ENS 49999
ENS Event | |
|---|---|
05:00 Apr 4, 2014 | |
| Title | Agreement State Report - Camera Source Disconnect |
| Event Description | The following information was received by facsimile from the State of Texas:
On April 14, 2014, the Agency [Texas Department of State Health Services] was notified by the licensee's Corporate Radiation Safety Officer (CRSO) that one of their radiography crews had experienced source disconnect while using an INC IR 100 exposure device. The device contains a 70 curie iridium - 192 source. The CRSO stated the radiographers had completed a shot and noted the dose rates on the camera had not returned to normal after retracting the source. The radiographers increased the barriers around the exposure device and contacted their supervisor for assistance. The CRSO stated the source had been recovered by an individual listed on their license to retrieve sources. The CRSO stated he did not believe any individual received an exposure which exceeded any limits. The CRSO stated no member of the general public received any exposure. The CRSO stated he had just learned of the event and was beginning his investigation and would provide the Agency with additional information as it was obtained. This Agency will provide additional information as it is received in accordance with SA-300. Texas Incident: I-9178 |
| Where | |
|---|---|
| Desert Ndt Llc Abilene, Texas (NRC Region 4) | |
| License number: | 06462 |
| Organization: | Texas Department Of Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+11.62 h0.484 days <br />0.0692 weeks <br />0.0159 months <br />) | |
| Opened: | Art Tucker 16:37 Apr 4, 2014 |
| NRC Officer: | Vince Klco |
| Last Updated: | Apr 4, 2014 |
| 49999 - NRC Website | |
Desert Ndt Llc with Agreement State | |
WEEKMONTHYEARENS 549892020-11-02T20:30:0002 November 2020 20:30:00
[Table view]Agreement State Possible Misconnect of Radiography Source ENS 543772019-11-06T06:00:0006 November 2019 06:00:00 Agreement State Texas Agreement State Report - Unable to Retract Radiography Source ENS 540932019-05-29T05:00:00029 May 2019 05:00:00 Agreement State Agreement State Report - Source Drive Cable Disconnected ENS 536792018-10-20T05:00:00020 October 2018 05:00:00 Agreement State Agreement State Report - Radiography Source Failure to Retract ENS 536412018-10-02T05:00:0002 October 2018 05:00:00 Agreement State Agreement State Report - Damaged Radiography Source ENS 535492018-08-11T05:00:00011 August 2018 05:00:00 Agreement State Agreement State Report - Unable to Retract Source ENS 534872018-07-03T05:00:0003 July 2018 05:00:00 Agreement State Agreement State Report - Source Disconnect ENS 534392018-05-31T05:00:00031 May 2018 05:00:00 Agreement State En Revision Imported Date 7/12/2018 ENS 528242017-06-23T05:00:00023 June 2017 05:00:00 Agreement State Agreement State Report - Possible Dose Exceeding Limits Received ENS 526712017-04-08T05:00:0008 April 2017 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Fails to Retract Properly ENS 520372016-06-22T05:00:00022 June 2016 05:00:00 Agreement State Agreement State Report - Radiography Camera Component Failure ENS 510002015-04-22T02:45:00022 April 2015 02:45:00 Agreement State Agreement State Report - Radiography Truck Accident Resulting in a Fatality ENS 506372014-11-24T06:00:00024 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 506342014-11-21T06:00:00021 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Failed to Operate Properly ENS 505522014-10-20T05:00:00020 October 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Retraction Failure ENS 505032014-08-01T05:00:0001 August 2014 05:00:00 Agreement State Agreement State Report - Locking Mechanism Failure ENS 499992014-04-04T05:00:0004 April 2014 05:00:00 Agreement State Agreement State Report - Camera Source Disconnect ENS 486932013-01-22T06:00:00022 January 2013 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect 2020-11-02T20:30:00 | |