March 11, 2025

SUBJECT:

ANNUAL ASSESSMENT LETTER FOR OCONEE NUCLEAR STATION -

UNITS 1, 2 AND 3 (NRC INSPECTION REPORT 05000269/2024006, 05000270/2024006, AND 05000287/2024006)

Dear Steven Snider:

The NRC has completed its end-of-cycle performance assessment of Oconee Nuclear Station, Units 1, 2 and 3, reviewing performance indicators (PIs), inspection results, and enforcement actions from January 1, 2024, through December 31, 2024. This letter informs you of the NRCs assessment of your facility during this period and its plans for future inspections at your facility.

The NRC concluded that overall performance at your facility preserved public health and safety.

The baseline inspection program was completed at your facility as defined in Inspection Manual Chapter 2515, Light-Water Reactor Inspection Program - Operations Phase.

The NRC determined the performance at Oconee Nuclear Station, Units 1, 2, and 3, during the most recent quarter was within the Licensee Response Column, the highest performance category of the NRCs Reactor Oversight Process (ROP) Action Matrix, because all inspection findings had very low safety significance (i.e., Green), and all PIs were within the expected range (i.e., Green). Therefore, the NRC plans to conduct ROP baseline inspections at your facility.

The enclosed inspection plan lists the inspections scheduled through December 31, 2026. The NRC provides the inspection plan to allow for the resolution of any scheduling conflicts and personnel availability issues. Routine inspections performed by resident inspectors are not included in the inspection plan. The inspections listed during the last 12 months of the inspection plan are tentative and may be revised. The NRC will contact you as soon as possible to discuss changes to the inspection plan should circumstances warrant any changes.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Please contact me at 404-997-4664 with any questions you have regarding this letter.

Sincerely, Robert E. Williams, Jr., Chief Projects Branch 1 Division of Operating Reactor Safety Docket Nos. 05000269, 05000270 and 05000287 License Nos. DPR-38, DPR-47 and DPR-55 Enclosure:

Oconee Inspection Plan (3/1/2025 - 12/31/2026)

cc: Distribution via ListServ Signed by Williams, Robert on 03/11/25

ML25065A269 X

SUNSI Review X

Non-Sensitive

Sensitive X

Publicly Available

Non-Publicly Available OFFICE RII/DORS RII/DORS NAME J. Seat R. Williams DATE 03/07/25 03/11/25

Site Inspection Activity Plan Enclosure 07200004 - Oconee (ISFSI)

03/01/2025 - 12/31/2026 ISFSI LICENSE RENEWAL

Unit Start End Activity CAC Title Staff Count 4/28/2025 5/2/2025 IP 60859 001921 Independent Spent Fuel Storage Installation (ISFSI) License Renewal Inspection

Site Inspection Activity Plan

Oconee 03/01/2025 - 12/31/2026 SECURITY BASELINE INSPECTION

1,2,3 3/17/2025 3/20/2025 IP 71130.01 000733 Access Authorization 1,2,3 3/17/2025 3/20/2025 IP 71130.02 000734 Access Control 1,2,3 3/17/2025 3/20/2025 IP 71130.08 000740 Fitness-For-Duty Program 1,2,3 3/17/2025 3/20/2025 IP 71130.09 001656 Security Plan Changes 1,2,3 3/17/2025 3/20/2025 IP 71151 001338 Performance Indicator Verification 1,2,3 3/17/2025 3/21/2025 SGT 000981 FB-OR-Security Inspection Travel (SGT)

EMERGENCY PREPAREDNESS PROGRAM INSPECTION

1,2,3 4/7/2025 4/11/2025 IP 71114.02 000717 Alert and Notification System Testing 1,2,3 4/7/2025 4/11/2025 IP 71114.03 000718 Emergency Response Organization Staffing and Augmentation System 1,2,3 4/7/2025 4/11/2025 IP 71114.04 000719 Emergency Action Level and Emergency Plan Changes 1,2,3 4/7/2025 4/11/2025 IP 71114.05 000720 Maintenance of Emergency Preparedness 1,2,3 4/7/2025 4/11/2025 IP 71151 001397 Performance Indicator Verification PROBLEM IDENTIFICATION AND RESOLUTION

1,2,3 4/14/2025 4/18/2025 IP 71152B 000747 Problem Identification and Resolution 1,2,3 4/28/2025 5/2/2025 IP 71152B 000747 Problem Identification and Resolution ISFSI LICENSE RENEWAL

1,2,3 4/28/2025 5/2/2025 IP 60859 Independent Spent Fuel Storage Installation (ISFSI) License Renewal Inspection CYBER SECURITY INSPECTION

1,2,3 7/28/2025 8/1/2025 IP 71130.10 000741 Cybersecurity FOCUSED ENGINEERING INSPECTION (CGD)

1,2,3 9/8/2025 9/12/2025 IP 71111.21N.03 001808 Commercial Grade Dedication 1,2,3 9/22/2025 9/26/2025 IP 71111.21N.03 001808 Commercial Grade Dedication RP OCCUPATIONAL RADIATION SAFETY BASELINE INSPECTION

