Text
U. S.
NUCLEAR REGULATORY COMMISSION
REGION III
Repor t Nos.
50-315/87031(DRP);
50-316/87031(DRP)
Docket Nos.
50-315; 50-316 Licensee:
Indiana Michigan Power Company 1 Riverside Plaza Columbus, OH 43216 License Nos.
Donald C.
Cook Nuclear Power Plant, Units 1 and
Inspection At:
Donald C.
Cook Site, Bridgman, MI Inspection Conducted:
November 11 through December 14, 1987 Inspectors:
B. L. Jorgensen J.
K. Heller P.
R.
Rescheske d
R.
C.
Kazmar Approved By:
B. L. Burge
, Chief Reactor Projects Section 2A Ins ection Summar D te Ins ection on November 11 throu h December
1987 Re ort Nos.
50-315/87031 DRP
~II>>
R R I, dd I
I Id dR I
III inspectors of:
actions on previously identified items; operational safety verification; radiological controls; maintenance; surveillance; fire protection; security; reportable events; Bulletins, Notices and Generic Letters.
Results:
No violations or deviations were identified in any areas inspected.
QBQ
~DOC~ QgQQQS>
Q~aQQQ~~ 8
'
PDR PDR
DETAILS 1.
Persons Contacted
- W. Smith, Jr., Plant Manager A. Blind, Assistant Plant Manager Administration
- J. Rutkowski, Assistant Plant Manager Production
"L. Gibson, Assistant Plant Manager - Technical Support
- B. Svensson, Licensing Activity Coordinator
"K. Baker, Operations Superintendent
"J.
Sampson, Safety and Assessment Supervisor E. Morse, quality Control Superintendent
'T. Bei lman, I&C/Planning Superintendent
- J. Droste, Maintenance Superintendent
- T. Postlewait, Technical Superintendent
- Engineering L. Matthias, Administrative Superintendent M. Horvath, guality Assurance Supervisor
- W. Hodge, Security Manager
- J. Kauffman, Construction Manager
- R. Huerter, gA Supervisor Auditor
"C. Ross, Computer Science Superintendent The inspector also contacted a number of other licensee and contract employees and informally interviewed operations,.
maintenance, and technical personnel.
- Denotes some of the personnel attending Management Interview on Dec'ember 15, 1987.
2.
Actions on Previousl Identified Items a.
(Closed)
Open 'Item (315/85034-02; 316/85034-02):
determine acceptability of resetting bistable trips using Surveillance Procedures (STPs)
.025 and
.026 instead of STP.080.
The following documents were utilized during this review:
(1)
1-THP 4030 STP.025,
"Intermediate Range Nuclear Instrumentation Protection Set I (N-35) Surveillance Test," Revision 5.
(2)
1-THP 4030 STP.026,
"Intermediate Range Nuclear Instrumentation Protection Set II (N-36) Surveillance Test," Revision 6.
(3)
1-THP 4030 STP.080,
"(SU-1) Instrumentation Checks Prior to Startup," Revision 7..
From review of the applicable sections of the above procedures, it was apparent that the operability tests for the N-35 and N-36 detector bistable trips.(high level rod stop and high level trip)
are comparable tests.
However, the '"Precautions" in STP.080 state that a retest will be performed using the appropriate section of STP.080.
In this specific example, the test results obtained from STPs
.025 and
.026 would have been identical to those from STP.080
and therefore technically valid. It does appear that STP.080 should have been used for consistent documentation purposes.
This open item is considered closed.
b.
(Closed)
Open Items (315/85034-03; 316/85034-03):
review of licensee actions to improve control of the Instrumentation and Control (IKC)
Department reference documents.
The subject reference documents are used for satisfying safety-related work; e.g.,
copies of some completed surveillance tests are used to obtain setpoint values for future testing.
Licensee actions responsive to the inspector concern included placing permanent signs on the file drawers instructing personnel that the documents are for reference only and are not to be marked on.
This open item is considered closed.
No violations, deviations, unresolved or open items were identified.
3.
0 erational Safet Verification Routine facility operating activities were observed as conducted in the plant and from the main control rooms.
Plant startup, steady power operation, plant shutdown, and system( s) lineup and operation were observed as applicable.
The performance of licensed Reactor Operators and Senior Reactor Operators, of Shift Technical Advisors, and of auxiliary equipment oper'ators was observed and evaluated i.ncludin'g procedure use and adherence, records and logs, communications, shift/duty turnover, and the degree of professionalistn of control room activities.
