APPENDIX B U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

!

NRC Inspection Report: 50-267/89-06 Operating License: DRP-34 Docket: 50-267 l Licensee: Public Service Company of Colorado (PSC)

L P.O. Box 840 Denver, Colorado 80201-0840 Facility Name: Fort St. Vrain Nuclear Generating Station (FSV) *

Inspection At: FSV, Platteville, Colorado Inspection Conducted: March 13-17, 1989 Inspector; J. A. F. Kelly, Senior Sec ity Inspector be?[ k Date 4 (decdrityandEmergencyPreprednessSection I

.

Approved: /d M/tt?// / ate 2M h/

R. J. Everett,' Chief./ ecurity S and Emergency ' q p Preparedness Sectich -

Inspection Summary Inspection Conducted March 13-17, 1989 (Report 50-267/89-06)

l Areat Inspected: Routine, unannounced inspection of the licensee's physical security program., The areas inspected withir, the physical security program .

included managcraent support and security program plan; protected and vital area (VA) oarriers, detection and assessment aids; orotected and VA acces'.,

control of perscnnel, packages, and vehicles; alarm stations and ,

communications; and testing, maintenance, and comperaatory.measure )

Results: Within the program areas inspected, one violction was identified i (inadequate access control - personnel, paragraph 3).

During this inspection period, the licensee experienced one reportable event I (LER 267/89-501) as discussed in carag'.eph 2. Based on a reviev cy the NRC  ;

inspector, LER 267/89-501 was converted to Violation 267/8906-0 ;

i I:nmediate corrective action was taken with regard to Violation 267/8906-01, hewever, the root cause of the problem was not addressed. The NRC insoector j determined that the violation occurred because of several failures to follow an ]

existing security procedur In addition, implementation of the procedure -

J was not reviewed in sufficient detail to recognize the need for revision of that procedure, associated pr g g g g porting hardware,

'

gp2ggggggggg267 ' ' l