1,2,3 11/3/2025 11/7/2025 IP 71124.01 000725 Radiological Hazard Assessment and Exposure Controls 1,2,3 11/3/2025 11/7/2025 IP 71124.03 000727 In-Plant Airborne Radioactivity Control and Mitigation 1,2,3 11/3/2025 11/7/2025 IP 71124.04 000728 Occupational Dose Assessment 1,2,3 11/3/2025 11/7/2025 IP 71124.05 000729 Radiation Monitoring Instrumentation 1,2,3 11/3/2025 11/7/2025 IP 71151 000746 Performance Indicator Verification 1,2,3 11/17/2025 11/21/2025 IP 71124.01 000725 Radiological Hazard Assessment and Exposure Controls 1,2,3 11/17/2025 11/21/2025 IP 71124.03 000727 In-Plant Airborne Radioactivity Control and Mitigation MATERIAL CONTROL AND ACCOUNTING

1,2,3 7/21/2025 7/25/2025 IP 71130.11 000742 Material Control and Accounting (MC&A)

Unit Start End Activity CAC Title Staff Count

Site Inspection Activity Plan

1,2,3 11/17/2025 11/21/2025 IP 71124.04 000728 Occupational Dose Assessment 1,2,3 11/17/2025 11/21/2025 IP 71124.05 000729 Radiation Monitoring Instrumentation 1,2,3 11/17/2025 11/21/2025 IP 71151 000746 Performance Indicator Verification UNIT 2 IN-SERVICE INSPECTION +SG

FOCUSED ENGINEERING INSPECTION (FPTI)

1,2,3 1/12/2026 1/16/2026 IP 71111.21N.05 001646 Fire Protection Team Inspection (FPTI)

1,2,3 1/26/2026 1/30/2026 IP 71111.21N.05 001646 Fire Protection Team Inspection (FPTI)

FORCE-ON-FORCE PLANNING AND EXERCISE WEEKS - OCO

1,2,3 2/9/2026 2/13/2026 IP 71130.03 000735 Contingency Response - Force-On-Force Testing 1,2,3 2/9/2026 2/13/2026 SGT 000981 FB-OR-Security Inspection Travel (SGT)

1,2,3 3/2/2026 3/6/2026 IP 71130.03 000735 Contingency Response - Force-On-Force Testing 1,2,3 3/2/2026 3/6/2026 SGT 000981 FB-OR-Security Inspection Travel (SGT)

SECURITY BASELINE INSPECTION

1,2,3 4/20/2026 4/23/2026 IP 71130.02 000734 Access Control 1,2,3 4/20/2026 4/23/2026 IP 71130.04 000736 Equipment Performance, Testing, and Maintenance 1,2,3 4/20/2026 4/23/2026 IP 71130.07 000739 Security Training 1,2,3 4/20/2026 4/23/2026 IP 71130.09 001656 Security Plan Changes 1,2,3 4/20/2026 4/23/2026 IP 71151 001338 Performance Indicator Verification 1,2,3 4/20/2026 4/24/2026 SGT 000981 FB-OR-Security Inspection Travel (SGT)

UNIT 3 IN-SERVICE INSPECTION +SG

3 5/11/2026 5/22/2026 IP 71111.08P 000702 Inservice Inspection Activities (PWR)

RP OCCUPATIONAL RAD SAFETY AND TRANSPORTATION BASELINE INSPECTION

1,2,3 5/11/2026 5/15/2026 IP 71124.01 000725 Radiological Hazard Assessment and Exposure Controls 1,2,3 5/11/2026 5/15/2026 IP 71124.08 000732 Radioactive Solid Waste Processing & Radioactive Material Handling, Storage, & Transportation 1,2,3 5/11/2026 5/15/2026 IP 71151 000746 Performance Indicator Verification OPERATION OF AN ISFSI

1,2,3 7/20/2026 7/24/2026 IP 60855 001001 Operation Of An ISFSI EMERGENCY PREPAREDNESS EXERCISE INSPECTION

1,2,3 8/17/2026 8/21/2026 IP 71114.04 000719 Emergency Action Level and Emergency Plan Changes 1,2,3 8/17/2026 8/21/2026 IP 71114.07 000722 Exercise Evaluation - Hostile Action (HA) Event 1,2,3 8/17/2026 8/21/2026 IP 71151 001397 Performance Indicator Verification RP PUBLIC RAD SAFETY BASELINE INSPECTION

1,2,3 8/31/2026 9/4/2026 IP 71124.06 000730 Radioactive Gaseous and Liquid Effluent Treatment 1,2,3 8/31/2026 9/4/2026 IP 71124.07 000731 Radiological Environmental Monitoring Program 1,2,3 8/31/2026 9/4/2026 IP 71151 000746 Performance Indicator Verification

11/10/2025 11/21/2025 IP 71111.08P 000702 Inservice Inspection Activities (PWR)

Site Inspection Activity Plan

OCONEE INITIAL LICENSE EXAM

1,2,3 8/9/2026 8/15/2026 OV 000956 FB-OR-Onsite Validation Of Initial License Examination (OV)

1,2,3 9/13/2026 9/26/2026 EXAD 000500 FB-OR-Initial License Exam Administration (EXAD)

UNIT 1 IN-SERVICE INSPECTION +SG

1 11/9/2026 11/20/2026 IP 71111.08P 000702 Inservice Inspection Activities (PWR)