Evaluation, corrective action, and response for off normal conditions
'r events, if any, were examined.
This included compliance to any reporting requirements.
Observations of the control room monitors, indicators, and recorders were made to verify the operability of emergency systems, radiation monitoring systems and nuclear reactor protection systems, as applicable.
Reviews of surveillance, equipment condition, and tagout logs were conducted.
Proper return to service of selected components was verified.
A number of operating off-normal procedures were reviewed as follows:
(1)
1-OHP 4024. 113 "Annunciator No.
13 Response Steam Generator
and 2," Revision 2, dated 4/29/82 through Change Sheet 10.
(2)
1-OHP 4024. 114 "Annunciator No.
14 Response Steam Generator
and 4," Revision 2, dated 4/20/82 through Change Sheet 2.
(3)
2-OHP 4024.213
"Annunciator No.
13 Response Steam Generator
and 2."
The review identified some minor inconsistencies among the procedures.
These inconsistencies, which involved only support
information and references, not response instructions, were identified to the Operations Department procedure group for evaluation; they had already been noted and are being addressed in pending Revisions due within the month.
Particular notice was taken on routine tours of areas containing substantial steam piping, valves, instruments and connections.
A significant reduction in the number and nature of minor steam leaks is evident in these areas.
This is particularly true of the Unit
safety/relief valve gallery and main steam isolation valve area.
Licensee maintenance activities during the Unit 1 refueling and Unit 2 testing outages were apparently quite effective in correcting several old leaks.
Additional efforts have continued since the outage to repair leaks (see Paragraph S.b involving a recent Unit 2 example)
as they develop.
During one Unit 1. Control Room tour with an Assistant Plant Manager (December 2,
1987) the inspector toured the rear control panel areas.
Framing and cable over the top rear of the feedwater panel area was observed to have an accumulation of dusty "felt" to about one-half inch in depth.
Normally, the licensee vacuums and cleans back panel areas during outages, when the potential for adverse consequences (from static sparks or bumping/vibrating instruments and connections)
is minimized.
The subject area, however, appeared not to have been attended to for some considerabl.e time.
This area, and the Uni.t 2 panels which also had some accumulation, were cleaned up prior to the end of the inspection.
Technical Specification 3.3.1.1 for both Units establishes, through reference to Table 3.3-1 and its associated ACTION 1, that a reactor trip breaker (RTB) ".
.
.may be bypassed for up to two hours for surveillance testing.
.
.."
On November 18, 1987, RTB surveillance testing experienced problems (see Paragraph 6.c)
and the RTB remained bypassed two hours and five minutes.
The operating crew on duty at the time decided the two hour condition should be considered a time limit, which was violated.
Accordingly, they logged a determination that the plant entered Technical Specification 3.0.3 (Limiting Condition for Operation not met) at the two-hour mark:
This seemed potentially nonconservative since 3.0.3 provides one hour to commence shutdown and six more to achieve HOT 'STANDBY (seven hours total).
The Table 3.3-1 ACTION 1 itself, however, contains a limit of six hours to HOT STANDBY.
This matter was discussed with the licensee and with the NRC Office of Nuclear Reactor Regulation (NRR).
The licensee was advised the two hours "...for surveillance...."
is a.grace period, not a time limit, and that inability to complete surveillance within the grace period is meant to start the six-hour shutdown "clock", not start the seven-hour clock of Specification 3.0.3.
The licensee accepted the interpretation and pointed out they hadir by procedure, been running the six-hour clock from the time the surveillance testing was begun, which greceded placing the RTB in "bypass".
This was a
conservative approach and assured no time limits for shutdown would be exceede e.
During a tour of the screenhouse,
%he inspector found clam shells in the trash bins.
Samples were provided to the onsite environmental group who confirmed that the shells were not the type that can cause biofouling of the condenser or heat exchangers.
No violations, deviations, unresolved or open items were identified.
4.
Radiolo ical Controls During routine tours of radiologically controlled plant facilities or areas, the inspector observed occupational radiation safety practices by the radiation protection staff and other workers.
Effluent releases were routinely checked, including examination of on-line recorder traces and proper operation of automatic monitoring equipment.
Independent surveys were performed in various radiologically controlled areas.
a.
