ENS 53641
ENS Event | |
|---|---|
05:00 Oct 2, 2018 | |
| Title | Agreement State Report - Damaged Radiography Source |
| Event Description | The following was received via email from the State of Texas:
On October 3, 2018, the Agency [Texas Department of State Health Services] was notified by the licensee's radiation safety officer (RSO) that one of their radiography crews had reported they could not retract a 22 Curie Iridium-192 source into a SPEC 150 exposure device. The crew was working at a remote job site [in Carrizo Springs, TX]. The exposure device was sitting on a pipe rack. During an exposure (not the first one) the device fell off the pipe rack, hitting the guide tube, and crimping the tube to a point where the source could not be retracted back into the device. The crew contacted the RSO and a retrieval team was sent to the location. The source was positioned in the collimator and covered with bags of lead shot. The retrieval team was able to cut the protective coating off of the guide tube and, using a pair of pliers, reshape the guide tube until the source could be retracted to the fully locked position. No member of the general public received an exposure from this event. The highest dose received by an individual responding to this event was 40 millirem. Texas Incident: I-9616 |
| Where | |
|---|---|
| Desert Ndt Llc Abilene, Texas (NRC Region 4) | |
| License number: | L06462 |
| Organization: | Texas Dept Of State Health Services |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+34.18 h1.424 days <br />0.203 weeks <br />0.0468 months <br />) | |
| Opened: | Art Tucker 15:11 Oct 3, 2018 |
| NRC Officer: | Phil Natividad |
| Last Updated: | Oct 3, 2018 |
| 53641 - NRC Website | |
Desert Ndt Llc with Agreement State | |
WEEKMONTHYEARENS 549892020-11-02T20:30:0002 November 2020 20:30:00
[Table view]Agreement State Possible Misconnect of Radiography Source ENS 543772019-11-06T06:00:0006 November 2019 06:00:00 Agreement State Texas Agreement State Report - Unable to Retract Radiography Source ENS 540932019-05-29T05:00:00029 May 2019 05:00:00 Agreement State Agreement State Report - Source Drive Cable Disconnected ENS 536792018-10-20T05:00:00020 October 2018 05:00:00 Agreement State Agreement State Report - Radiography Source Failure to Retract ENS 536412018-10-02T05:00:0002 October 2018 05:00:00 Agreement State Agreement State Report - Damaged Radiography Source ENS 535492018-08-11T05:00:00011 August 2018 05:00:00 Agreement State Agreement State Report - Unable to Retract Source ENS 534872018-07-03T05:00:0003 July 2018 05:00:00 Agreement State Agreement State Report - Source Disconnect ENS 534392018-05-31T05:00:00031 May 2018 05:00:00 Agreement State En Revision Imported Date 7/12/2018 ENS 528242017-06-23T05:00:00023 June 2017 05:00:00 Agreement State Agreement State Report - Possible Dose Exceeding Limits Received ENS 526712017-04-08T05:00:0008 April 2017 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Fails to Retract Properly ENS 520372016-06-22T05:00:00022 June 2016 05:00:00 Agreement State Agreement State Report - Radiography Camera Component Failure ENS 510002015-04-22T02:45:00022 April 2015 02:45:00 Agreement State Agreement State Report - Radiography Truck Accident Resulting in a Fatality ENS 506372014-11-24T06:00:00024 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 506342014-11-21T06:00:00021 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Failed to Operate Properly ENS 505522014-10-20T05:00:00020 October 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Retraction Failure ENS 505032014-08-01T05:00:0001 August 2014 05:00:00 Agreement State Agreement State Report - Locking Mechanism Failure ENS 499992014-04-04T05:00:0004 April 2014 05:00:00 Agreement State Agreement State Report - Camera Source Disconnect ENS 486932013-01-22T06:00:00022 January 2013 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect 2020-11-02T20:30:00 | |