IR 05000338/2023011

From kanterella
Jump to navigation Jump to search
– Quadrennial Focused Engineering Inspection Commercial Grade Dedication Report 05000338/2023011 and 05000339/2023011
ML23267A001
Person / Time
Site: North Anna  
(NPF-004, NPF-007)
Issue date: 09/26/2023
From: James Baptist
Division of Reactor Safety II
To: Carr E
Dominion Nuclear
References
IR 2023011
Download: ML23267A001 (1)


Text

SUBJECT:

NORTH ANNA POWER STATION, UNITS 1 & 2 - QUADRENNIAL FOCUSED ENGINEERING INSPECTION (FEI) COMMERCIAL GRADE DEDICATION REPORT 05000338/2023011 AND 05000339/2023011

Dear Eric S. Carr:

On August 17, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at North Anna Power Station, Units 1 & 2 and discussed the results of this inspection with Mr.

Jim Jenkins, Plant Manager, and other members of your staff. The results of this inspection are documented in the enclosed report.

One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement; and the NRC Resident Inspector at North Anna Power Station, Units 1 & 2.

If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; and the NRC Resident Inspector at North Anna Power Station, Units 1 & 2.

September 26, 2023

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, James B. Baptist, Chief Engineering Branch 1 Division of Reactor Safety Docket Nos. 05000338 and 05000339 License Nos. NPF-4 and NPF-7

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000338 and 05000339

License Numbers:

NPF-4 and NPF-7

Report Numbers:

05000338/2023011 and 05000339/2023011

Enterprise Identifier:

I-2023-011-0029

Licensee:

Dominion Nuclear Company

Facility:

North Anna Power Station, Units 1 & 2

Location:

Mineral, VA

Inspection Dates:

July 24, 2023, to August 11, 2023

Inspectors:

P. Braxton, Reactor Inspector

S. Campbell, Senior Reactor Systems Engineer

R. Fanner, Reactor Inspector

Approved By:

James B. Baptist, Chief

Engineering Branch 1, Division of Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a Quadrennial Focused Engineering Inspection (FEI) Commercial Grade Dedication at North Anna Power Station, Units 1 & 2, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

Corrective actions to verify material characteristics of item procured not consistent with procurement technical evaluation (PTE)

Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000338,05000339/2023011-01 Open/Closed

[P.3] -

Resolution 71111.21N.

The

NRC-Identified

a Green finding associated with a Non-cited violation of Title 10 CFR Part 50 Appendix B Criterion XVI, Corrective Action, for failure to verify material characteristics of an item procured were consistent with the procurement technical evaluation (PTE).

Specifically, the material properties were not verified consistent with the PTE methodology which directed verification of material characteristics to mitigate previous deficiencies in accordance with the instructions contained in MS-AA-MVL-101, Receipt Inspection, Rev 9 and the criteria added in PTE 10000012272, Rev. 11.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.21N.03 - Commercial Grade Dedication Commercial Grade Dedication (section 03.01)

(1) SCR, 42291078
(2) Transmitter, 42488999
(3) Belts, 37094110
(4) Valve, 42019703
(5) Bearings, 42091523
(6) Oil 42137857
(7) Oil, 37696340
(8) Circuit Breaker 480 V, 16455490
(9) Time delay relay, 03421330
(10) Control Relay 125 V DC, 06130460
(11) Printed Circuit Board, Amplifier,

INSPECTION RESULTS

Corrective actions to verify material characteristics of item procured not consistent with procurement technical evaluation (PTE)

Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000338,05000339/2023011-01 Open/Closed

[P.3] -

Resolution 71111.21N.0 The NRC-Identified a Green finding associated with a Non-cited violation of Title 10 CFR Part 50 Appendix B Criterion XVI, Corrective Action, for failure to verify material characteristics of an item procured were consistent with the PTE. Specifically, the material properties were not verified consistent with the PTE methodology which directed verification of material characteristics to mitigate previously deficiencies in accordance with the instructions contained in MS-AA-MVL-101, Receipt Inspection, Rev 9 and the criteria added in PTE 10000012272, Rev. 11.