During routine log reviews, the inspector noted the licensee was frequently opening the auxiliary building roof vent, presumably to venti late heat/haze accumulated in a large scale welding project (see Paragraph 5.d) in support of the upcoming Unit 2 Steam Generator Repair Project.
The inspector was concerned that potential airborne radiation releases could occur via the vehts which would be neither quantifiable nor., in case of some problem, readily isolable.
The Radiation Protection (R-P) organi,zation was contacted regarding this concern.
They reported identification of the same concern on their own part a couple of weeks earlier.
Initially, R-P refused to sanction routine opening of the vents.
Subsequentl'y, adequate administrative controls were developed involving the stationing of a dedicated individual on the roof, with a two-way radio, to remain continuously available to close the vents on notification from either control room.
This addressed the concern about isolability in case of an adverse event.
Regarding unquantifiable leakage, the airflow through the vents is inward, not outward, due to continuous operation of building fans to maintain a
slight negative building pressure.
Loss of the fans is one adverse event for which the roof vents would immediately be closed.
The inspector had no further questions on this matter.
b.
Licensee technician on-the-job training/qualification activities were observed and discussions were held with the instructing technicians and two qualifying technicians.
The specific qualification activity involved demonstrating competence in performance of procedure
- 12 THP 6020.PAS.011,
"Post Accident Sampling for Hydrogen and Dilute Liquid and Total Gas Grab Samples,"
Revision 2, dated 10/19/82 through Change Sheet 12.
The inspector also performed inspections of the licensee's hot and cold laboratories, observation of selected analytical practices, discussions with technicians, and brief general examination of equipment and procedure c
~
On December 2,
1987, the inspector performed independent surveys on a radwaste shipment prior to its departure enroute to a licensed burial facility.
The shipment consisted of a single Type B cask containing spent resins and approximately 360 Ci of activity.
The inspector's survey results were quite consistent with those obtained and documented by the licensee, and did not closely approach regulatory limits.
Inspection of the cask showed it to be properly sealed and secure.
d.
On December 10, the inspector attended a meeting in the NRC Region III offices among 'licensee and NRC Region III representatives.
The purpose of the meeting was to discuss licensee plans in the radiation protection organization relating to staffing and management, and relating to other potential performance enhancement possibilities.
No violations, deviations, unresolved or open items were identified.
5.
Maintenance Maintenance activities in the plant were routinely inspected, including both corrective maintenance (repairs)
and preventive maintenance.
Mechanical, electrical, and instrument and control group maintenance activities were included as available.
The focus of the inspection was to assure the maintenance activities revi'ewed were conducted in accordance w'ith approved procedures, regulatory guides and -industry codes or standards and in conformance'ith
'echnical Specifications'.
The following items were considered, during this review: the Limiting Conditions for Oper'ation were met while components or systems were removed from service; approvals were obtained prior to initiating the work; activities were accomplished using approved procedures; and post maintenance testing was performed as applicable.
The following activities were inspected:
a.
The inspector reviewed procedure MHI-5030 "Preventive Maintenance and Surveillance/Maintenance/Replacement Program,"
Revision 9, dated 10/23/86.
The review was confined to a brief general overview, plus a focus on Attachment 30, "Plant Winterization and De-winterization."
Revision 9 contains relatively detailed instructions concerning steps to "winterize" the plant usually before October 31 each year but no data sheets for recording completion of the activities.
Licensee practice has been to note completion of various items by marking up a copy of the procedure itself.
As part of a procedure upgrade, Revision 10, which is nearing completion, will contain preprinted
.
data sheets (matching up with instruction steps) for recording when and by whom the steps were performed.
The 1987 winterization was carried out with documentation on draft data sheets created especially for that purpose from the proposed Revision.
The inspector reviewed these documents for their completeness and found no problem The instructions and documentation were specifically noted to cover both inspection and/or test of equipment to verify proper operation and installation of specified "extras," e.g.,
covers over openings, etc.
Job Order JO 027269 Repair of valve 2-MSM-242 (Unit 2, Steam Generator No. 4, MSIV pilot valve) using procedure
"12 MHP 5021.001.075,
"Repair Procedure for Fisher Controls Angle Valves,"
Revision 0, dated 3/6/86.
The valve was experiencing a steam leak through the disc/seat interface.
The repair involved replacement of internal parts, with the inspector witnessing old parts inspection, new parts installation, independent pre-closure cleanliness inspection, reassembly and closure torquing.
