IR 05000424-14-502 and 05000425-14-502; 05/19/2014 - 05/23/2014; Vogtle Electric Generating Plant, Units 1 and 2; Emergency Preparedness Baseline Inspection
ML14161A665
Person / Time
Site: Vogtle  
Issue date: 06/09/2014
From: Brian Bonser
NRC/RGN-II/DRS/PSB1
To: Tynan T
Southern Nuclear Operating Co
Linda K. Gruhler 404-997-4633
References
IR-14-502
Download: ML14161A665 (11)


Text

June 9, 2014

SUBJECT:

VOGTLE ELECTRIC GENERATING PLANT - U.S. NUCLEAR REGULATORY COMMISSION EMERGENCY PREPAREDNESS INSPECTION REPORT 05000424/2014502 AND 05000425/2014502

Dear Mr. Tynan:

On May 23, 2014, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Vogtle Electric Generating Plant, Units 1 and 2. The enclosed inspection report documents the inspection results that were discussed on May 23, 2014, with Mr. G. Gunn and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations, and with the conditions of your license. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

No findings were identified during this inspection.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's

"Rules of Practice," a copy of this letter, its Enclosure, and your response, if any, will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Brian Bonser, Chief Plant Support Branch 1 Division of Reactor Safety

Docket Nos. 50-424 and 50-425 License Nos. NPF-68 and NPF-81

Enclosure:

Inspection Report 05000424/2014502 and 05000425/2014502 w/Attachment: Supplementary Information

REGION II==

Docket Nos:

05000424 and 05000425

License Nos:

NPF-68 and NPF-81

Report Nos:

05000424/2014502 and 05000425/2014502

Licensee:

Southern Nuclear Operating Company, Inc.

Facility:

Vogtle, Units 1 and 2

Location:

Waynesboro, GA

Dates:

May 19 - 23, 2014

Inspectors:

M. Speck, Senior Emergency Preparedness Inspector

S. Sanchez, Senior Emergency Preparedness Inspector

L. Cain, Senior Resident Inspector

C. Fontana, Emergency Preparedness Inspector

T. Chandler, Resident Inspector

R. Patterson, Physical Security Inspector

Approved by:

Brian Bonser, Chief Plant Support Branch 1 Division of Reactor Safety

SUMMARY OF FINDINGS

Inspection Report (IR) 05000424/2014502 and 05000425/2014502; 05/19/2014 - 05/23/2014;

Vogtle Electric Generating Plant, Units 1 and 2; Emergency Preparedness Baseline Inspection.

The report covered an announced inspection by three emergency preparedness inspectors, one senior resident inspector, one resident inspector, and one security inspector. No findings were identified. The NRCs program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process.

REPORT DETAILS

REACTOR SAFETY

Cornerstone: Emergency Preparedness

1EP4 Emergency Action Level and Emergency Plan Changes

a. Inspection Scope

Since the last NRC inspection of this program area, no changes were made to the Radiological Emergency Plan (REP). The licensee implemented version 4 to NMP-EP-110-GL03, Vogtle Plant Emergency Action Levels (EALs), and made several changes to emergency plan (E-Plan) implementing procedures, and determined that in accordance with 10 CFR 50.54(q), the changes made in these revisions resulted in no reduction in the effectiveness of the Plan, and the Plan continued to meet the requirements of 10 CFR 50.47(b) and Appendix E to 10 CFR Part 50. The inspectors reviewed a sampling of the implementing procedure changes made between November 2013 and May 2014 to evaluate for potential reductions in the effectiveness of the Plan.

However, this review was not documented in a Safety Evaluation Report (SER) and does not constitute formal NRC approval of the changes. Therefore, these changes remain subject to future NRC inspection in their entirety.

The inspection was conducted in accordance with NRC Inspection Procedure (IP)71114, Attachment 04, Emergency Action Level and Emergency Plan Changes. The applicable planning standards of 10 CFR 50.47(b), and its related requirements in 10 CFR 50, Appendix E, were used as reference criteria.

The inspectors reviewed various documents that are listed in the Attachment to this report. This inspection activity satisfied one inspection sample for the EAL and E-Plan changes on an annual basis.

b. Findings

No findings were identified.

1EP7 Exercise Evaluation - Hostile Action Event

a. Inspection Scope

Title 10 CFR 50, Appendix E,Section IV.F.2.j, requires in part that, nuclear power reactor licensees, in each 8-calendar-year exercise cycle, provide the opportunity for their emergency response organization (ERO) to demonstrate proficiency in the key skills necessary to respond to a hostile action (HA) directed at the plant site. The licensee designed the May 21, 2014, exercise to satisfy that requirement; the NRC inspected the HA event exercise to assess the licensees ability to effectively implement their E-Plan during an HA event, and adequately protect public health and safety.

