Security Baseline Inspection Report 05000424/2022402, 05000425/2022402 and 07201039/2022401
ML22179A273
Person / Time
Site: Vogtle, 07201039  
(NPF-068, NPF-081)
Issue date: 07/05/2022
From: Jannette Worosilo
NRC/RGN-II/DRS/PSB1
To: Gayheart C
Southern Nuclear Operating Co
Richardson A
References
IR 2022402
Download: ML22179A273 (10)


Text

June 29, 2022

SUBJECT:

VOGTLE NUCLEAR GENERATING PLANT, UNITS 1&2 - SECURITY BASELINE INSPECTION REPORT 05000424/2022402, 05000425/2022402 AND 07201039/2022401

Dear Ms. Gayheart:

On June 9, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Vogtle Nuclear Generating Plant, Units 1&2 and discussed the results of this inspection with Mr.

Ho Nieh and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Jannette G. Worosilo, Chief Plant Support Branch Division of Reactor Safety Docket Nos. 05000424,05000425, and 07201039 License Nos. NPF-68 and NPF-81

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000424, 05000425, and 07201039

License Numbers:

NPF-68 and NPF-81

Report Numbers:

05000424/2022402, 05000425/2022402 and 07201039/2022401

Enterprise Identifier:

I-2022-402-0022, I-2022-401-0044

Licensee:

Southern Nuclear Operation CO, INC

Facility:

Vogtle Nuclear Generating Plant, Units 1&2

Location:

Waynesboro, GA

Inspection Dates:

June 06, 2022 to June 09, 2022

Inspectors:

R. Patterson, Physical Security Inspector

J. Tornow, Physical Security Inspector

J. Wallo, Senior Physical Security Inspector

Approved By:

Jannette G. Worosilo, Chief

Plant Support Branch

Division of Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a security baseline inspection at Vogtle Nuclear Generating Plant,

Units 1&2, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

SAFEGUARDS

71130.02 - Access Control

The inspectors evaluated the access control program through completion of the following

inspection elements: Access Control

(1) Tier I: All Requirements

Tier II: (02.06 a - d, 02.07 a, 02.08 a, b, e)

Tier III: (02.09)

71130.04 - Equipment Performance, Testing, and Maintenance

The inspectors evaluated the security equipment testing and maintenance program. The following elements were evaluated from this IP:

Equipment Performance, Testing, and Maintenance (1 Sample)

(1) Tier I: All Requirements

Tier II: (02.09 a, b, 02.11 a-c, 02.12 a, 02.13 a)

Tier III: (02.14, 02.15 a-c)

71130.07 - Security Training

The inspectors evaluated the security training program through completion of the following

procedure elements: Security Training

(1) Tier I: All Requirements

Tier II: (02.05 b, c, 02.06 a, b, 02.07 a, 02.09 b)

Tier III: (02.10, 02.11 a, 02.12 a, 02.13 a, b)

71130.09 - Security Plan Changes

The inspectors evaluated the security plan changes through completion of the following

procedure elements: Security Plan Changes

(1)

Review Security Plan Changes (IP Section 02.01) (1 Sample)

The opportunity to apply this procedure was not available in accordance with Inspection Manual Chapter 0306. This sample was not available because the licensee did not conduct the activity covered by this IP. Specifically, the licensee has not initiated a physical security plan change in accordance with 10 CFR 50.54(p)(2)since the last performance of this IP.

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

PP01: Protected Area Security Equipment Performance Index Sample (IP Section 02.17) (1 Sample)

(1) May 2021 through May

OTHER ACTIVITIES

- TEMPORARY INSTRUCTIONS, INFREQUENT AND ABNORMAL 81311 - Physical Security Requirements for Independent Spent Fuel Storage Installations Physical Security Requirements for Independent Spent Fuel Storage Installations===

(1) All inspection requirements for this IP dated October 6, 2020 were completed.

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On June 9, 2022, the inspectors presented the security baseline inspection results to Mr.

Ho Nieh and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71130.02

Procedures

00008-C

Plant Lock and Key Control

Version 19.1

71130.02

Procedures

00652-C

Personnel Escort Duties and Responsibilities

Version 12.0

71130.02

Procedures

00653-C

Protected Area Entry/Exit Control

Version 25.0

71130.02

Procedures

90007-C

Security Designee List

Version 12.0

71130.02

Procedures

NMP-AD-005

Insider Mitigation Program/Access Authorization

Version 3.1

71130.02

Procedures

NMP-SE-021

Security Search Process

Version 11.0

71130.02

Procedures

NMP-SE-022

Fleet Access Outage In-Processing

Version 1.0

71130.02

Procedures

NMP-SE-023

Personnel Authorization and Badging Program

Version 5.0

71130.02

Self-Assessments Audit Report

Fleet SEC-2022

Nuclear Oversight Audit of Security

May 2022

71130.04

Corrective Action

Documents

10808615

Central Alarm Station Base Radio Defective

6/25/2021

71130.04

Corrective Action

Documents

10846542

Loss of all Color and Thermal cameras at two locations.

