Text
- _ - - . - - _
i
MM - 91989
D0cuMENT coNTAINS
4
>
MGUARDS INFORMATION
In Reply Refer To:
Docket:
50-267/89-06
Public Service Company of Colorado
. ATTN:
Robert O. Williams, Jr. , Senior
<
Vice President, Nuclear Operations
P.O. Box 840
Denver, Colorado 80201-0840
Gentlemen:
.This refers to the inspection conducted by Mr. J. A. F. Kelly of this office
during the period March 13-17, 1989, of activities authorized by NRC Operating
. License DPR-34 for Fort St. Vrain Nuclear Generating Station, and to the
discussion of our findings with Mr. C. Fuller and other members of your staff
at the conclusion of the inspection.
The inspection reviewed certain areas of your physical security program.
.Within these areas, the inspection consisted of selective examination of
procedures and representative records, interviews with personnel, and
observations by the NRC inspector. The areas inspected and the inspection
findings are documented in the enclosed inspection report.
During this inspection, it was found that certain of your activities were in
violation of NRC requirements.
Consequently, you are required to respond to
this violation, in writing, in accordance with the provisions of Section 2.201
of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal
Regulations. Your response should be based on the specifics contained in the
Notice of Violation enclosed with this letter.
The material enclosed herewith contains Safeguards Information as defined by
10 CFR Part 73.21 and its disclosure to unauthorized individuals is prohibited
by Section 147 of the Atomic Energy Act of 1954, as amended.
Therefore, the
material, with the exception of the report cover page which is an inspection
summary, will no_t be placed in the Public Document Room.
-
The response directed by this letter and the accompanying Notice is not subject
to the clearance procedures of the Office of Management and Budget as required
3
by the Paperwork Reduction Act of 1980, PL 96-511.
!
j
8905220444 990509
}9
-
{DR
ADOCK 050
7
..
,
l
C:RPB
5 :D }
D:Ck
QjlJ PS:RPB
C:SEPS \\
.
l
JKelly:jt
JEverett
9
BMurray
Bel .i
LJCallen
Q g61/89
g
/89
f/./89
34 /89
J'/ g/89
/
l
l
ENCL.0SURE CONTAINS
SAFEGUARDS INFORMATION
DOCUMENT 00NTAINS
UPON SEPARATION THIS
,I
SAFEGUARDS INFORMATION
PAGE IS DECONTROLLED
[68
- ._
- - - _ _ - -_
_
-
-
- - - -
--- -
. ,
_
_ _ _ _
_ _ _ _ _ _ _ _ . _ _
- ,. .,bi
.
.
Public~ Service Company' of Colorado
-2-
S
.Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Sincerely,
Origina.~ Signed By
L. J. Callan
L. J. Callan, Director
Division of Reactor Projects
Enclosures:
1.
Appendix A:- Notice of Violation
2.
Appendix B - NRC Inspection Report
50-267/89-06
cc w/ summary page only:
Fort St. Vrain Nuclear Station
ATTN:
C. Fuller,. Manager, Nuclear
Production Division
16805.WCR 19
Platteville, Colorado 80651
' Fort-St. Vrain Nuclear Station
ATTN:
P. Tomlinson, Manager-
Quality Assurance Division
16805 WCR 19
Platteville, Colorado 80651
Colorado.Public Utilities Commission
l
ATTN:
Ralph Teague, P.E.
j
1580 Logan Street OLI
J
. Denver, Colorado 80203
J
Colorado Radiation Control Program Director
bcc copy of entire report:
i
RIV Security File
l
P. A.; Starcher, RSGB/NRR
1
R.'D.- Martir., RA
l
B. Beach,'DRSS
i
'
Chief, RPB
Section Chief., SEPS:RPB
2
Security Inspector.
ResHent Inspector
i
SEPJ RPB File
i
G. F._Sanborn, E0
1
D. M. Crutchfield, NRR
l
1
ENCLOSURE CONTAINS
1
SAFEGUARDS INFORMATION
l
DOCUMENT CONTAINS
UPON SEPARATION THIS
SAFEGUARDS INFORMATION
PAGE IS DECONTROLLED
i
1
-
m_________________________
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_;
- _ _ - _ - - _
_ - - _ - _ - - - - _ _ _ _
_ - _ _
__ _
_ _ _
._-_ _
-
ie
,iA
s t
, ,
Public Service Company of. Colorado.
-3-
bec copy of letter;and inspection' summary only w/765:
'
- DRP
MIS ~
- RSTS Operator
Lisa Shea, RM/ALF
Section Chief, DRP/B
RIV File
-
R. E. Hall, DRSS
.
Project Engineer, DRP/B
.
bec copy of letter and inspection summary only w/out 766:
- DMB IE-04
DRS-
K. Heitner, NRR. Project Manager
V
l
ENCLOSURE CONTAINS
SAFEGUARDS INFORMATION
UPON SEPARATION THIS
PAGE IS DECONTROLLED
_ _ _ _ .
_ _ _ _
_ - - - -