ENS 51000
ENS Event | |
---|---|
02:45 Apr 22, 2015 | |
Title | Agreement State Report - Radiography Truck Accident Resulting in a Fatality |
Event Description | The following information was received by the State of Texas via email:
On April 21, 2015 at 2209 [CDT] hours, the Agency [Texas Department of State Health Services] was contacted by Andrews County Emergency Management (ACEM). They informed the Agency that an accident had occurred 12 miles south of Andrews, Texas, on highway 385, which involved a radiography truck. The Agency contacted ACEM chief who stated he was at the scene of a three vehicle accident which included a truck from Desert NDT. The driver was killed in the accident and the truck cab had separated from the frame. He stated the dark room had separated from the truck bed. He stated a person from the Andrews County WCS [Waste Control Specialist] was there and had performed a radiation survey and measured a dose rate of 15 millirem 10 feet from the truck. He stated the licensee had been contacted. He stated they had taken care of the survivors and had backed out of the area until the licensee's radiation safety officer arrived on the scene. He stated they had not seen the shipping papers, only the radiation symbol on the truck. I asked him to have the licensee contact the Agency as soon as they arrived on site. The licensee's (Desert NDT) RSO arrived at the scene at 2223 hours0.0257 days <br />0.618 hours <br />0.00368 weeks <br />8.458515e-4 months <br /> and contacted the Agency. He stated his priority was to locate the source. He agreed to call the Agency as soon as he had control of the source. At 2240, the RSO contacted the Agency and stated he had control of the source. The iridium source was inside a INC 100 radiography camera and the RSO believed the activity was between 20 and 26 curies. He stated the camera did not appear to be damaged. He stated the dark room had separated from the truck and split into two pieces. The camera was located still in its transport box in a section of the darkroom. He stated the dose rate on contact with the camera was 16 millirem an hour and 0.4 millirem at 1 foot. The dose rate at 1 meter was not distinguishable from background. He stated no individual at the scene would have received an exposure to radiation that would have exceeded any limits. The RSO stated he was taking the source back to the licensee's office for storage. The RSO stated they would send the exposure device to the manufacturer for inspection. Additional information will be provided as it is received in accordance with SA-300. Texas Incident: I-9305
The following information was received by the State of Texas via email: The licensee's corporate radiation safety officer contacted the Agency [Texas Department of State Health Services] and informed them that two radiographers were killed in this event. He stated the source activity was only 13 curies. He stated that local law enforcement in Andrews, Texas will not release any details of the accident until their investigation is completed. Additional information will be provided as it is received in accordance with SA-300. Notified the R4DO (Drake), IRD MOC (Gott) and the NMSS Events Notification via email. |
Where | |
---|---|
Desert Ndt Llc Abilene, Texas (NRC Region 4) | |
License number: | L06462 |
Organization: | Texas Dept Of State Health Services |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+-2.45 h-0.102 days <br />-0.0146 weeks <br />-0.00336 months <br />) | |
Opened: | Arthur Tucker 00:18 Apr 22, 2015 |
NRC Officer: | Vince Klco |
Last Updated: | Apr 22, 2015 |
51000 - NRC Website | |
Desert Ndt Llc with Agreement State | |
WEEKMONTHYEARENS 549892020-11-02T20:30:0002 November 2020 20:30:00
[Table view]Agreement State Possible Misconnect of Radiography Source ENS 543772019-11-06T06:00:0006 November 2019 06:00:00 Agreement State Texas Agreement State Report - Unable to Retract Radiography Source ENS 540932019-05-29T05:00:00029 May 2019 05:00:00 Agreement State Agreement State Report - Source Drive Cable Disconnected ENS 536792018-10-20T05:00:00020 October 2018 05:00:00 Agreement State Agreement State Report - Radiography Source Failure to Retract ENS 536412018-10-02T05:00:0002 October 2018 05:00:00 Agreement State Agreement State Report - Damaged Radiography Source ENS 535492018-08-11T05:00:00011 August 2018 05:00:00 Agreement State Agreement State Report - Unable to Retract Source ENS 534872018-07-03T05:00:0003 July 2018 05:00:00 Agreement State Agreement State Report - Source Disconnect ENS 534392018-05-31T05:00:00031 May 2018 05:00:00 Agreement State En Revision Imported Date 7/12/2018 ENS 528242017-06-23T05:00:00023 June 2017 05:00:00 Agreement State Agreement State Report - Possible Dose Exceeding Limits Received ENS 526712017-04-08T05:00:0008 April 2017 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Fails to Retract Properly ENS 520372016-06-22T05:00:00022 June 2016 05:00:00 Agreement State Agreement State Report - Radiography Camera Component Failure ENS 510002015-04-22T02:45:00022 April 2015 02:45:00 Agreement State Agreement State Report - Radiography Truck Accident Resulting in a Fatality ENS 506372014-11-24T06:00:00024 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 506342014-11-21T06:00:00021 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Failed to Operate Properly ENS 505522014-10-20T05:00:00020 October 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Retraction Failure ENS 505032014-08-01T05:00:0001 August 2014 05:00:00 Agreement State Agreement State Report - Locking Mechanism Failure ENS 499992014-04-04T05:00:0004 April 2014 05:00:00 Agreement State Agreement State Report - Camera Source Disconnect ENS 486932013-01-22T06:00:00022 January 2013 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect 2020-11-02T20:30:00 | |