IR 05000461/1987038

From kanterella
Jump to navigation Jump to search
Partially Withheld Physical Security Insp Rept 50-461/87-38 on 871130-1204 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Security Plan/Implementing Procedures, Security Organization & Program Audit & Physical Barriers
ML20238C477
Person / Time
Site: Clinton Constellation icon.png
Issue date: 12/22/1987
From: Creed J, Drouin B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20238C473 List:
References
50-461-87-38, NUDOCS 8712310035
Download: ML20238C477 (1)


Text

~ _ _

. -

,'

.

,

U. S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-461/87038(DRSS)

Docket No. 50-461 License No. NPF-55 Licensee:

Illinois Power Company 500 South 27th Street Decatur, IL 62525 Inspection At:

Clinton Power Station, Clinton, Illinois l

Inspection Conducted:

November 30 through December 4, 1987 i

'

Date of Previous Security Inspection: August 10-14, 1987 Type of Inspectionpu.nannounced Physical Security Inspection Inspector:

G/22./6

'

'

,

B MVoutii Datt

'

Physical Security Inspector l

Approved By:

S k MN'l hoV M/h/F7

'

J. R. Creed, Chief Date i

Safeguards Section

!

l Inspection Summary

l Inspection on November 30 through December 4, 1987 (Report

'

No. 56-461/87038(DRSS))-

~4reas Inspected:

Security Plan / Implementing Procedures; Management Effectiveness; Security Organization; Security Program Audit; Records and Reports; Testing and Maintenance; Physical Barriers - Protected and Vital Aceas; Security System Power Supply; Lighting; Compensatory Measures;

!

i Assessment Aids; Access Control-Personnel, Packages and Vehicles; Detection l

Aids - Protected Area; Alarm Stations; Personnel Training and Qualifications;.

Safeguards Contingency Plan and Licensee action on previous findings.

Results: The licensee was determined to be in compliance with NRC requirements in all 19 inspected areas. One previous inspection finding was closed.

The licensee is achieving acceptable progress in reducing their alarm rate, l

l however, the remaining inspection finding (alarm rate) will remain open.

(Details:

UNCLASSIFIED )

Enclosure contains Upon separation this.

page is Decontrolled 8712310035 871228

gDR ADOCK 05000461 DCD

'

-

__________-_____2________--_____-____-________