ENS 55795
ENS Event | |
|---|---|
17:06 Mar 18, 2022 | |
| Title | Lost Package Containing Radioactive Material |
| Event Description | The following was received via email from the Massachusetts Radiation Control Program:
At 1338 EDT today (3/18/2022), QSA Global, Inc. contacted the Radiation Control Program to report a potential missing package containing radioactive material. The package is a QSA Global 880 source changer and overpack containing a single Ir-192 source with an activity of 6.6 curies (assay date 2/15/2022), [serial number] SN: 31468M. The 880 source changer SN is C010. The package was shipped via common courier from Acuren Group, Inc. in Edmonton, Canada on February 15, 2022. On March 3, 2022, package was scanned at the common courier terminal in Memphis, TN (last known location). On March 9, 2022, Acuren contacted QSA Global, Inc. in Baton Rouge, Louisiana to inform them that the package could not be located. On March 11, 2022, Acuren contacted QSA Global, Inc. in Louisiana and the common courier for a status. The common courier initiated a search on March 11, 2022, that included the common courier main hub in Memphis, TN. The package could not be located. At 0930 EDT this morning (3/18/2022), common courier contacted the QSA Global Baton Rouge office and notified them that the package could not be located. At 1206 EDT today (3/18/2022) the Baton Rouge office contacted QSA Global, Inc. in Burlington, MA to notify them of the missing package. The Massachusetts Radiation Control Program considers this event as open pending further investigation.
The following received via email from the Massachusetts Radiation Control Program: Upon Agency (Massachusetts Radiation Control Program) discussion with state of Tennessee, who had contacted the common carrier's Dangerous Goods Administration, the carrier reported on March 22, 2022, the package to be located at the carrier's Custom clearance area at its hub in Memphis, TN and the package is not missing. Notified R1DO (Jackson) and NMSS Events Notification, ILTAB, and CNSNS via email. THIS MATERIAL EVENT CONTAINS A 'Category 3' LEVEL OF RADIOACTIVE MATERIAL Category 3 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for some hours. It could possibly - although it is unlikely - be fatal to be close to this amount of unshielded radioactive material for a period of days to weeks. These sources are typically used in practices such as fixed industrial gauges involving high activity sources (for example: level gauges, dredger gauges, conveyor gauges and spinning pipe gauges) and well logging. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf |
| Where | |
|---|---|
| Qsa Global, Inc. Burlington, Massachusetts (NRC Region 1) | |
| License number: | 12-8361 |
| Organization: | Ma Radiation Control Program |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+-0.35 h-0.0146 days <br />-0.00208 weeks <br />-4.7943e-4 months <br />) | |
| Opened: | Kenath O. Traegde 16:45 Mar 18, 2022 |
| NRC Officer: | Mike Stafford |
| Last Updated: | Mar 22, 2022 |
| 55795 - NRC Website | |
Qsa Global, Inc. with Agreement State | |
WEEKMONTHYEARENS 575922025-03-05T05:00:0005 March 2025 05:00:00
[Table view]Agreement State Leaking Sealed Source ENS 560302022-07-25T04:00:00025 July 2022 04:00:00 Agreement State Lost/Missing Category 2 Radioactive Material Shipment ENS 557952022-03-18T17:06:00018 March 2022 17:06:00 Agreement State Lost Package Containing Radioactive Material ENS 555472021-10-26T20:50:00026 October 2021 20:50:00 Agreement State Radiography Camera Delivered to Wrong Address ENS 551632021-03-31T14:44:00031 March 2021 14:44:00 Agreement State Sealed Source Missing in Transit ENS 551192021-03-01T19:00:0001 March 2021 19:00:00 Agreement State Category 2 Package Containing Seven Sealed Sources Lost in Transit ENS 551122021-02-23T17:00:00023 February 2021 17:00:00 Agreement State Lost Source ENS 532332018-02-28T15:30:00028 February 2018 15:30:00 Agreement State Agreement State Report - Package Containing Category 2 Sealed Sources Missing in Transit ENS 523912016-11-03T06:00:0003 November 2016 06:00:00 Agreement State Agreement State Report - Leaking Kr-85 Source During Transfer to Approved Shipping Container ENS 518252016-03-26T04:00:00026 March 2016 04:00:00 Agreement State Agreement State Report - Missing Shipment of Radioactive Materials ENS 514992015-10-26T05:00:00026 October 2015 05:00:00 Agreement State Nuclear Density Gauge Potentially Damaged During Shipment ENS 508202015-02-13T17:35:00013 February 2015 17:35:00 Agreement State Agreement State Report - Cat 1 Iridium-192 Shipment Lost/Found During Transit ENS 507352015-01-14T18:47:00014 January 2015 18:47:00 Agreement State Agreement State Report - Two Category 2 Iridium Sources Unaccounted for During Shipment ENS 504582014-08-06T04:00:0006 August 2014 04:00:00 Agreement State Agreement State Report - Manufacturing Defect Resulting in Equipment to Not Perform as Designed ENS 465792011-01-26T05:00:00026 January 2011 05:00:00 Agreement State Agreement State Report - Missing Radioactive Material Shipment ENS 464082010-11-08T05:00:0008 November 2010 05:00:00 Agreement State Agreement State Report - Radioactive Material Shipment Fails to Arrive ENS 444302008-08-20T20:41:00020 August 2008 20:41:00 Agreement State Massachusetts Agreement State Report - Radiation Greater than Ten Times Limit 2025-03-05T05:00:00 | |