Description:

The team identified an issue of concern related to the failure to adequately use the Fourier Transform Infrared Report (FTIR) test methodology (Method 1) to support the destructive testing criteria to verify the critical characteristics of Material ID, 37094110. FTIR is a common form of infrared spectroscopy. This methodology was based on review of corrective actions from condition report, SU-CR-000-CR1208021. This report identified a failure of similar belts at the Surry facility on or around September 18, 2022, where belts failed on multiple instances. In review of the condition report, one of the contributing causes for the failures were related to vendor quality issues. As a result, in support of Material ID 37094110, North Anna modified the acceptance criteria for the destructive testing of belts to utilize the FTIR methodology. Specifically, in PTE 10000012272, Rev. 11, the licensee specified the performance of FTIR testing to validate that belts were comprised of Ethylene Propylene Diene Terpolymer (EPDM) rubber, the inner cords were made of polyester, and the outer fabric sleeve was made of polyester fabric. Based on information reviewed, the licensee appeared to have missed this attribute and accepted the belts into stock. Based on the review of UD Lot Results With Parts Used WO Data - 6-13-2023, UD Data tab, two different belts associated with the PTE were received on April 17, 2023, for Material ID 37094110 and April 13, 2023, for Material ID 37094130.

The team concluded the procurements received specifying the FTIR methodology were also necessary since two commercial vendors were used to procure belts under this PTE based on Material ID 37094130. This material ID was not a part of the original inspection scope but revealed itself based on the use of PTE 10000012272, Rev. 11, which linked both material IDs. In addition, the linked material section of the PTE specified these material IDs and had an active status as of March 20,2023. The inspectors also reviewed SU-CR-000-CR1208021, written to address the Surry belt failures, and located the same material IDs referenced in PTE 10000012272, Rev. 11. This supported the basis for concluding the corrective actions were not adequate for the circumstances.

Corrective Actions: The licensee entered the issue into the corrective action program based on CR1235239 & CR1235267 and performed an operability determination.

Corrective Action References: CR-000-CR1208021 was initiated based on the Surry belt failures in 09/18/2022.

Performance Assessment:

Performance Deficiency: The licensee failed to adequately implement corrective actions to ensure the established requirements in MS-AA-MVL-101, Receipt Inspection, Rev 9 were implemented commensurate with circumstances for the performance and documentation of quality receipt inspection activities, to include Material Verification (MV) inspection activities.

Screening: The inspectors determined the performance deficiency was more than minor because if left uncorrected, it would have the potential to lead to a more significant safety concern. Specifically, the use of the FTIR methodology to verify material characteristics was listed in the PTE for 9 material IDs at North Anna and Surry. Absent NRCs intervention, the licenses failure to establish and perform appropriate acceptance testing for the specified material IDs used for replacements could lead to in-service component deterioration and resultant failures.

Significance: The inspectors assessed the significance of the finding using IMC 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power. the team determined the deficiency affected the design or qualification of a mitigating SSC, which at the time of the inspection, maintained its operability or PRA functionality. (Screened against IMC 0609, Appendix A, Exhibit 2, Step A1a, Green.) The applicable belts were installed on safety related HVAC systems which were linked to High-risk components, Emergency Switchgear Rooms.

Cross-Cutting Aspect: P.3 - Resolution: The team assessed the issue for cross-cutting aspects and determined one existed using the criteria in IMC 0310, Aspects Within the Cross-cutting Areas. Specifically, the team determined the Problem Identification and Resolution Area, Resolution attribute was most appropriate because the organization did not take effective corrective actions to address issues commensurate with their safety significance (PI.3).

Enforcement:

Violation: Title 10 CFR Part 50 Appendix B Criterion XVI, Corrective Action states, measures shall be established to assure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material, and equipment, and non-conformances are promptly identified and corrected.