The cleanliness inspection was performed, per procedure, by another maintenance mechanic who was not part of the work crew doing the repair.
A plant guality Control group inspector was also present performing an optional surveillance inspection of the subject repair and followup restoration testing by Instrument and Control personnel (see Paragraph 6.b).
Job Order JO 717900 Fabrication of a work platform for installation atop the SFP bridge crane frame to support/provide access for RFC to strengthen the auxiliary building crane support structure.
Job Order JO 717955.
Melding/strengthening auxiliary building crane rails per design change RFC-DC-2692.
The. inspector observed gC personnel performing nondestructive (MT) examinations on several welds, then briefly reviewed followup documentation.
Though no relevant indications were identified in any of the subject welds, which were among the first examined, subsequent examinations showed that flaws were present or developing in existing welds and in base metal.
The project is subsidiary to the planned replacement of the Unit 2 steam generators and is necessary because the existing crane support structure was not designed for potential loads (including seismic) to which it may be exposed in handling the removed and repl.acement components.
The strengthening includes fixing sizeable plate, with large welds, to the existing structure.
The stresses involved in the application of a large number of heavy welds were considered responsible for development of the observed flaws.
Both the resident inspector and Region III specialists are closely following this project, including problem identification and resolution.
Job Order JO 021122 Rebuild/retest of snubber.
The system engineer during a tour of the containment found a snubber that was leaking oil.
The snubber was replaced with an acceptable snubber from stock and failed a subsequent functional test.
The inspector verified that the Technical Specification action statements were met and that the licensee considered this snubber a failure for purposes of scheduling the next visual inspection frequenc Job Order JO 000301 Implement design change RFC-OC-2859 to remove and replace the steam coil in the South boric acid evaporator.
Due to cumulative tube leaks over the years in the 304 SS (stainless steel) tubing, sufficient tubes had been plugged to significantly reduce evaporator capacity.
The design change primarily involved replacing the original 304 SS bundle with an Incaloy 825 bundle assembly.
Other minor changes were included.
Tube bundle removal was observed to include compliance to requirements of associated Radiation Work Permit RWP 0626, such as:
direct dedicated R-P Technician coverage; proper anti-C clothing; and full-face respiratory protection.
The document package was subsequently reviewed and contained appropriate instructions, procedures and drawings as required by various administrative control processes.
At the time of the document review, a conflict between plant and vendor (Westinghouse)
information for re-torquing specifications had been identified.
The licensee's procedure
MHP 5021.001.009 s'pecified 175 ft.-l.bs., while the vendor manual called for 50 ft.-lbs.
A subsequent.
licensee engineering evaluation determined desir'ed torque values, which were relayed to the contractor for implementation and to contractor guality Control for verification.
The following Job Order packages were reviewed:
JO 86985X1 Furmanite valve 1-DCR-330 on 10/1/84 JO 76607 Furmanite valve 1-DCR-330 on 10/10/84 JO 91403
Rebuild valve 1-DCR-330 on'12/12/84 JO 91498Xl Furmanite valve 1-DCR-310 on 12/22/84 JO 91523Xl Rebuild valve 1-DCR-320 on 12/26/84 JO 90790 Furmanite valve 1-DCR-310 on 12/28/84 and rebuild on 6/6/85 JO 16048 JO 86785 Furmanite valve 1-DCR-310 on 3/9/85 Rebuild valve 1-OCR-330 on 6/21/85 JO 99430 JO 2633 JO 2707 JO 9024 JO 711256 JO 711782 JO 713081 JO 1522 Tighten valve 1-DCR-340 packing on 4/7/86 Tighten packing for valve 1-DCR-310 on 7/8/86 Rebuild valve 1-DCR-310 on 7/8/86 Furmanite valve 1-DCR-310 on 9/30/86 Changed valve 1-DCR-340 packing on 12/15/86 Furmanite valve 1-DCR-310 on 2/19/87 Overhaul valve 1-DCR-320 on 2/22/87 Rebuild valve 1-DCR-310 on 5/30/87 Review of the above work packages raised two questions.
First, a
work history review on the subject valves (steam generator blowdown isolation valves)
shows they had required repetitive packing replacement or adjustments, especially 1-DCR-310, which had been worked five times in 'three years.
The licensee provided a
summary of his ongoing Valve Maintenance Tracking 'Program - Air Operated Valves dated April 1987.