The exercise evaluation consisted of the following reviews and assessments:

  • The adequacy of the licensees performance in the biennial exercise, conducted on May 21, 2014, was reviewed and assessed regarding the implementation of the Risk Significant Planning Standards (RSPS) in 10 CFR 50.47 (b)(4), (5), (9), and (10),which address emergency classification, offsite notification, radiological assessment, and protective action recommendations, respectively.
  • The overall adequacy of the licensees emergency response facilities with regard to NUREG-0696, Functional Criteria for Emergency Response Facilities, and E-Plan commitments. The facilities assessed were the Control Room Simulator, simulated Central Alarm and Secondary Alarm Stations (CAS/SAS), Alternative Facility, Incident Command Post (ICP), and the Emergency Operations Facility (EOF).
  • A review of other performance areas, such as, the ERO recognition of abnormal plant conditions; command and control, including interactions with site security staff, intra-and inter-facility communications; prioritization of mitigation activities; utilization of repair and field monitoring teams; interface with offsite agencies, including local law enforcement agencies; staffing and procedure adequacy; and the overall implementation of the E-Plan and its implementing procedures.
  • Past performance issues from NRC inspection reports and Federal Emergency Management Agency (FEMA)/Department of Homeland Security (DHS) exercise reports to determine the effectiveness of corrective actions as demonstrated during this exercise to ensure compliance with 10 CFR 50.47(b)(14).
  • The adequacy of the licensees post-exercise critiques, to evaluate licensee self-assessment of its ERO performance during the May 21, 2014, exercise to ensure compliance with 10 CFR 50, Appendix E, Subsection IV.F.2.g.

The inspectors reviewed various documents which are listed in the Attachment. This inspection activity satisfied one inspection sample for the exercise evaluation on a biennial basis.

b. Findings

No findings were identified.

1EP8 Exercise Evaluation - Scenario Review

a. Inspection Scope

Prior to the inspection activity, the inspectors conducted an in-office review of the

exercise objectives and scenario submitted to the NRC using IP 71114.08, Exercise

Evaluation - Scenario Review, to determine if the exercise would test major elements

of the E-Plan as required by 10 CFR 50.47(b)(14).

The inspectors reviewed various documents which are listed in the Attachment to this report. This inspection activity satisfied one inspection sample for the exercise valuation on a biennial basis.

b. Findings

No findings were identified

OTHER ACTIVITIES

4OA1 Performance Indicator Verification

a. Inspection Scope

The inspectors sampled licensee submittals relative to the Performance Indicators (PIs)listed below for the period January 1, 2013, through March 31, 2014. To verify the accuracy of the PI data reported during that period, PI definitions and guidance contained in Nuclear Energy Institute (NEI) 99-02, Regulatory Assessment Performance Indicator Guideline, Revision 7, was used to confirm the reporting basis for each data element.

Emergency Preparedness Cornerstone

  • Emergency Response Organization Drill/Exercise Performance (DEP)
  • Emergency Response Organization Readiness (ERO)
  • Alert and Notification System Reliability (ANS)

For the specified review period, the inspectors examined data reported to the NRC, procedural guidance for reporting PI information, and records used by the licensee to identify potential PI occurrences. The inspectors verified the accuracy of the DEP through review of a sample of drill and event records. The inspectors reviewed selected training records to verify the accuracy of the ERO PI for personnel assigned to key positions in the ERO. The inspectors verified the accuracy of the PI for ANS reliability through review of a sample of the licensees records of periodic system tests. Licensee procedures, records, and other documents reviewed within this inspection area are listed in the Attachment.

This inspection activity satisfied one inspection sample for each of the three Emergency Preparedness PIs (i.e., DEP, ERO, and ANS) on an annual basis.

b. Findings

No findings were identified.

4OA6 Meetings, Including Exit

On May 23, 2014, the lead inspector presented the inspection results to Mr. G. Gunn and other members of the plant staff. The inspectors confirmed that proprietary information was not provided during the inspection.

ATTACHMENT:

SUPPLEMENTARY INFORMATION

KEY POINTS OF CONTACT

Licensee personnel

T. Tynan, Site Vice President
R. Barringer, Security Manager
M. Brett, Emergency Preparedness Specialist
G. Gunn, Regulatory Affairs Manager (Acting)
J. Hall, Emergency Preparedness Supervisor (Units 3 and 4)
M. Hayden, Emergency Preparedness Supervisor
R. Kidwell, Emergency Preparedness contractor
S. Odom, Corporate Emergency Preparedness Coordinator
C. Smith, Emergency Preparedness Specialist
S. Waldrup, Regulatory Affairs Manager

ITEMS OPENED, CLOSED, DISCUSSED, AND UPDATED

None

LIST OF DOCUMENTS REVIEWED