CR-000-CR1208021 was initiated to document the V-belt failures which was adverse to quality. PI-AA-200, Corrective Action was used, in part, to establish measures to be taken to assure that conditions adverse to quality are promptly identified and corrected. PTE 10000012272, Rev. 11 was updated based on the PI-AA-200 procedure and specified the requirements for destructive testing based on corrective actions listed from CR-000-CR1208021.

Section 1, Purpose of MS-AA-MVL-101, Receipt Inspection, Rev 9 requires the specific instruction for ensuring material verification (MV) inspection activities were conducted.

Contrary to the above, the licensee did not accomplish the activity adequately to support correcting the condition documented above by not implementing the instructions contained in MS-AA-MVL-101, Receipt Inspection, Rev 9 and the criteria added in PTE 10000012272, Rev. 11 to support material verification using FTIR. Specifically, the material properties were not verified consistent with the PTE methodology which directed verification of material characteristics to mitigate previously deficiencies within the Dominion Energy fleet.

Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On August 17, 2023, the inspectors presented the Quadrennial Focused Engineering Inspection (FEI) Commercial Grade Dedication results to Mr. Jim Jenkins, Plant Manager, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.21N.03

Corrective Action

Documents

CR1208021

1-VS-AC-7 Belt Failure

9/18/2022

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1234419

Procedure MS-AA-PTE-401-1001 Inconsistency Found

07/31/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1234428

Self-Identified Discrepancy during NRC Inspection for

Commercial Grade Dedication

07/31/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1234518

NRC Identified: PTE 10000013530 missing Active

Functional Mode for Isolation Safety Function

8/01/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1234721

NRC Identified: Procedures MS-AA-MNI-401 and MS-AA-

PTE-401 Require Administrative Changes

08/03/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235026

NRC Identified: Purchase Order 4500382357 Receipt

Discrepancy

08/08/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235136

NRC Identified: Purchase Order 4500377130

08/09/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235145

NRC Observation: NRC Senior Resident Inspector

observed two access controlled doors not properly closed

08/09/2023

71111.21N.03

Corrective Action

Documents

CR1235204

NRC Identified: Shelf-life item in Warehouse has no

assigned shelf life

08/10/2023

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Resulting from

Inspection

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235233

NRC Identified Critical Characteristic not Verified for Valve

Seat Material

08/10/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235237

NRC Identified Inadequate FMEA per procedure

08/10/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235239

NRC Identified Material Verification not performed for SC

37094110

08/10/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235267

NRC Identified Material Verification for 37094130 and

37094120

08/10/2023

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

CR1235278

NRC Identified Shelf Life Not Identified for 42488999,

Rosemount transmitter

08/10/2023

71111.21N.03

Drawings

215-FB-034F

Flow/Valve Operating Numbers Diagram Compressed Dry

Air Bottle System North Anna Power Station Units 1 & 2,

Sheet 1 of 5

Rev. 22

71111.21N.03

Drawings

11715-FB-034F

Flow/Valve Operating Numbers Diagram Compressed Dry

Air Bottle System North Anna Power Station Units 1 & 2,

Sheet 2 of 5

Rev. 22

71111.21N.03

Drawings

11715-FB-034F

Flow/Valve Operating Numbers Diagram Compressed Dry

Air Bottle System North Anna Power Station Units 1 & 2,

Sheet 4 of 5

Rev. 22

71111.21N.03

Engineering

Changes

NA-21-00077

1-SI-TK-2 Boron Injection Tk-Header Flow, 01-SI-FT-

1943-IXMITR and Charging Pumps Disch Hdr to Bit Flow

Transmitter, 02-SI-FT-2943-IXMITR

3/27/2022

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.21N.03

Engineering

Evaluations

PTE

10000009369

version 2

Oil, turbine, zinc-free, DTE 732 (Material Identification No.