Identification of valves with an
inordinate maintenance history is summarized, including valves requiring five or more packing/repacking jobs since 1980.
There are 23 such valves, including 1-DCR-310, identified on an attached Table and recommended for consideration as candidates for the licensee's
"Live Loaded Packing Program."
The inspector was satisfied the licensee has paid attention to identifying and resolving repetitive valve problems in this area.
The second question involved documentation and qualification of repair parts used for Job Order JO 713081 and JO 001522.
Each Job Order contained a
"memo of telephone conversation" allowing use of replacement parts that had been purchased without requiring certification of material or NDE.
The inspector questioned the basis for this.
The licensee review was documented in a memo dated'ecember=
14, 1987 on the subject of "S" parts on "N" valves.
The memo states that the replacement parts were flexible gaskets, and Code Case N-62-4 is stated to exclude gaskets from any certification of material or NDE requirements.
The acceptability of "S" parts in
"N" valves is an open item that will be reviewed in a future inspection (Open Item 315/87031-01; 316/87031-01).
One open item, no violations, deviations, or unresolved items were identified.
Surveillance The inspector reviewed Technical Specifications required surveillance testing. as described below and verified that testing was performed
.in accordance with adequate procedures, that test instrumentation was calibrated, that Limiting Con'ditions for Operation were met, that removal and restoration of the affected components were properly accomplished, that test results conformed with Technical Specifications and procedure requirements and were reviewed by personnel other than the individual directing the test, and that deficiencies identified during the testing were properly reviewed and resolved by appropriate management personnel.
The following activities were inspected:
a.
" 12-THP 4030 STP.307
"Moderator Temperature Coefficient Determination," Revision 12, dated 8/27/87.
Performed for Unit 2 on 12/1/87 at about 340 ppm boron (80% power)
to meet Technical Specifications for testing at 300 ppm equivalent for full power.
b.
12-THP 6030 IMP.030
"Air Operated Valves Checkout Procedure."
Instrument and Control personnel performed this test as part of restoration of valve 2-MSM-242 to "operable" following maintenance ( see Paragraph 5.b).
Initiation and tracking of this support activity were pursuant to Job Order JO SP.02400 *"1-THP 4030 STP.411
"Reactor Trip SSPS Logic and Reactor Trip Breaker Train "B" Surveillance Test (Monthly)," Revision 1, dated 10/3/85 through Change Sheet 5 dated 10/8/87.
The inspector observed a successful repeat performance of this test in the afternoon of November 18, 1987 after problems were encountered in performance of the test in the morning.
Unit 1 Technical Specifications require the reactor trip breakers be operable except they may be bypassed for up to two hours for this required monthly testing.
During the morning test, a technician erred in positioning test switches in the control logic cabinet early in the test sequence.
The error was not caught by an independent verifier.
As a consequence, test results did not meet procedure acceptance criteria and it was necessary to stop the test (with the "B" trip breaker still bypassed)
and investigate.
The error was found and corrected, and the test was completed with acceptable results.
The total elapsed time with the
"B" breaker bypassed, however, was five minutes over the two-hours given in Technical Specifications. 'he test was repeated in the afternoon to assure the error and associated troubleshooting had not resulted in some unknown/unsatisfactory condition in circuits checked before the error was made.
A "clean" test with fully successful results was thus left for the record.
As discussed i.n Paragraph 3.d above, the inspector subsequently questioned the licensee's treatment of the two-hours (provided in Technical Specifications for testing)
as a time'imit.
The Control Room Logs reflected an interpretation that Technical Specification 3.0.3 (Limiting Condition'or Operation not met)
was entered upon inability to unbypass the "B" breaker within two hours.
Concurrently, the licensee had administratively implemented an associated six-hour ACTION statement to achieve hot shutdown because the "B" channel was considered inoperable.
On consultation with the Office of Nuclear Reactor Regulation, the inspector learned the two hours was developed as a grace period, not a time limit.
Thus, unless other information already exists to show the "B" channel is inoperable, the six-hour ACTION statement begins when the grace period ends.
Reference to Specification 3.0.3 is inappropriate.
This information was given to the licensee.
- 12-MHP 4030 STP.002
"Main Steam Safety Valve Set Point Verification."
STP.002 implements the testing requirements of Technical Specification 4.7.1.1.
