Response to Request for Additional Information Re Decommissioning Funding Plan Updates for Independent Spent Fuel Storage Installations2018-04-0303 April 2018 Florida Power and Light Co. - Response to Request for Additional Information Re Decommissioning Funding Plan Updates for Independent Spent Fuel Storage Installations L-2018-060, Florida Power & Light: Nuclear Property Insurance - 10 CFR 50.54(w)(3)2018-03-26026 March 2018 Florida Power & Light: Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2018-063, CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications2018-03-26026 March 2018 CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications L-2018-067, Units 1 and 2 - Submittal of Joint Plant Access Shared Information Table2018-03-19019 March 2018 Units 1 and 2 - Submittal of Joint Plant Access Shared Information Table L-2018-030, Nuclear Energy Institute Commitments2018-03-0909 March 2018 Nuclear Energy Institute Commitments L-2018-064, NextEra Energy-Entergy Joint Composite Adversary Force2018-03-0808 March 2018 NextEra Energy-Entergy Joint Composite Adversary Force L-2017-212, Anchor Darling Double Disc Gate Valve Information and Status2017-12-21021 December 2017 Anchor Darling Double Disc Gate Valve Information and Status L-2017-200, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2017-12-13013 December 2017 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2017-145, CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature2017-08-28028 August 2017 CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature L-2017-121, Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography2017-07-24024 July 2017 Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography L-2017-118, Submittal of 10 CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature2017-06-28028 June 2017 Submittal of 10 CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature L-2017-122, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 21 Annual Submittal2017-06-28028 June 2017 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 21 Annual Submittal L-2017-095, Official Service List Changes2017-06-26026 June 2017 Official Service List Changes L-2017-104, Submittal of Report Pursuant to 10 CFR 71.95(a)(3) and (B) - Failure to Follow Conditions of TN-RAM Packaging Certificate of Compliance No. 92332017-06-15015 June 2017 Submittal of Report Pursuant to 10 CFR 71.95(a)(3) and (B) - Failure to Follow Conditions of TN-RAM Packaging Certificate of Compliance No. 9233 L-2017-014, Florida Power & Light Company - 10 CPR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications for 20162017-04-17017 April 2017 Florida Power & Light Company - 10 CPR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications for 2016 L-2017-040, Decommissioning Funding Status Reports/Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2017-03-30030 March 2017 Decommissioning Funding Status Reports/Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2017-051, Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2017-03-27027 March 2017 Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2016-216, Duane Arnold Energy Ctr., Point Beach Units 1 & 2, License Guarantees Payment of Deferred Premiums2016-12-0202 December 2016 Duane Arnold Energy Ctr., Point Beach Units 1 & 2, License Guarantees Payment of Deferred Premiums L-2016-188, Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f)2016-11-0303 November 2016 Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) L-2016-175, Units 1 and 2, Official Service List Changes and Distribution for Safeguards Information2016-08-30030 August 2016 Units 1 and 2, Official Service List Changes and Distribution for Safeguards Information 2024-01-25
[Table view] Category:Order Modifying License
MONTHYEARL-2019-155, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events2019-11-21021 November 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events L-2019-142, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions. L-2019-141, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation. NG-16-0120, FLEX Strategies Phase 2 Staffing Assessment2016-06-0303 June 2016 FLEX Strategies Phase 2 Staffing Assessment NG-15-0260, NextEra Energy Duane Arnold Energy Center, Llc'S Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events...2015-08-14014 August 2015 NextEra Energy Duane Arnold Energy Center, Llc'S Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events... ML12054A6942012-03-12012 March 2012 Issuance of Order to Modify Licenses with Regard to Reliable Hardened Containment Vents ML12054A6792012-03-12012 March 2012 Issuance of Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation ML12056A0452012-03-12012 March 2012 Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events ML12056A0442012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status ML12056A0432012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark II Containments ML12054A7352012-03-12012 March 2012 Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events NRC-2012-0068, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events2012-03-12012 March 2012 Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events NRC-2012-0067, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status NRC-2012-0069, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark Ii Containments2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark Ii Containments ML0616000762006-06-20020 June 2006 FRN: General Notice, EA-06-137 Enclosure, Order Modifying Licenses (Effective Immediately) ML0300603602003-01-0707 January 2003 Issuance of Order for Compensatory Measures Related to Access Authorization ML0228700082002-10-16016 October 2002 Enclosures 1 & 2, Order for Interim Safeguards & Compensatory Measures for Dry Independent Spent Fuel Storage Installation & Regulatory Issuance Summary 2002-12D 2019-08-08
[Table view] |
Text
NEXTeraM ENERGY. DUANE ARNOLD August 8, 2019 NG-19-0085 L-2019-142 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Duane Arnold Energy Center Docket No. 50-331 Renewed Facility Operating License No. DPR-49 NextEra Energy Duane Arnold. LLC's Request for Rescission of Commission Order EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions"
References:
- 1. Order EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions," dated June 6, 2013(ML13130A067)
- 2. NextEra Energy Duane Arnold, LLC, "Certification of Permanent Cessation of Power Operations," dated January 18, 2019 (ML19023A196)
On June 6, 2013, the Nuclear Regulatory Commission ("NRC" or "Commission") issued Order EA-13-109 (Reference 1) to Next Era Energy Duane Arnold, LLC (NEDA). A discussion of NEDA's implementation of the Order is included in the Enclosure.