2137857)

05/23/2015

71111.21N.03

Engineering

Evaluations

PTE

10000036456

Procurement Technical Evaluation for Exxon Mobil

Teresstic 46 Turbine Oil (Material Identification No.

37696340)

7/21/2022

71111.21N.03

Engineering

Evaluations

10000037783

Rosemount Transmitter Model 3153N

8/11/2020

71111.21N.03

Engineering

Evaluations

10000054532

Molded Case Circuit Breakers, Thermal/Magnetc Fixed

Rev. 2

71111.21N.03

Engineering

Evaluations

10000069032

CGIE Inter Utility Rosemount PCB

Rev.0

71111.21N.03

Engineering

Evaluations

NA-SPEC-000-

NAS-0044

Specification for Recirculation Pumps

05/22/1972

71111.21N.03

Engineering

Evaluations

PTE

10000001048

Time Delay Relays

Rev.3

71111.21N.03

Engineering

Evaluations

PTE

10000009369,

Version 03

Oil, turbine, zinc-free, DTE 732 (Material Identification No.

2137857)

05/11/2023

71111.21N.03

Engineering

Evaluations

PTE

10000013530

Valve,CPV O-Seal System 1" MFR.: CPV Manufacturing

Inc.

11/07/2017

71111.21N.03

Engineering

Evaluations

PTE

10000018472,

Version 11

Procurement Technical Evaluation for Bearings, Ball &

Angular Contact, Single & Bearings, Ball & Angular

Contact, Single & Double Row

07/19/2016

71111.21N.03

Engineering

Evaluations

PTE

10000018472,

Version 14

Procurement Technical Evaluation for Bearings, Ball &

Angular Contact, Single & Bearings, Ball & Angular

Contact, Single & Double Row

11/17/2016

71111.21N.03

Engineering

Evaluations

PTE

10000073202,

Version 0

Oil, turbine, zinc-free, DTE 732 (Material Identification No.

2137857)

05/12/2023

71111.21N.03

Engineering

Evaluations

PTE 900395

Westinghouse Safeguards Panel Control Relays

Rev. 3

71111.21N.03

Miscellaneous

EPRI Report

1016272

Nuclear Maintenance Applications Center Turbine Oil

Compatibility

03/2008

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.21N.03

Miscellaneous

EPRI

Report1019593

Nuclear Maintenance Applications Center Radiation

Stability of Modern Turbine Oils

09/2009

71111.21N.03

Miscellaneous

PO 4500468575-

00001-

000000275263

Tyco Electronics Corp

2/04/2018

71111.21N.03

Miscellaneous

PO 4500486204-

00001-

000000277058

Purchase Order for Oil, turbine, zinc-free, DTE 732

(Material Identification No. 42137857)

10/25/2018

71111.21N.03

Miscellaneous

PO 4500494854-

00001-

000000275740

Tiger Controls Inc.

03/19/2019

71111.21N.03

Miscellaneous

PO 4500494854-

00001-

000000275983

Tiger Controls Inc

03/28/2019

71111.21N.03

Miscellaneous

Admiral Valve Trip Report

2/22/2017

71111.21N.03

Miscellaneous

10000021748

Rosemount 1154 B and D Series Amplifier and Calibration

Rev. 2

71111.21N.03

Miscellaneous

4500754346-

00001-

000000315232

Paragon Energy Solutions LLC

03/09/2022

71111.21N.03

Miscellaneous

59-A086-00001

Agastat 7000 Series Timing Relays, Models 7012, 7022,

& 7032

Rev.4

71111.21N.03

Miscellaneous

59-A086-00003

Agastat E7000 Series Timing Relay ( Double Pole Model)

