Design Basis Assurance Inspection (Programs) Inspection Report 05000348/2025010 and 05000364/2025010
ML25100A185
Person / Time
Site: Farley  
Issue date: 04/14/2025
From: Renee Taylor
NRC/RGN-II/DORS
To: Coleman J
Southern Nuclear Operating Co
References
IR 2025010
Download: ML25100A185 (8)


Text

SUBJECT:

JOSEPH M. FARLEY NUCLEAR PLANT - DESIGN BASIS ASSURANCE INSPECTION (PROGRAMS) INSPECTION REPORT 05000348/2025010 AND 05000364/2025010

Dear Jamie M. Coleman:

On April 2, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Joseph M. Farley Nuclear Plant and discussed the results of this inspection with Gene Surber, Licensing Manager, and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Ryan C. Taylor, Chief Engineering Branch 1 Division of Operating Reactor Safety Docket Nos. 05000348 and 05000364 License Nos. NPF-2 and NPF-8

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000348 and 05000364

License Numbers:

NPF-2 and NPF-8

Report Numbers:

05000348/2025010 and 05000364/2025010

Enterprise Identifier:

I-2025-010-0028

Licensee:

Southern Nuclear Operating Company, Inc.

Facility:

Joseph M. Farley Nuclear Plant

Location:

Columbia, AL

Inspection Dates:

February 24, 2025 to April 02, 2025

Inspectors:

L. Colon Fuentes, Construction Project Inspector

M. Riley, Senior Project Engineer

T. Su, Senior Reactor Inspector

Approved By:

Ryan C. Taylor, Chief

Engineering Branch 1

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a design basis assurance inspection (programs) inspection at Joseph M. Farley Nuclear Plant, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.21N.03 - Commercial Grade Dedication Commercial Grade Dedication

(1) Item 536643, Arm Damper Crank for 1/2 in. Diameter Damper Shaft
(2) Item Master 596403, MOV Long Life Grease
(3) Item Master 1422618, DC Power Supply Input Voltage 117 +/- 10% VAC Output 45VDC at 100mA
(4) Item Master 1363889, Transformer Control 120/24 VAC 30 VA
(5) Item Master 511918, Switch Auxiliary Assembly 16 Stage Siemens Type Q-10 MOC
(6) Item 546647, Dynamic Pneumatic Actuator
(7) Item Master 599832, Low Pressure Cutout Pressure Switch
(8) Item Master 549512, Scroll Compressor
(9) Item Master 537988, Breaker Circuit Molded Case 3 Pole 25 Amp 600 Volt AC Rated Magnetic (Instantaneous) Only
(10) Item Master 589831, SCT Isolation Converter 4-20mA DC to 4-20mA DC
(11) Item Master 548877, BF Relay Control 300VAC Max Fixed Contact 4 Poles 2 Normally Open 2 Normally Closed
(12) Item Master 572734, Diesel Fuel Oil
(13) Item Master 675214, Eaton Motor Starter Model AN16BN0AC

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On April 2, 2025, the inspectors presented the design basis assurance inspection (programs) inspection results to Gene Surber, Licensing Manager, and other members of the licensee staff.
  • On March 13, 2025, the inspectors presented the design basis assurance inspection (programs) inspection results to Edwin Dean III, Site Vice President, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Calculations