Unit 1 Specification requires that code safety valves shall be demonstrated operable, with lift setting and orifice sizes as shown in Table 4.7-1 in accordance with Section XI.
The Unit 2 Specification only requires verification of lift settings.
STP.002 verifies the lift setting, however, it is silent on the orifice size.
During discussion with the licensee it was determined that the site guality Assurance Department had previously asked (on July 24, 1986) whether the orifice size must be verified.
At that time the documented response was "no".
The justification is based on the fact that the orifice is an integral part of the nozzle and
cannot be changed unless the nozzle is removed; verification of orifice size would require valve removal and disassembly; and, orifice size verification is not required by Section XI.
In addition, the discrepancy between Units was previously identified and included in a Technical Specification Change Request (AEP:NRC:0433L dated July 3, 1986) to convert the Unit
specification to be consistent with Unit 2.
On November 17, 1987 the inspector contacted the NRR Licensing Project Manager who stated the subject change request was not on the licensee-provided list of active Technical Specification Change Requests.
The need to verify orifice size during each surveillance was discussed and it appears the licensee is meeting the intent of the Technical Specifications to test to Section XI.
The status of the Technical Specification change request was discussed with the licensee who stated that a number of requests pertaining to Section XI had been withdrawn and consolidated, at NRR request, to assure that all desired requests were made.
The consolidated requests should be submitted in the near'uture.
The inspector asked the licensee to verify that the valves were originally procured with 16 square inch orifice sizes as stated in the Technical Specification for Unit 1.
The licensee provided an August 24, 1977 letter from the valve vendor (Dresser Industries)
with associated attachments, which.the inspector reviewed and found satis'factory.
The inspector then asked for information concerning'he nature of valve "reconditioning" performed.on eight of the 20 valves in late 1983 to assure this activity had not affected orifice size.
The licensee provided documentation from the contractor (Mark Controls Corporation)
who had performed the reconditioning.
A review of a sample of the documentation package showed no work was done which would affect the 4.515 inch bore diameter orifice.
- "12-THP 4030 STP.232
"Post Accident Sample Sink (PASS)
Panel Ventilation Test."
Equipment problems prevented a successful completion of the test on November 17, however the portion of the test observed demonstrated that the performance technicians had a
working knowledge of the surveillance procedure.
When equipment problems were identified the technicians initiated Job Orders (corrective maintenance documents)
and consulted with cognizant engineers assuring that the equipment problems would not influence the test results.
The surveillance is unique because potentially internally contaminated equipment, located in the Unit 1 Reactor Cable Tunnel (not normally a radiologically contaminated area)
required disassembly for inspection.
The inspector confirmed that the test had been reviewed with Radiation Protection, the technicians were on the assigned Radiation Work Permit (RWP), everyone was wearing personnel monitoring equipment as required by the RWP, and that good radiological work practices were used.
"*1-OHP 4030 STP.007E
"East Containment Spray System Operability Test," Revision 3, dated 5/14/87.
""1-THP 6030 IMP.131
"Power Range Nuclear Instrumentation Calibration N41, N42, N43, N44," Revision 12, dated 6/5/86 through Change Sheet 4 dated 8/21/86.
The inspector observed parts of the calibration of excore power range nuclear instrument N41 only, which the licensee was performing to adjust excore instruments following a routine incore flux mapping test the preceding week.
h.
PMI-6040 "Performance/Engineering Test Procedures,"
Revision 4, dated 11/27/86.
This procedure contains the master administrative controls for test procedures of the Performance Section and the Nuclear Section within the Technical/Engineering Department.
It is pursuant to this procedure that most non-Technical Specification and other test (e.g.,
ANSI 510-1975 for air cleaning systems)
procedures are developed and scheduled.
Numerous cross-references to associated PMI procedures are made.
The inspector had only a single question concerning this PMI, involving a provision for when ".
.
.a limiting condition must be exceeded.
.
.." that implied the Plant Nuclear Safety Review Committee.(PNSRC) could grant waivers to Technical Specifications.
'Discussions with licensee management representatives indicated this
'as not the intent of the subject waiver provision; rather, it was to fl'ag cases wherein the intent of 6040-procedures (to have no Technical Specification im~pact needed to be changed.
No cases were known involvino "waiver" of Technical Specification limiting conditions.
The licensee implemented a revision to procedure PMI-6040 to clarify the intent.
No violations, deviations, unresolved or open items were identified.
7.