Rev.3

71111.21N.03

Miscellaneous

59-R711-00006

Model 1153 Series Alphaline Pressure Transmitters for

Nuclear Service

Rev.5

71111.21N.03

Miscellaneous

59-R711-00007

Model 1153 Series D Alphaline Nuclear Pressure

Transmitters

Rev.8

71111.21N.03

Miscellaneous

D2013004

IEEE Qualification Report of Rosemount 3153N

Rev. B

71111.21N.03

Miscellaneous

DOM-QA-1

Nuclear Facility Quality Assurance Program Description

Rev. 35

71111.21N.03

Miscellaneous

DOM-QA-1

Nuclear Facility Quality Assurance Program Description

Rev. 19

71111.21N.03

Miscellaneous

DS-21-008

ExxonMobil Lubricants & Grease Commercial Grade

Survey Report

07/29/2021

71111.21N.03

Miscellaneous

ET-S-09-0112

Issuance of QDR-S-4.2 & N-4.2, Revision 13, OSRS

Pump Motors

Rev. 0

71111.21N.03

Miscellaneous

MMSR

Master Material Stock Request

10/15/2011

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

0000044656

71111.21N.03

Miscellaneous

MMSR 00071303

Master Material Stock Request

10/07/2020

71111.21N.03

Miscellaneous

Notification

200195900

Oil Fails Testing

2/20/2019

71111.21N.03

Miscellaneous

Notification

200229847

Missing Documentation for 55 gallons Teresstic 46, Batch

Nos. 70241883-01 and 702418238-01

09/08/2022

71111.21N.03

Miscellaneous

NQC 4733

Measuring and Test Equipment History Card

08/08/1990

71111.21N.03

Miscellaneous

PO 4500241653-

00001-

000000234469

Purchase Order for (Material Identification No. 42137857)

Oil, turbine, zinc-free, DTE 732

09/17/2015

71111.21N.03

Miscellaneous

PO 4500302377-

00003-

000000251492

Purchase Order for OM-Bearings, Ball & Angular Contact,

No.2 (Material Identification No. 42091523)

10/31/2016

71111.21N.03

Miscellaneous

PO 4500319699-

00001-

000000250412

Purchase Order for OM-Bearings, Ball & Angular Contact,

No.2 (Material Identification No. 42091523)

09/08/2016

71111.21N.03

Miscellaneous

PO 4500413591-

00002-

000000265163

Purchase Order for Valve, globe, 1", body material

aluminum (Material Identification No. 42019703)

11/17/2017

71111.21N.03

Miscellaneous

PO 4500486204-

00001-

000000275110

Purchase Order for Oil, turbine, zinc-free, DTE 732

(Material Identification No. 42137857)

10/25/2018

71111.21N.03

Miscellaneous

PO 4500506904-

00001-

000000276484

Purchase Order for Oil, turbine, zinc-free, DTE 732

(Material Identification No. 42137857)

2/08/2019

71111.21N.03

Miscellaneous

PO 4500506904-

00001-

000000277057

Purchase Order for Oil, turbine, zinc-free, DTE 732

(Material Identification No. 42137857)

2/08/2019

71111.21N.03

Miscellaneous

PO 4500603001-

00001-

000000297124

Westinghouse Repair & Replacement

09/10/2020

71111.21N.03

Miscellaneous

PO 4500754346-

00001-

000000315325

Paragon Energy Solution LLC

03/15/2022

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.21N.03

Miscellaneous

PO 4500786701-

00001-

000000321856

Purchase Order for Oil, lubricating, grade Teresstic 46, 55

gallons

09/08/2022

71111.21N.03

Miscellaneous

PO 4500786701-

00001-

000000321857

Purchase Order for Oil, lubricating, grade Teresstic 46, 55

gallons

09/08/2022

71111.21N.03

Miscellaneous

PO 4500788281-

00001-

000000320652

Purchase Order for Bearing, thrust (Material Identification

No. 42091523)

08/02/2022

71111.21N.03

Miscellaneous

PO 4500797806-

00001-

000000326373

Purchase Order for Oil, lubricating, grade Teresstic 46, 55

gallons

2/23/2023

71111.21N.03

Miscellaneous

PO 4500838815-

00001-

000000329385

Applied Industrial Technologies

94/17/2023

71111.21N.03

Miscellaneous

QDR-N-4.2/QDR-

S-4.2

Review Package of Electrical Equipment for North Anna

Power Station Units 1 & 2 and Surry Power Station Units

& 2

04/24/2014

71111.21N.03

Miscellaneous

QM1

Applied Technical Services, Inc. (ATS) Quality Manual

10/01/2018

71111.21N.03

Miscellaneous

Record Indexing

Data No.

