ENS 51499
ENS Event | |
|---|---|
05:00 Oct 26, 2015 | |
| Title | Nuclear Density Gauge Potentially Damaged During Shipment |
| Event Description | The following report was provided by the Louisiana Department of Environmental Quality via email:
On 10/26/2015, [The] RSO [Radiation Safety Officer] / Technical Service Manager for QSA Global notified the LDEQ [Louisiana Department of Environmental Quality] about an incident where a [common carrier] delivered a device containing radioactive material to their facility on Langley Dr., Baton Rouge, LA. When the receipt surveys were being performed, they noticed at one point on the surface they had a reading of 2 R/hr at the surface. It appears that one or more of the pull ties used to secure the shutters on the device broke causing a shift in the shielding. Part of the bracing material minimized the shielding shift. The device in question is a Texas Nuclear level/density gauge, Model # 5210, SN B1110, loaded with [approximately] 733 mCi of Co-60 sealed source. The origin of the shipment was Puerto Ordaz, EDO Bolivar, Venezuela. It came stateside via [common carrier] to Houston, TX and then to the QSA Global facility in Baton Rouge, LA by [common carrier]. The shipment arrived [at approximately] 1145 [CDT] on 10/26/2015. The activity is below Cat 2 quantities at [approximately] 733 mCi of Co-60. The device was surveyed and moved to a bunker on the QSA Global site. Re-enactments and calculations will be conducted on 10/27/2015 AM when [the RSO] is present. The LDEQ personnel will be on site for the measurements, calculations and follow-up information [dissemination]. This is a preliminary notification of an incident reported to LDEQ [at approximately] 1530 [CDT]. After the source was secure, safe and locked in a bunker at the QSA Global Baton Rouge, LA facility. Possible exposure calculations will be determined from the reconstruction of events. The Baton Rouge facility is compliant for the IC [Increased controls] principles and Radiation Safety procedures/aspects for the receipt activities. The Department, LDEQ personnel will be on site for the corrective actions and calculations. The NRC, Region IV, was made aware of this situation on 10/26/2015. Follow-up information will be [disseminated] when available. This is being reported as a preventive and protection action under 10 CFR Part 30.50(a). Information will be updated when available. LDEQ considers this incident still open. Event Report ID No.: LA-150019 |
| Where | |
|---|---|
| Qsa Global, Inc. Baton Rouge, Louisiana (NRC Region 4) | |
| License number: | LA-5934-L01 A |
| Organization: | Louisiana Radiation Protection Div |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+14.63 h0.61 days <br />0.0871 weeks <br />0.02 months <br />) | |
| Opened: | Joe Noble 19:38 Oct 26, 2015 |
| NRC Officer: | Jeff Herrera |
| Last Updated: | Oct 26, 2015 |
| 51499 - NRC Website | |
Qsa Global, Inc. with Agreement State | |
WEEKMONTHYEARENS 575922025-03-05T05:00:0005 March 2025 05:00:00
[Table view]Agreement State Leaking Sealed Source ENS 560302022-07-25T04:00:00025 July 2022 04:00:00 Agreement State Lost/Missing Category 2 Radioactive Material Shipment ENS 557952022-03-18T17:06:00018 March 2022 17:06:00 Agreement State Lost Package Containing Radioactive Material ENS 555472021-10-26T20:50:00026 October 2021 20:50:00 Agreement State Radiography Camera Delivered to Wrong Address ENS 551632021-03-31T14:44:00031 March 2021 14:44:00 Agreement State Sealed Source Missing in Transit ENS 551192021-03-01T19:00:0001 March 2021 19:00:00 Agreement State Category 2 Package Containing Seven Sealed Sources Lost in Transit ENS 551122021-02-23T17:00:00023 February 2021 17:00:00 Agreement State Lost Source ENS 532332018-02-28T15:30:00028 February 2018 15:30:00 Agreement State Agreement State Report - Package Containing Category 2 Sealed Sources Missing in Transit ENS 523912016-11-03T06:00:0003 November 2016 06:00:00 Agreement State Agreement State Report - Leaking Kr-85 Source During Transfer to Approved Shipping Container ENS 518252016-03-26T04:00:00026 March 2016 04:00:00 Agreement State Agreement State Report - Missing Shipment of Radioactive Materials ENS 514992015-10-26T05:00:00026 October 2015 05:00:00 Agreement State Nuclear Density Gauge Potentially Damaged During Shipment ENS 508202015-02-13T17:35:00013 February 2015 17:35:00 Agreement State Agreement State Report - Cat 1 Iridium-192 Shipment Lost/Found During Transit ENS 507352015-01-14T18:47:00014 January 2015 18:47:00 Agreement State Agreement State Report - Two Category 2 Iridium Sources Unaccounted for During Shipment ENS 504582014-08-06T04:00:0006 August 2014 04:00:00 Agreement State Agreement State Report - Manufacturing Defect Resulting in Equipment to Not Perform as Designed ENS 465792011-01-26T05:00:00026 January 2011 05:00:00 Agreement State Agreement State Report - Missing Radioactive Material Shipment ENS 464082010-11-08T05:00:0008 November 2010 05:00:00 Agreement State Agreement State Report - Radioactive Material Shipment Fails to Arrive ENS 444302008-08-20T20:41:00020 August 2008 20:41:00 Agreement State Massachusetts Agreement State Report - Radiation Greater than Ten Times Limit 2025-03-05T05:00:00 | |