SUBJECT:

SURRY POWER STATION - SECURITY BASELINE INSPECTION REPORT 05000280/2025402 AND 05000281/2025402

Dear Eric Carr:

On April 10, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Surry Power Station and discussed the results of this inspection with James Shell and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Jannette G. Worosilo, Chief Nuclear Security Branch Division of Fuels, Radiological Safety, and Security Docket Nos. 05000280 and 05000281 License Nos. DPR-32 and DPR-37

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000280 and 05000281

License Numbers:

DPR-32 and DPR-37

Report Numbers:

05000280/2025402 and 05000281/2025402

Enterprise Identifier:

I-2025-402-0023

Licensee:

Virginia Electric and Power Company

Facility:

Surry Power Station

Location:

Surry, VA

Inspection Dates:

April 7, 2025, to April 10, 2025

Inspectors:

J. Stovall, Physical Security Inspector

R. Womack, Senior Physical Security Inspector

Approved By:

Jannette G. Worosilo, Chief

Nuclear Security Branch

Division of Fuels, Radiological Safety, and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a security baseline inspection at Surry Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

SAFEGUARDS

71130.04 - Equipment Performance, Testing, and Maintenance

The inspectors evaluated the security equipment testing and maintenance program through completion of the following procedure elements:

Equipment Performance, Testing, and Maintenance (1 Sample)

(1)

  • Tier I: All requirements
  • Tier II: 02.09 a., b.; 02.11 a., d.
  • Tier III: 02.15 a., c.

71130.07 - Security Training

The inspectors evaluated the security training program through completion of the following

procedure elements: Security Training

(1)

  • Tier I: All requirements
  • Tier II: 02.05 a., c.; 02.07 a.; 02. 09 a., b.
  • Tier III: 02.10; 02.11 a.; 02.13 a., c.; 02.14 a.

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On April 10, 2025, the inspectors presented the security baseline inspection results to James Shell and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

CR1232640

CR1235227

Corrective Action

Documents

CR1281389

Corrective Action

Documents

Resulting from

Inspection

CR1288319

Weapons Maintenance Records (Samples)

23 Annual

Barrier Inspection

24 Annual

Barrier Inspection

Annual Inspection

23 Security

Equipment

Armorer

Certifications

M. Church,
N. Mitchell,
L. Murray, T. Smith

Delta Annual

Inspections 2024

Security Shift

Blotter

Selected dates in November 2024

Security Shift

Blotter

Selected dates in February 2024

Security Shift

Blotter

Selected dates in October 2023

Bravo Team 4/9/2025

Miscellaneous

Surry Nuclear

Power Station

Weapons Sign

Out Log

Alpha Team 4/9/2025

0-OSP-SE-001

Security Forward Access Point Diesel Generator Operability

Test

Revision 10

71130.04

Procedures

0-OSP-SE-003

Security Diesel Generator Undervoltage Test

Revision 8

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

IR Post

Installation Test

Procedure

Section 4.6 Post Installation Test Procedure

SY-AA-116

Maintenance, Testing, and Calibration

Revision 8

SY-AA-120

Operability Testing

Revision 13

SY-AA-TR-102

Weapons Accountability, Testing, and Maintenance

Revision 14

XField Product

Guide

XField Pd Testing

204294988

Month Freq. PT: Security Emerg. Diesel Undervoltage

09/01/2023

204321936

PT: Security Diesel Generator Test

09/01/2023

Work Orders

204333917

PT: Security Emerg. Diesel Undervoltage

2/13/2025

Corrective Action

Documents

CR1220705

Corrective Action

Documents

Resulting from

Inspection

CR1288319

Security Officer Training Records (Samples)

Tactical Course Score Sheets (Samples)

Dominion

Security

Fleet Annual Exam, Tests #1 & #2

Revision 3

Instructor

Certifications

M. Church,
D. Keaton,
N. Mitchell,
L. Murray, T. Smith

Lesson Plan CT

Perform Nonlethal Defense Measures

Revision 0

Lesson Plan CT

Demonstrate Use of Protective Equipment

Revision 1

Lesson Plan CT

Perform Tactical Qualification Course

Revision 14

Rifle Day Light Qualification Course (Surry)

Rifle Low Light Qualification Course (Surry)

71130.07

Miscellaneous

NRA Law

Enforcement

Course of Fire

Review &

Approval

Rifle Thermal Qualification Course (Surry)

10/14/2022

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Application

Training

Presentation

Suspicious Activity Reporting

Revision 1

SY-AA-138

Suspicious Activity Reporting

Revision 0

SY-AA-TR-101

Nuclear Security Training Program

Revision 17

Procedures

SY-AA-TR-205

On-the-Job Training/Task Performance Evaluation

(OJT/TPE) Process

Revision 6