4500302377

ProLog and Shipment Information for Material

Identification No. 42091523

10/31/2016

71111.21N.03

Miscellaneous

Record Indexing

Data No.

4500319699

ProLog and Shipment Information for Material

Identification No. 42091523

09/08/2016

71111.21N.03

Miscellaneous

SDBD-NAPS-QS

System Design Basis Document For Quench Spray

System

Rev. 24

71111.21N.03

Miscellaneous

TE Number

CGIVP03

EPRI CGI Joint Utility Task Group Commercial Grade

Item Evaluation For Valve Diaphragms And Seats

Rev. 1A

71111.21N.03

Procedures

MS-AA-PTE-

401-1001

Issuance and Control of Procurement TQAR Notes

Rev. 1

71111.21N.03

Procedures

0-OP-21.9A

Valve Checkoff - Control Room Bottled Air Pressurization

System

Rev. 11

71111.21N.03

Procedures

AD-AA-101

Preparation and Processing of Administrative Procedures

Rev. 16

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

and Guidance and Reference Documents

71111.21N.03

Procedures

CM-AA-400

CFR 50.59 and 10 CFR 72.48 - Changes, Tests, and

Experiments

Rev. 17

71111.21N.03

Procedures

CM-AA-ETE-101

Engineering Technical Evaluation (ETE)

Rev. 16

71111.21N.03

Procedures

CM-AA-ETE-101

Engineering Technical Evaluation (ETE)

Rev. 5

71111.21N.03

Procedures

DNES-AA-GN-

1005

Failure Modes and Effects Analysis (FMEA)

Rev. 3

71111.21N.03

Procedures

DNES-AA-MEL-

4001

The Safety Classification of Structures, Systems, And

Components

Rev. 1

71111.21N.03

Procedures

DNES-AA-MEL-

4001

The Safety Classification of Structures, Systems, And

Components

Rev. 2

71111.21N.03

Procedures

DNES-AA-MEL-

4001

Determining the Safety Classification of Structures,

Systems, and Components

Rev. 4

71111.21N.03

Procedures

DNES-VA-GN-

0038

Seismic Qualification of Equipment

Rev. 0

71111.21N.03

Procedures

Inspection Plan

00001122

VL-C333 STD PKG, DMG, CLN, QC, CGEI FOR 3/4"

VALVE TRIM PARTS

03/07/2002

71111.21N.03

Procedures

IP 00000811

Inspection Plan for OM-Bearings, Ball & Angular Contact

No. 2

2/06/2000

71111.21N.03

Procedures

IP 00000910

Inspection Plan for Oil, Mobil, Grade DTE 797 & 732

04/25/2001

71111.21N.03

Procedures

IP 00004470

Inspection Plan for Lubricant, Exxon, E2S, QG, QH

07/01/2022

71111.21N.03

Procedures

MA-AA-400

Measuring and Test Equipment

Revision 13

71111.21N.03

Procedures

MS-AA-10

Supply Chain Management Process

Rev. 1

71111.21N.03

Procedures

MS-AA-IEE-301

Item Equivalency Evaluation

Rev. 13

71111.21N.03

Procedures

MS-AA-MNI-401

Material Request and Material Requirements Planning

(MRP)

