IR 05000249/1976020

From kanterella
Jump to navigation Jump to search
Letter Regarding Steps Taken by Commonwealth Edison to Correct Noncompliance Identified in 10/20/1976 Letter - Dresden Unit 3 Inspection Report 05000249/1976020
ML17252B140
Person / Time
Site: Dresden Constellation icon.png
Issue date: 12/23/1976
From: Fiorelli G
NRC/RGN-III
To: Brian Lee
Commonwealth Edison Co
References
IR 1976020
Download: ML17252B140 (3)


Text

......

..... ~. ~-.~-....:..~:-i......... _*~ ___

._~*-*:_---*-**

.;.

... -*-. *... -.....:..-.. ---... : -*.

.:.~_;___ ___ ; :.........

,.

i :~.:

~

.. *----.***--*-**-*--.*--*** -*-* -***- ---*--=--. -~*ik."~.. l~

--*--*---*--

....,..~.-~:~L::~~t:~:.~ __ :.:_ __

. -.--.. -

-

- --

--**.... -

~

.,.;

~-

.,

~

,...-.**.*

ii::.

UNITED STATES NUCLEAR REGULATORY. COMMISSION REGION Ill 799 ROOSEVELT ROAD GLEN ELLYN, ILLINOIS_ 60137 DEC 2 3 1976-CENTRAL Fl LES Commonwealth.Edison Company ATTN:

Mr. Byron Lee, Jr.

Docket No. 50-249 Vice President P.O. Box 767 Chicago, Illinois

~0690 Gentlemen:

Thank you for your letter da~ed December 9, 1976, informing us /of tlie steps you have taken. to correct.the noncompliance identified in our letter dated October 20, 1976.

We will examine your corrective.,action during a future inspection.

Your cooperation with us is appreciated.

cc:

Mr. B :. B. Stephenson..

Station Superi.ntendent cc w/lti <ltd 12/9/76: *

Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC TIC Anthony. Roisman, Esq.,

Attorney

Sincerely yours,

. ~.,,

--<i~;-_..4~/~'

~c./

~C" u:,t::-e-<-

Gaston Fiorelli, Chief Reactor Operations and N.uclear Support Branch-9*

'>.

Commonwealth Edison *

One First National Plaza, Chicago, lliinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690

.Mr *. James G. Keppler,. Director Directorate of' Inspection and*

Enforcement - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 December 9, 1976 Subject:

Dresden Station.Unit 3 IE InspectionfReport 50-249/76~20 1-TRC Docket No~ 50-'249 Reference (a) :

R. L. Bolger (CECo) Le.tter to J. G~.. Keppler (NRC} dated November 8, 1976 -

NRC Dkt. 50-249.

Dear.Mr. Keppler:

In response to subsequent discussi6ns with your* inspector, the Dresden Station refueling interlock.s.urveillance procedure a:qd the.Dresden Station fuel handling procedures have been reviewed.

As a result, the follo\\*1ing further procedu-r:e revisions will be made prior to.the next Unit 2 or Unit 3 re~-q.e,ling outage *

. 1. *Procedure DOS 800-1, "Refueling Interlock Check,; step F. 2.g.,

will be revised.

This rev'isiori will specify a new test weight value *which ensures, regar¢l).ess of*' grapple position, a grapple loaded signal will be present whenever a fuel assembly is on the grapple.

2.

Procedur.es DFP 800-7, "Fuel Handling Inside the Reactor" step

.F.l.i; DFP 800-9, "Fuel Movements From the Spent Fuel Storage Pool to the Reacto:i::" step F.1.1; and DFP 800-10, "Fuel r.fovements

,From,the Reactor to the St0rage Pool" step F.1. h; will be re-

. vised *. These revisions will insert a caution directing the operator not to raise. a fuel assembly if the HOIST LOADED light lails to illuminate.

  • This matter is not directly related to the noncompliance i:tem identified in the subject inspection report.

As. described in iefer~~ce (a}, it is our judgemen~ that ~tis not necessary to observe 'the hoist loadcp light. to verify. a*.fuel assemble is "moving.

up" *. This matter concerns the adequacy of the Dresden Station procedures for verification of refueling interlocks.

It is our

. OEC l 3.. i976

  • Commonwealth Edison C~m pany Mr. James ~

\\

'vi;

--2 -

Decembe~ 9,. 197.6

' '!;

,,3:tadgement that the existing procedures were adequate to prevent inadvertent criticality during core alterations ;-*;howev:er,_the _

procedure revisions described in the preceding paragraph should provide further assurance.

As requested by your "inspector I this information is submitted in the forin of a supplement to Reference (a) *

Please direct any further questions on thi.s matter to.thi.s *

office.

This letter contains no proprietary information.

very truly your_s,

$&~'1 R. L. Bolger

.

Assistant Vice Pr.esident

.,.