By letter dated January 18, 2019 (Reference 2), NEDA provided formal notification to the NRC pursuant to 10 CFR 50.82(a)(1)(i) and 10 CFR 50.4(b)(8) of the intention to permanently cease power operations at the DAEC in the fourth quarter of 2020 .
The purpose of this letter is to request rescission of Order EA-13-109 upon docketing of the Title 10 Code of Federal Regulations (CFR) 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel. The enclosure to this letter provides the good cause justification for this request.
This letter contains no new regulatory commitments. If you have any questions regarding this submittal, please contact Michael Davis, Licensing Manager at 319-851-7032.
NextEra Energy Duane Arn old , LLC, 3277 DAEC Road , Palo , IA 523 24
Document Control Desk NG-19-0085 Page 2 of 2 I declare under penalty of perjury that the foregoing is true and correct.
Executed on August _8_, 2019.
Dean Curtland Site Director, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC Enclosure cc: Director, Office of Nuclear Reactor Regulation USNRC Regional Administrator Region Ill USNRC Project Manager, Duane Arnold Energy Center USNRC Resident Inspector, Duane Arnold Energy Center
Enclosure to NG-19-0085 NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions" 2 pages follow
Enclosure to NG-19-0085 - NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions" 1 Request for Order Rescission NextEra Energy Duane Arnold, LLC (NEDA) hereby submits a request that U.S.
Nuclear Regulatory Commission (NRG) Order EA-13-109, "Order Modifying Licensees with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions," be rescinded for the Duane Arnold Energy Center (DAEC) upon docketing of the Title 10 Code of Federal Regulations (CFR) 50.82(a)(1) certifications for permanent cessation of operation and permanent removal of fuel from the reactor vessel.
2 Background
On June 6, 2013, the NRG issued Order EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions," (Reference 1) to all licensees that operate boiling-water reactors with Mark I or Mark 11 containment designs. The Order was effective immediately and is applicable to DAEC. The Order required NEDA to install hardened containment venting systems that can be maintained functional during severe accident conditions (i.e., following significant core damage) and included two separate implementation phases. Phase 1 included modifications to wetwell venting systems, while Phase 2 included modifications to drywell venting systems or implementation of a reliable containment strategy that met regulatory approval.
By letter dated December 19, 2018 (Reference 2), NEDA notified the NRG, as required by Item IV. D.4 of Order EA-13-109, that full compliance with the requirements of the Order, for Phases 1 and 2, had been achieved for the DAEC.
By letter dated January 18, 2019 (Reference 3), NEDA provided formal notification to the NRG pursuant to 10 CFR 50.82(a)(1)(i) and 10 CFR 50.4(b)(8) of the intention to permanently cease power operations at the DAEC in the fourth quarter of 2020.
Consequently, NEDA requests the requirements of NRG Order EA-13-109 be rescinded for DAEC upon docketing of the 10 CFR 50.82(a)(1) certifications for permanent cessation of operation and permanent removal of fuel from the reactor vessel.
Order EA-13-109,Section IV.D., states that "the Director, Office of Nuclear Reactor Regulation may, in writing, relax or rescind any of the above conditions upon demonstration by the Licensee of good cause."
3 Basis for Rescission Request Upon docketing of the 10 CFR 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel, the 10 CFR Part 50 license will no longer authorize operation of the reactor or emplacement or retention of fuel into the reactor vessel.
1
Enclosure to NG-19-0085 - NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions" With permanent removal of fuel from the reactor vessel, the function of primary containment will cease. Primary containment has no design function regarding protection of the fuel in the Spent Fuel Pool (SFP), or mitigation of SFP accident scenarios. Therefore, implementation of the requirements in Order EA-13-109 will no longer have any nexus to reasonable assurance of adequate protection of the public health and safety.
The proposed request is similar to those approved by the NRC for the permanently shut down and defueled Vermont Yankee Nuclear Power Station (ML14055A323),
Oyster Creek Nuclear Generating Station (ML18176A068), and Pilgrim Nuclear Power Station (ML19094A533).
4 Conclusion Based on the above, the Director, Office of Nuclear Reactor Regulation is requested to rescind Order EA-13-109 for DAEC upon docketing of the 10 CFR 50.82(a)(1) certifications for permanent cessations of operations and permanent removal of fuel from the reactor vessel.
5 References
- 1. NRC Order Number EA-13-109, "Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions" dated June 6, 2013(ML13130A067).
- 2. NextEra Energy Duane Arnold, LLC, "Completion of Required Action for NRC Order Number EA-13-109, Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions," dated December 19, 2018 (ML18360A170).
- 3. NextEra Energy Duane Arnold, LLC, "Certification of Permanent Cessation of Power Operations," dated January 18, 2019(ML19023A196).