L-17-285, Summary of Changes to Data Point Library

From kanterella
Jump to navigation Jump to search
Summary of Changes to Data Point Library
ML17257A189
Person / Time
Site: Beaver Valley
Issue date: 08/23/2017
From:
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
References
L-17-285
Download: ML17257A189 (16)


Text

)

/

I Attachment L-17-285 Summary of Changes to Data Point Library Page 1 Reactor Unit DPL Point Description of Change(s)

Create new point named R0019A_2 with same fields as XR041_2.

BV2 R0019A 2 Date: changed to "8/23/17", Data Feeder: changed to "PCS" Create new point named R0020A_2 with same fields as XR042_2.

BV2 R0020A 2 Date: changed to "8/23/17", Data Feeder: changed to "PCS" Create new point named R0015A_2 with same fields as XR045_2.

BV2 R0015A 2 Date: changed to "8/23/17", Data Feeder: changed to "PCS" Create new point named R0093A_2 with same fields as XR046_2. Date: changed to BV2 R0093A 2 "8/23/17", Data Feeder: changed to "PCS", Units: changed to "uCi/S" Create new point named R0091A_2 with same fields as XR053_2. Date: changed to BV2 R0091A 2 "8/23/17", Data Feeder: changed to "PCS", Units: changed to "uCi/S" Create new point named R0098A_2 with same fields as XR054_2. Date: changed to BV2 R0098A 2 "8/23/17", Data Feeder: changed to "PCS", Units: changed to "uCi/S" Create new point named R0099A_2 with same fields as XR055_2. Date: changed to BV2 R0099A 2 "8/23/17", Data Feeder: changed to "PCS", Units: changed to "uCi/S" Date: changed to "8/23/17"

.. Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XR041 2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "8/23/17" Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XR042 2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "8/23/17" Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XR046 2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "8/23/17" Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XR045-'-2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "8/23/17" Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XR053_2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "8/23/17" )

Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XROS4 2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

Date: changed to "8/23/17" Unique System Desc.: "Point deleted per ECP-14-0466" BV2 XROS5_2 Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.

/

/ Enclosure L-17-285 Beaver Valley Power Station EROS Data Point Library, Updated Pages

( 14 pages follow)

/ BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRC EROS Parameter:

Point ID: XR041 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-75

I BEAVER VALLEY POWER STATION EADS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRC EROS Parameter:

Point ID: XR042 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

AlarmfTrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-76

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRG EROS Parameter:

Point ID: XR045 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm!Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-77

_J

/

I

/

BEAVER VALLEY POWER STATION EADS DAT A POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRG EROS Parameter:

Point ID: XR046 Plant Spec Point besc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

AlarmfTrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-78

! BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRC EROS Parameter:

Point ID: XR053 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm!Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-79

/' BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRG EADS Parameter:

Point ID: XR054 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minif!lum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm!Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-80

I BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: ARERAS NRC EROS Parameter:

Point ID: XROSS Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarmffrip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.: Point deleted per ECP-14-0466 2-81

/ BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRC EROS Parameter: EFF-GAS-RAD1 Point ID: R0019A Plant Spec Point Desc.: 2HVS-RQl101A Generic/Cond Desc.: RADIOACTIVITY OF RELEASED PARTIC Analog/Digital: A' Engr Units/Dig States: uCi/cc Engr Units Conversion: N/A Minimum Instr Range: 3.24E-10 Maximum Instr Range: 3.24E-4 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: P Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points: HIGH 9.71 E-5 uCi/cc >BACKGROUND NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-ON Power Level: N/A Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: N/A Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQl101 A monitors the airborne activity between the discharge of the Leak Collection Normal Exhaust Fans and the Ventilation Vent. A High activity signal will isolate the Purge System and indicate to the operator the need to divert flow through the Filter Banks.

Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 2-82

)

J

/

BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRC EROS Parameter: EFF-GAS-RAD2 Point ID: R0020A Plant Spec Point Desc.: 2HVS-RQl101B Generic/Cond Desc.: RADIOACTIVITY OF RELEASED GASSES Analog/Digital: A Engr Units/Dig States: uCi/cc Engr Units Conversion: N/A Minimum Instr Range: 3.7E-7 Maximum Instr Range: 0.372 Zero Point

Reference:

O Reference Point Notes: N/A PROC or SENS: P Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points: HIGH 1.81 E-4 uCi/cc >BACKGROUND NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-ON Power Level: N/A Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: N/A Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQl101 B monitors the airborne activity between the discharge of the Leak Collection Normal Exhaust Fans and the Ventilation Vent. A High activity signal will isolate the Purge System and indicate to the operator the need to divert flow through the Filter Banks.

Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484.

2-83

J BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRG EROS Parameter: EFF-GAS-RAD3 Point JD: R0015A Plant Spec Point Desc.: 2HVS-RQl109A Generic/Cond Desc.: RADIOACTIVITY OF RELEASED PARTIC Analog/Digital: A Engr Units/Dig States: uCi/cc Engr Units Conversion: N/A Minimum Instr Range: 3.24E-10 Maximum Instr Range: 3.24E-4 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: S Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD AlarmfTrip Set Points: HIGH 2.59E-4 uCi/cc >BACKGROUND NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-ON Power Level: NIA Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: NIA Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQl109A monitors the airborne activity between the discharge of the Leak Collection Filter Exhaust Fans and the Elevated Release Exhaust Line. This sample is composed of effluent from the Auxiliary and Fuel Buildings, after it has passed through Main Filter Banks in the SLCRS system before being discharged to atmosphere. Note:

The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-2; Calculation Package ERS-SFL-92-024; CR 04-05484.

2-84

I J BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRC EROS Parameter: EFF-GAS-RAD4 Point ID: R0093A Plant Spec Point Desc.: 2HVS-RQl109 Generic/Cond Desc.: RADIOACTIVITY OF RELEASED GASSES Analog/Digital: A Engr Units/Dig States: uCi/S Engr Units Conversion: NIA Minimum Instr Range: 2.5E-7 Maximum Instr Range: 8.9E+4 Zero Point

Reference:

0 Reforence Point Notes: N/A PROC or SENS: P Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-ON Power Level: N/A Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: N/A

. Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. This is a multi-range monitor. Lowest onscale channel report. 2HVS-RQl109B, C and D monitors the gaseous activity between the discharge of the leak collection filter exhaust fans and the elevated release exhaust line. This sample is composed of effluent from the Auxiliary and Fuel Buildings, after it has passed through the Main Filter Banks in the SLCRS system before being discharged to atmosphere. Note The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref Calculation Package ERS-SFL-92-024 CR 04-05484 2-85

)

(

(

.i J

J BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRG EROS Parameter: EXTRA9 Point ID: R0091A Plant Spec Point Desc.: 2MSS-RQl101 A Generic/Cond Desc.: RADIOACTIVITY OF RELEASED GASSES Analog/Digital: A Engr Units/Dig States: uCi/S Engr Units Conversion: N/A Minimum Instr Range: 2.5E-3 Maximum Instr Range: 2.5E3 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: P Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-ON Power Level: N/A Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: N/A Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.

2-86

I BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRG EROS Parameter: EXTRA 10 Point ID: R0098A Plant Spec Point Desc.: 2MSS-RQl101B Generic/Cond Desc.: RADIOACTIVITY OF RELEASED GASES Analog/Digital: A Engr Units/Dig States: uCi/S Engr Units Conversion: N/A Minimum Instr Range: 2.5E-3 Maximum Instr Range: 2.5E3 Zero Point

Reference:

0 Reference Point Notes: NIA PROC or SENS: p Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-ON Power Level: N/A Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: N/A Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.

2-87

/

BEAVER VALLEY POWER STATION I EROS DATA POINT LIBRARY Date: 8/23/2017 Reactor Unit: BV2 Data Feeder: PCS NRG EADS Parameter: EXTRA 11 Point ID: R0099A Plant Spec Point Desc.: 2MSS-RQl101C Generic/Cond Desc.: RADIOACTIVITY OF RELEASED GASSES Analog/Digital: A Engr Units/Dig States: uCi/S Engr Units Conversion: N/A Minimum Instr Range: 2.5E-3 Maximum Instr Range: 2.5E3 Zero Point

Reference:

O Reference Point Notes: N/A PROC or SENS: P Number of Sensors:

How Processed: N/A Sensor Location: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A Nl Detector Power Supply Turn-ON Power Level: N/A Instrument Failure Mode: DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters: N Level Reference Leg: N/A Unique System Desc.: 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.

2-88