SR-6227

Seismic Analysis of Velan 3"-600 lb Pressure Seal Stop

Check Valve with Cowan Dynamics Air Cylinder Actuator

Revision 1

CR 11155593

Missing fasteners on 3B CRACS

2/26/25

CR 11160068

Failure to Monitor and Document Performance of SCT

Converter during Seismic Testing

03/12/2025

Corrective Action

Documents

Resulting from

Inspection

CR11160069

NRC Identified Issue #2 Associated with EMI/RFI

Evaluation

3/12/2025

Engineering

Changes

SNC 1730362ED

Fisher & Porter Power Supply Model 55GL1156 is

Obsolete

Revision 1

DR27672

Discrepancy Report for Pneumatic Actuator

05/20/2024

DRR-5579

Discrepancy Report for Auxiliary Switch

05/26/2022

QR-039010-1

Qualification and Dedication Report for Trane

Condensers and Cooling Coils

Revision 2

S1486-RP-01

Nuclear Environmental and Seismic Qualification Test

Report for the Siemens Type Q-10 Auxiliary Switches

Part Numbers 18364346501 and 18364346503

Revision 0

Engineering

Evaluations

SNC1927646ED

Starter, Eaton Cutler Hammer model A10BN0A is

Obsolete

Revision 1

CGD-351029814-

F6-24-1

Transformer

Revision 4

CGD-BF22F-

Farley-1

BF Relay, 2NO-2NC Contact Configurations 110/120 Vac

Coil Voltage Commercial Grade Dedication Package

Revision 4

CGD-

CSHA093D000-1

Scroll Compressor, 9 Ton

Revision 1

CGD-

CSHA140D0000-

Scroll Compressor, 14 Ton

Revision 1

CGD-

PR21001519-1

Auxiliary Switch

Revision 0

CGD-SCT

Converter-1

SCT Series Converter/Isolator Commercial Grade

Dedication Package

Revision 0

71111.21N.03

Miscellaneous

CGD-ZHSJ8ZN-1

Pneumatic Actuator

Revision 3

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

CGDS-002357

MOV Long Life Grease

5/15/2018

CJ2528-1

Dedication Plan for Siemens Molded Case Circuit

Breakers

Revision 5

GD-CNT02218-1

Low Pressure Cutout Pressure Switch

Revision 1

S1534-RP-02

STS Seismic Test Report - Item Master 589831

08/01/2001

SCM-CGDP-001

Number 2 Diesel Fuel Oil Commercial Grade Dedication

Plan

Revision 11

SCM-CGDP-189

Commercial Grade Dedication Plan for Damper

Components

Revision 1

SN9604-002

EMI Qualification Requirements

Revision 2

SNA 27679-0549

Receipt for MOV Long Life Grease

5/21/2018

SNA10328078

TRANSFORMER; CONTROL; 120/24 VAC; 30 VA

Revision 4

TE 1145300

Pre NRC CGD Inspection (Farley)

09/19/24

U-418349, QR-

039010-1

Qualification and Dedication Report for Trane

Condensers and Cooling Coils

Revision 1

U265839

Seismic Certification for Class 1E Equipment (Circuit

Breakers E6/ED6 Frame for Series 5600 MCCs)

03/14/1989

U418108

BF22 Relay Seismic and EQ Report

05/11/1994

NMP-Es-017-008

MOV Mechanical and Electrical Inspection

Revision

11.5

NMP-ES-065

CFR 50.69 Program

Revision 6

NMP-ES-201

Development of Technical/Quality Requirements

Revision 1

NMP-ES-205

Determining Acceptance Methods and Receipt Inspection

Requirements

Revision 1

NMP-ES-206

Accepting CGI for Use as Basic Components

Revision 1

Procedures

SCM-014

CFR 50.69 Alternate Treatment Procurement

Revision 4

FN072339

Purchase Order for Eaton Motor Starter

09/10/07

SNA10244408

SCT Converter/Isolator Purchase Order

06/02/2021

SNA10273614

Purchase Order for Auxiliary Switch

Revision 1

SNA10273614

Receipt for Auxiliary Switch

Revision 1

SNA10293227

Purchase Order for Scroll Compressor

Revision 1

SNA10293227

Receipt for Scroll Compressor

Revision 1

Shipping Records

SNA10331606

Purchase Order for Pneumatic Actuator

Revision 1

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

SNA10331606

Receipt for Pneumatic Actuator

Revision 1

SNA10334441

BF22 Relay Purchase Order

Revision 2

SNA10334441

BF22 Receipt Inspection

05/01/2024

SNA10341880

Purchase Order for Pressure Switch

Revision 2

SNA10341880

Receipt for Pressure Switch

Revision 2

SNA10345866

Receipt Inspection Diesel Fuel Oil

11/15/2024

SNA10345866

Purchase Order for Diesel Fuel Oil

09/18/2024

SNA47218-0214

Receipt Inspection for Siemens Molded Case Circuit

Breakers

11/07/2019

SNA47218-0214

Purchase Order for Siemens Molded Case Circuit

Breakers

Revision 2