2/13/2021

71130.04

Corrective Action

Documents

10848374

ISFSI IDS Zone locked in alarm

1/4/2022

71130.04

Corrective Action

Documents

10854849

MUX IO Panel Trouble Alarm

1/30/2022

71130.04

Corrective Action

Documents

10867502

Broken Rifle / Non KPI

3/17/2022

71130.04

Corrective Action

Documents

10870858

Unsecure VA Door

4/2/2022

71130.04

Corrective Action

Documents

Resulting from

Inspection

10887512

Equipment testing criteria

6/13/2022

71130.04

Procedures

90013-C

Patrol Duties and Surveillance

Rev. 26.0

71130.04

Procedures

202-C

Testing Explosive Detector Units

Rev. 20

71130.04

Procedures

203-C

Metal Detector Testing

Rev. 19

71130.04

Procedures

204-C

X Ray Equipment Test Procedure

Rev. 16.0

71130.04

Procedures

205-C

Day Testing of the Security Perimeter and Duress

Alarm Systems

Rev. 42

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71130.04

Procedures

206-C

Protected Area Lighting System

Rev. 15.0

71130.04

Procedures

207-C

Security Barrier Inspection

Rev. 22

71130.04

Procedures

207-C

Security Barrier Inspection

71130.04

Procedures

90318-C

Testing and Maintenance of Security Personnel

Equipment

Rev. 21.1

71130.07

Corrective Action

Documents

21-10798907

71130.07

Corrective Action

Documents

21-10801620

71130.07

Corrective Action

Documents

21-10802132

71130.07

Corrective Action

Documents

21-10806861

71130.07

Corrective Action

Documents

21-10809408

71130.07

Corrective Action

Documents

21-10817385

71130.07

Corrective Action

Documents

21-10847000

71130.07

Corrective Action

Documents

2-10863510

71130.07

Corrective Action

Documents

2-10870136

71130.07

Corrective Action

Documents

2-10878055

71130.07

Corrective Action

Documents

2-10878314

71130.07

Corrective Action

Documents

2-10878978

71130.07

Corrective Action

Documents

2-10880100

71130.07

Corrective Action

Documents

2-10881094

71130.07

Corrective Action

10887518

Training Qualification Cover Sheet

6/13/2022

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Documents

Resulting from

Inspection

71130.07

Miscellaneous

Daylight Rifle (223) course

February 21,

20

71130.07

Miscellaneous

Night Fire (5.56) Course

June 15,

21

71130.07

Procedures

Rifle Thermal Use-Insight C.R.A.T.

O.S

June 9Property "Contact" (as page type) with input value "O.S</br></br>June 9" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process., 2022

71130.07

Procedures

Rifle Thermal Use-CNVD-T

January 1,

2017

71130.07

Procedures

00055-C

Sabotage or Malfeasance

Version 10.0

71130.07

Procedures

00655-C

Bombs or Other Overt Threats

Version 15.0

71130.07

Procedures

90321-C

Threat Assessment and Security Force Protection

Recommendations

Version 5.1

71130.07

Procedures

ACAD-91-006

Guidelines for On-the-Job Training and Evaluation

Revision 4

71130.07

Procedures

NIS-TR-02

On-The-Job Training and Task Performance Evaluation

Process

Revision 0

71130.07

Procedures

NMP-SE-008

Use of Force

Version 4.2

71130.07

Procedures

NMP-SE-020

SNC Security Training Program

Version 4.0

71130.07

Procedures

NMP-SE-020-002

Graded Systematic Approach to Security Training (GSAST)

Version 3.0

71130.07

Procedures

NMP-SE-020-004

Qualifications Requirements for Security Positions

Version 4.0

71130.07

Procedures

NMP-TR-209

Interface Documents for NISP-TR-Procedures

Version 8.0

71130.07

Procedures

S-SE-LM-104-19

Tactical Qualification Course

Revision 0

71130.07

Procedures

S-SE-LM-Task 22

Security Physical Fitness Test

March 17,

21

71130.07

Procedures

S-SE-LP-11300-

Legal Requirements for SNC Security Officers

March 7,

2016

71151

Procedures

NMP-AD029

Preparation and Reporting of Regulatory Assessment

Performance Indicator Data and the Monthly Operations

Report

Version 3.1

81311

Corrective Action

Documents

Resulting from

Inspection

10887507

ISFSI Response

6/13/2022