ENS 52391
ENS Event | |
|---|---|
06:00 Nov 3, 2016 | |
| Title | Agreement State Report - Leaking Kr-85 Source During Transfer to Approved Shipping Container |
| Event Description | The following report was received from the Louisiana Department of Environmental Quality via email:
On the 3rd of November, 2016, QSA Global, Inc. had an incident during the transfer of Kr-85 sources to approved shipping containers for transportation to Qual-X, Inc. for recycling. The work was being preformed at approximately 1530 to 1600 hrs. [CST]. After the completion of the work, there was no indication at that time of any possible leakage. At approximately 1800 hrs., it was noticed that the scintillation counter background had a slightly higher than normal background reading. It was determined that the only possible cause was the Kr-85 sources, as that is all that QSA Global, Inc. had worked with that day. A visual inspection of the possible leaking Kr-85 sources was performed. There was no damage to any of the windows, but QSA Global, Inc. now knows that was the point of origin of the contamination due to the surveys of the lead container that they were stored in. The sources were sealed in a 10 gallon steel drum and then placed in a plastic bag to prevent any additional release of material. The sources involved are LFE Model S-70A s/n 9234 at 168 mCi, 9332 at 184 mCi and 9333 at 184 mCi. The original activity of these sources was 1200 mCi. The building was ventilated using fans to remove the Kr-85 that had accumulated in the building. The building was surveyed at 0230 hrs. [on November 4, 2016] with no contamination detected. Another survey of the building was performed again at 0530 again with no contamination found. After QSA Global discussed the situation with Qual-X, Inc. and using their expertise in these types of situations, it was determined from survey readings and building size, that an estimated amount of less than 1-2 mCi may have been released. They also indicated that the sources were of the type that are known to leak due to the way they are manufactured and their age being 29 years. At this point QSA Global, Inc. believes that all three may be leaking. Event Report ID No.: LA160015 |
| Where | |
|---|---|
| Qsa Global, Inc. Baton Rouge, Louisiana (NRC Region 4) | |
| License number: | LA-5934-L01 |
| Organization: | Louisiana Radiation Protection Div |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+483.35 h20.14 days <br />2.877 weeks <br />0.662 months <br />) | |
| Opened: | James Pate 10:21 Nov 23, 2016 |
| NRC Officer: | Jeff Herrera |
| Last Updated: | Nov 23, 2016 |
| 52391 - NRC Website | |
Qsa Global, Inc. with Agreement State | |
WEEKMONTHYEARENS 575922025-03-05T05:00:0005 March 2025 05:00:00
[Table view]Agreement State Leaking Sealed Source ENS 560302022-07-25T04:00:00025 July 2022 04:00:00 Agreement State Lost/Missing Category 2 Radioactive Material Shipment ENS 557952022-03-18T17:06:00018 March 2022 17:06:00 Agreement State Lost Package Containing Radioactive Material ENS 555472021-10-26T20:50:00026 October 2021 20:50:00 Agreement State Radiography Camera Delivered to Wrong Address ENS 551632021-03-31T14:44:00031 March 2021 14:44:00 Agreement State Sealed Source Missing in Transit ENS 551192021-03-01T19:00:0001 March 2021 19:00:00 Agreement State Category 2 Package Containing Seven Sealed Sources Lost in Transit ENS 551122021-02-23T17:00:00023 February 2021 17:00:00 Agreement State Lost Source ENS 532332018-02-28T15:30:00028 February 2018 15:30:00 Agreement State Agreement State Report - Package Containing Category 2 Sealed Sources Missing in Transit ENS 523912016-11-03T06:00:0003 November 2016 06:00:00 Agreement State Agreement State Report - Leaking Kr-85 Source During Transfer to Approved Shipping Container ENS 518252016-03-26T04:00:00026 March 2016 04:00:00 Agreement State Agreement State Report - Missing Shipment of Radioactive Materials ENS 514992015-10-26T05:00:00026 October 2015 05:00:00 Agreement State Nuclear Density Gauge Potentially Damaged During Shipment ENS 508202015-02-13T17:35:00013 February 2015 17:35:00 Agreement State Agreement State Report - Cat 1 Iridium-192 Shipment Lost/Found During Transit ENS 507352015-01-14T18:47:00014 January 2015 18:47:00 Agreement State Agreement State Report - Two Category 2 Iridium Sources Unaccounted for During Shipment ENS 504582014-08-06T04:00:0006 August 2014 04:00:00 Agreement State Agreement State Report - Manufacturing Defect Resulting in Equipment to Not Perform as Designed ENS 465792011-01-26T05:00:00026 January 2011 05:00:00 Agreement State Agreement State Report - Missing Radioactive Material Shipment ENS 464082010-11-08T05:00:0008 November 2010 05:00:00 Agreement State Agreement State Report - Radioactive Material Shipment Fails to Arrive ENS 444302008-08-20T20:41:00020 August 2008 20:41:00 Agreement State Massachusetts Agreement State Report - Radiation Greater than Ten Times Limit 2025-03-05T05:00:00 | |