ENS 44430
ENS Event | |
|---|---|
20:41 Aug 20, 2008 | |
| Title | Massachusetts Agreement State Report - Radiation Greater than Ten Times Limit |
| Event Description | [A] technician working with a 113 Ci Ir-192 source set off high radiation alarms at [the QSA Global facility] which caused the immediate evacuation of the building. Radiation surveys outside the building indicated a dose rate of approximately 3 Mr/hr at a distance of 25 feet from the exterior of the building. Radiation safety staff performed a source retrieval to recover the source and place it in a shielded container; the building was reoccupied approximately 30 minutes later.
Preliminary investigation of the technician indicated his electronic dosimeter (worn on the side of the body closest to the source) showed an exposure of 720 mRem. The technician was not wearing his extremity ring badge at the time, however the radiation safety officer calculated a maximum exposure to the tips of the maximally exposed fingers to be approximately 2 Rem. Dosimetry for both the technician involved and another that was nearby when the incident occurred have been sent to the vendor for immediate processing. Radiation Safety staff from QSA are performing additional investigations and will report back to the [MA Radiation Control Program Office] when more information becomes available. State of Massachusetts was notified by the licensee of this incident at 0621 on August 21, 2008.
The Massachusetts Radiation Control Program (RCP) has received the 30 day report from the licensee, QSA Global. This report confirms that the event which occurred on August 20, 2008 was not an overexposure event. The licensee reported levels of radiation in an unrestricted area in excess of ten times the limits specified in 105 CMR 120.221. This report was provided to the Agency (RCP) pursuant to 105 CMR 120.283. Notified R1DO (Dimitriadis) and FSME (White). |
| Where | |
|---|---|
| Qsa Global, Inc. Burlington, Massachusetts (NRC Region 1) | |
| License number: | 12-8361 |
| Organization: | Ma Radiation Control Program |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+11.63 h0.485 days <br />0.0692 weeks <br />0.0159 months <br />) | |
| Opened: | Robert Gallaghar 08:19 Aug 21, 2008 |
| NRC Officer: | Dan Livermore |
| Last Updated: | Sep 15, 2008 |
| 44430 - NRC Website | |
Qsa Global, Inc. with Agreement State | |
WEEKMONTHYEARENS 575922025-03-05T05:00:0005 March 2025 05:00:00
[Table view]Agreement State Leaking Sealed Source ENS 560302022-07-25T04:00:00025 July 2022 04:00:00 Agreement State Lost/Missing Category 2 Radioactive Material Shipment ENS 557952022-03-18T17:06:00018 March 2022 17:06:00 Agreement State Lost Package Containing Radioactive Material ENS 555472021-10-26T20:50:00026 October 2021 20:50:00 Agreement State Radiography Camera Delivered to Wrong Address ENS 551632021-03-31T14:44:00031 March 2021 14:44:00 Agreement State Sealed Source Missing in Transit ENS 551192021-03-01T19:00:0001 March 2021 19:00:00 Agreement State Category 2 Package Containing Seven Sealed Sources Lost in Transit ENS 551122021-02-23T17:00:00023 February 2021 17:00:00 Agreement State Lost Source ENS 532332018-02-28T15:30:00028 February 2018 15:30:00 Agreement State Agreement State Report - Package Containing Category 2 Sealed Sources Missing in Transit ENS 523912016-11-03T06:00:0003 November 2016 06:00:00 Agreement State Agreement State Report - Leaking Kr-85 Source During Transfer to Approved Shipping Container ENS 518252016-03-26T04:00:00026 March 2016 04:00:00 Agreement State Agreement State Report - Missing Shipment of Radioactive Materials ENS 514992015-10-26T05:00:00026 October 2015 05:00:00 Agreement State Nuclear Density Gauge Potentially Damaged During Shipment ENS 508202015-02-13T17:35:00013 February 2015 17:35:00 Agreement State Agreement State Report - Cat 1 Iridium-192 Shipment Lost/Found During Transit ENS 507352015-01-14T18:47:00014 January 2015 18:47:00 Agreement State Agreement State Report - Two Category 2 Iridium Sources Unaccounted for During Shipment ENS 504582014-08-06T04:00:0006 August 2014 04:00:00 Agreement State Agreement State Report - Manufacturing Defect Resulting in Equipment to Not Perform as Designed ENS 465792011-01-26T05:00:00026 January 2011 05:00:00 Agreement State Agreement State Report - Missing Radioactive Material Shipment ENS 464082010-11-08T05:00:0008 November 2010 05:00:00 Agreement State Agreement State Report - Radioactive Material Shipment Fails to Arrive ENS 444302008-08-20T20:41:00020 August 2008 20:41:00 Agreement State Massachusetts Agreement State Report - Radiation Greater than Ten Times Limit 2025-03-05T05:00:00 | |