Fire Protection Fire protection program activities, including fire prevention and other activities associated with maintaining capability for early detection and suppression of postulated fires, were examined.
Plant cleanliness, with a focus on control of combustibles and on maintaining continuous ready access to fire fighting equipment and materials, was included in the items evaluated.
'a ~
On November 24, 1987 and again on December 11, 1987 the licensee reported that preplanned maintenance activities to install new valves in the outside fire suppression water ring header, necessitated isolation of a portion of the header.
Provision of backup suppression capability and followup written notification were both accomplished in accordance with fire protection Technical Specifications.
r b.
The inspector provided information to the licensee concerning damage to a buried fire protection ring header at another nuclear plant, apparently caused by movement of very heavy loads on the road over the buried header.
The steam generator repair project at Unit 2 in 1988 will involve moving very heavy loads over the D.
C.
Cook buried ring header.
No violations, deviations, unresolved or open items were identified.
8.
~Securit Routine facility security measures, including control of access for vehicles, packages and personnel were observed.
Performance of dedicated physical security equipment was verified during inspections in various plant areas.
The activities of the professional security force in maintaining facility security protection were occasionally examined or reviewed, and interviews were occasionally conducted with security force members.
No violations, deviations, unresolved or open items were identified.
9.
Re ortable Events The inspector reviewed the following Licensee Event Reports (LERs) by means of direct observation, discussions with licensee personnel, and review of records.
The review addressed compli-ance to reporting
'requirements and, as applicable, that immediate corrective action and appropriate action to prevent recurrence had been accomplished..
a.
(Closed)
LER 316/87011, Revision 0:
ESF.Actuation caused by personnel error - blocks not reinstated when returning solid sate protection system to service.
A Unit 2 Train A safety injection actuation occurred October 2, 1987, while the Unit was in MODE 5 (cold shutdown).
Available equipment responded properly to the actuation signal.
The cause of the actuation was an error made by Instrument and Control (I&C) personnel, who were performing testing and repairs involving inputs to the subject channel.
When returning circuits to service after troubleshooting and replacement of a failed undervoltage output board, the safety injection "blocks" (required in MODE 5) were not all reinstated due to a switch sequencing error.
The root cause was determined to be failure to properly evaluate a needed change in the scope of the activity being conducted (i.e., the need to perform repairs in the middle of a test in order to complete the test)
such that available procedures/
instructions were not fully utilized.
All I&C personnel were issued a reminder regarding the requirement to re-evaluate, upon any determination of a change in. work scope, to complete a task.
b.
(Closed)
LER 315/87012, Revision 0 and Revision 1:
Type B and C
containment leak rate test failure due to a ripped diaphragm and undetermined cause(s).
Generic implications associated with repetitive findings (this event being the tenth) involving Type C
local leak test failures are discussed in evaluation of an
associated Unresolved Item (315/85025-06)
in I.E. Inspection Report 315/87024(DRP);
316/87024(DRP).
The current inspection examined specific actions associated with this specific LER, which identified two valves of concern.
These valves (SF-159 and SF-160, in series)
are manual diaphragm-type valves from the reactor coolant drain tank to,the refueling water purification pumps.
Both valves were repaired (though only SF-159 contained a ripped diaphragm)
by replacement of their diaphragms.
Post-maintenance testing showed very low leak rates, well within limits.
The licensee is implementing twice per cycle (vs. once) testing of diaphragm-type isolation valves to ascertain appropriate performance characteristics and preventive repair/replacement information.
Neither valve had previously been involved in a leak test failure.
No violations, deviations, unresolved or open items were identified.
10.
NRC Com liance Bulletins and Generic Letters The inspector reviewed the NRC communications listed below and verified that:
the licensee has received the correspondence; the correspondence was reviewed by appropriate management representatives; a written response was submitted if required; and, plant-specific actions were taken as described in the licensee's response.
'a ~
(Open)
NRC Compliance Bulletin.No. 87-02:
"Fastener Testing to Determine Conformance with Applicable Material Specifications."
On December 2,
1987 the inspector participated in. the licensee's selection. of a sample of safety grade and non-safety grade bolts and studs pursuant to the instructions of-Actions 2 and 3 of the Bulletin.
The following were noted:
(1)
the sample was of sufficient numerical size; (2)
the sample was selected roughly in proportion to inplant use; and, (3)
a variety of sizes and manufacturers were represented in the sample.