Rev. 16

71111.21N.03

Procedures

MS-AA-MVL-101

Quality Receipt Inspection

Rev. 9

71111.21N.03

Procedures

MS-AA-MVL-101

Quality Receipt Inspection

Rev. 4

71111.21N.03

Procedures

MS-AA-MVL-101

Quality Receipt Inspection

Rev. 9

71111.21N.03

Procedures

MS-AA-PRO-401

Procurement Control

Rev. 12

71111.21N.03

Procedures

MS-AA-PRO-402

Purchase Orders

Rev. 8

71111.21N.03

Procedures

MS-AA-PTE-401

Procurement Technical Evaluation Determination

Rev. 16

71111.21N.03

Procedures

MS-AA-PTE-401

Procurement Technical Evaluation Determination

Rev. 21

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.21N.03

Procedures

MS-AA-PTE-401

Procurement Technical Evaluation Determination

Rev. 8

71111.21N.03

Procedures

MS-AA-PTE-401

Procurement Technical Evaluation Determination

Rev. 10

71111.21N.03

Procedures

MS-AA-PTE-401

Procurement Technical Evaluation Determination

Rev. 17

71111.21N.03

Procedures

MS-AA-PTE-401-

1001

Commercial Grade Dedication

Rev. 10

71111.21N.03

Procedures

MS-AA-PTE-401-

1002

Sampling Methodology for Material Acceptance

Rev. 1

71111.21N.03

Procedures

MS-AA-PTE-401-

1004

Commercial Grade Dedication

Rev. 10

71111.21N.03

Procedures

MS-AA-PTE-401-

1004

Commercial Grade Dedication

Rev. 3

71111.21N.03

Procedures

MS-AA-PTE-401-

1004

Commercial Grade Dedication

Rev. 6

71111.21N.03

Procedures

MS-AA-SCE-301

Subcomponent Classification Evaluation

Rev. 3

71111.21N.03

Procedures

MS-AA-SLD-701

Shelf Life Evaluation and Control

Rev. 5

71111.21N.03

Procedures

MS-AA-SLD-701

Shelf Life Evaluation and Control

Rev. 2

71111.21N.03

Procedures

MS-AA-SLD-701

Shelf Life Evaluation and Control

Rev. 3

71111.21N.03

Procedures

MS-AA-TRN-202

Procurement Engineering Services Qualification and

Certification Program

Rev. 6

71111.21N.03

Procedures

MS-AA-VEN-101

Vendor Surveillance

Rev. 3

71111.21N.03

Procedures

MS-AA-WHS-131

In-Storage Maintenance of Items

Rev. 8

71111.21N.03

Procedures

MS-AA-WHS-132

Control of Shelf Life Material

Rev. 1

71111.21N.03

Procedures

MS-AA-WHS-133

In-Storage Maintenance of Items

Rev. 3

71111.21N.03

Procedures

MSS SP-61-2013

Pressure Testing of Valves

71111.21N.03

Procedures

NO-AA-VEN-210

Safety-Related and Commercial Grade Vendors Lists

Rev. 1

71111.21N.03

Procedures

PI-AA-200

Corrective Action

Rev. 41

71111.21N.03

Procedures

VPAP-0704

Shelf Life Evaluation and Control

Rev.6

71111.21N.03

Procedures

VPAP-0812

Station Lubrication Program

Rev. 18

71111.21N.03

Procedures

VPAP-0812

Station Lubrication Program

Rev. 19

71111.21N.03

Procedures

VPAP-704

Shelf Life Evaluation and Control

Rev.11

71111.21N.03

Procedures

WM-AA-100

Work Management

Rev. 25

71111.21N.03

Radiation

Surveys

MS-AA-WHR-401

Receiving

Rev. 8

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.21N.03

Self-

Assessments

PIR1218044

Assessment of Commercial Grade Dedication Process in

Preparation for 2023 NRC CGD Inspection

7/10/2023

71111.21N.03

Work Orders

WO- 203382334,

WO- 203382347,

WO- 59103055866,

WO- 203287396,

WO- 203286653,

WO- 599203384230,

WO- 203390799,

WO- 203297317,

WO- 203298068,

WO- 203365582,

WO- 59102959027,

WO- 203322661,