~ PRIOZn Y Z REGULATORY<'XM'MRKF68IM$9lRKBQTION SYSTEM (RIDS)

ACCESSION NBR:9503200023 DOC.DATE: 95/03/13 NOTARIZED: NO DOCKET ¹ FACIL:50-387 Susquehanna Steam Electric Station, Unit 1, Pennsylva 05000387 50-388 Susquehanna Steam Electric Station, Unit 2, Pennsylva 05000388 AUTH.NAME AUTHOR AFFILIATION WHITEFJ.R.

Region 1 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION BYRAM,R.G.

Pennsylvania Power

& Light Co.

SUBJECT:

Forwards insp repts SO-387/95-02

& 50-388/95-02 on 950101-0213.No violations noted.

DISTRIBUTION CODE:- IE01D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response NOTES:'5000387 P

RECIPIENT ID CODE/NAME PD1-2 PD INTERNAL: ACRS AEOD/SPD/RAB AEODQTTC

~FIEE CENT~ER

NRR/DORS/OEAB NUDOCS-ABSTRACT OGC/HDS2 EXTERNAL: LITCO BRYCEFJ H

NRC PDR NOTES:

COPIES LTTR ENCL

1

2

1

1

1

-

1

1

1

1

1

RECIPIENT ID CODE/NAME POSLUSNYFC AEOD/DEIB AEOD/SPD/RRAB DEDRO NRR/DISP/PIPB NRR/DRCH/HHFB OE DIR RGN1 FILE

NOAC COPIES LTTR ENCL

1

1

1

1

1

1

1

1

1 D

C OTE TO ALL"RIDS" RECIPIENTS:.

PL EASE HELP US TO REDUCE WASTE! CONTACTTHE DOCL'MEiTCONTROL DESK, ROONI PI-37 (EXT. 504.00S3

SUBJECT:

NRC REGION I COMBINED INSPECTION 50-387/95-02; 50-388/95-02

Dear Mr. Byram:

The enclosed report documents a resident safety inspection conducted by Ms. H.

Banerjee, Mr. D. J. Mannai, and others from January 1,

1995 through February 13, 1995, at the Susquehanna Steam Electric Station (SSES),

Salem Township, Pennsylvania.

Areas relevant to the health and safety of the public examined during the inspection are described in the enclosed report.

At the conclusion of the inspection, Ms M. Banerjee, Senior Resident Inspector, summarized the inspection findings with Hr.

G. J. Kuczynski and other members of your staff.

Identification and resolution-of the engineering deficiency report related to the high pressure core injection system reflected a good questioning attitude and capability, and is considered a strength of the engineering organization.

Your identification of a need for and enhancement of guidance on operability determination is expected to improve the timeliness of the process.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of this letter and its enclosures will be placed in the NRC Public Document Room.

Your cooperation with us in this matter is appreciated.

Sincerely, ORIGINAL SIGNED BY:

John R. Mhite, Chief, Reactor Projects, Section 2A Docket Nos. 50-387;50-388 Enclosure:

1.

Combined NRC Inspection Report 50-387/95-02; 50-388/95-02 9503200023 9503i3 PDR ADOCK 05000387

PDR

cc w/encl:

H.

G. Stanley, Vice President Nuclear Operations G. T; Jones, Vice President - Nuclear Engineering J.

M. Kenny, Nuclear Licensing M. M. Urioste, Nuclear Services Manager, General Electric C.

D. Lopes, Manager - Nuclear Security W.

E. Burchill, Manager, Nuclear Assessment Services

.

J.

M. Finnegan, Supervisor, Nuclear Compliance H. D. Moodeshick, Special Office of the President J.

C. Tilton, III, Allegheny Electric Cooperative, Inc.

PUBLIC Nuclear Safety Information Center (NSIC)

D. Screnci, PAO (2)

NRC Resident Inspector Commonwealth of Pennsylvania

bcc w/encl:

Region I Docket Room (with concurrences)

K. Gallagher, DRP bcc w/encl (Via E-Mail:

W. Dean, OEDO C. Poslusny, Project Manager, NRR J. Stolz, PDI-2, NRR M. Shannon, ILPB Chief, Reactor Systems Branch, Division of Systems Safety and Analysis, NRR DOCUMENT NAME:

a:9502.sus To neehe a oopy of thts attachment/enctosure OFFICE RI

'AME MB e

DATE

01/

tndtcate ln the bee 'C ~ Copy wtthout attachment/enctosure

'E ~ Copy wtth py RI:DRP

/95 0 FICIAL RECORD COPY