Safety grade bolts and studs were predominantly A-193 grades B7 and B8, nuts were predominantly A-194.
No cases were noted where markings (manufacturer, specification or grade)
were absent when they were required by applicable specification.
No bolts were found with manufacturer's marks of particular interest as identified to the inspector as part of inspection instructions'icensee performance of remaining Actions 1, 4, 5 and 6 will be reviewed in a future inspection.
b.
(Closed)
Generic Letter 87-06: "Periodic Verification of Leak Tight Integrity of Pressure. Isolation Valves" dated March 13, 1987.
The licensee responded to this Generic Letter on November 12, 1987 (AEP:NRC: 1041), later than the requested response date.
A submittal due date extension was discussed with the Licensing Project Manager for NRC.
The Generic Letter solicits information to verify reactor coolant pressure boundary (RCPB) integrity is appropriately monitored as it relates to dual series pressure isolation valves (PIVs), between the reactor coolant and any attached low pressure system(s).
The PIVs were to be identified and their associated integrity testing described, to include: test type; test frequency; test acceptance criteria; and operational limits as applicable.
The inspector review indicated the licensee's response included a
complete list of PIVs in the plant, totalling 46 valves per Unit.
Four valves per Unit are specifically called out by Technical Specifications pursuant to an NRC Order (the "Event V" Order) dated April 20, 1981.
All requested information appeared to be present for these valves.
Nineteen valves per Unit are reportedly leak tested each refueling pursuant to ASME Boiler and Pressure Vessel Code,Section XI, IWV-3420 and -3422.
Acceptance criteria are established.
Operational limits are inherent in existing Technical Specifications.
Twenty-two valves are reportedly not leak tested.
In each case, valve performance during operation (i.e., tightness)
is monitored via instrumentation installed on the downstream piping (acoustic or temperature monitors) or in 'the downstream receiver volume (level, temperature, pressure, humidity, radiation), or both.
The ASME Codes',
Se'ction XI, IWV-3421 exempts from leak testing those valves which demonstrate functionally adequate leak tightness during operations.
These 22 valves appear to qualify for this exemption, but the, licensee's submittal makes no specific reference or claim regarding exempt status.
A single valve in each Unit (1-IMO-128 for Unit 1, 2-IMO-128 for Unit 2) is not leak tested and the inspector could not identify an obvious basis for exemption.
The subject valve is the inboard valve of a pair from the loop 2 hot leg to the residual heat removal (RHR)
system.
A number of pieces of information are given relating to the need for testing, including: the outboard valve is tested; both valves are interlocked to remain closed above 410 psi; the valve auto-closes at or above 600 psi; and, a 900 gpm capacity safety valve set at 450 psi is located downstream.
Though this information suggests no substantial leak past this valve would go undetected for long, no specific claim regarding exempt status is made in the licensee's submittal.
The NRC Office of Nuclear Reactor Regulation will make the final determination whether the licensee's current testing programs are adequate or need to be modified.
No violations, deviations, unresolved or open items were identified.
11.
0 en Items Open Items are matters which have been discussed with the licensee, which will be reviewed further by the inspector, and which involve some action on the part of the NRC or licensee or both.
An open item disclosed during the inspection is discussed in Paragraph 6.e.
12.
Nana ement Interview The inspectors met with licensee representatives (denoted in Paragraph'1)
on December 15, 1987 to discuss the scope and findings of the inspection.
In addition, the inspector asked those in attendance whether they considered any of the items discussed to contain informat,ion exempt from disclosure.
No items were identified.
The following items were specifically discussed:
a.
items identified on tours as much improved or as needing attention (Paragraph 3);
b.
the interpretation of Technical Specifications involving permissible bypass of Reactor Trip Breakers (Paragraph 3);
C.
d.
e.
maintenance activities and trending on steam generator blowdown valves, including an Open Inspection Item relating to qualification of repair/replacement parts (Paragraph 5)",
main steam safety valve surveillance, related Unit Technical Specification inconsistencies,,
and compliance to the intent that orifice size not be changed (Paragraph 6);
an apparent procedure proviso allowing waiver of Techni'cal Specification limiting conditions and licensee action to correct this (Paragraph 6);
review of actions on previously identified items (Paragraph 2) and two Licensee Event Reports (Paragraph 9);
review of actions on an NRC Bulletin and a Generic Letter (Paragraph 10),
16