ENS 50552
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
05:00 Oct 20, 2014 | |
| Title | Agreement State Report - Radiography Camera Source Retraction Failure |
| Event Description | The following information was received via facsimile:
On October 20, 2014, the Agency [Texas Department of State Health Services] received notice that there had been a radiography source retraction failure at a temporary field site. A pipe had fallen from a stand onto the guide tube, causing a crimp. The source was retrieved by squeezing the crimp with pliers several times, allowing retraction. The individual performing the retrieval received 198 mR according to a pocket dosimeter. The camera was an INC IR-100 (sn 6832) with an Ir-192 source at 44 Ci (sn W644 ). Additional information will be supplied as it is received in accordance with SA-300. This event occurred at a field site in Encinal, Texas. Texas Incident #: I-9245 |
| Where | |
|---|---|
| Desert Ndt Llc Pharr, Texas (NRC Region 4) | |
| License number: | 06462 |
| Organization: | Texas Dept Of State Health Services |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+11.05 h0.46 days <br />0.0658 weeks <br />0.0151 months <br />) | |
| Opened: | Chris Moore 16:03 Oct 20, 2014 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Oct 20, 2014 |
| 50552 - NRC Website | |
Desert Ndt Llc with Agreement State | |
WEEKMONTHYEARENS 549892020-11-02T20:30:0002 November 2020 20:30:00
[Table view]Agreement State Possible Misconnect of Radiography Source ENS 543772019-11-06T06:00:0006 November 2019 06:00:00 Agreement State Texas Agreement State Report - Unable to Retract Radiography Source ENS 540932019-05-29T05:00:00029 May 2019 05:00:00 Agreement State Agreement State Report - Source Drive Cable Disconnected ENS 536792018-10-20T05:00:00020 October 2018 05:00:00 Agreement State Agreement State Report - Radiography Source Failure to Retract ENS 536412018-10-02T05:00:0002 October 2018 05:00:00 Agreement State Agreement State Report - Damaged Radiography Source ENS 535492018-08-11T05:00:00011 August 2018 05:00:00 Agreement State Agreement State Report - Unable to Retract Source ENS 534872018-07-03T05:00:0003 July 2018 05:00:00 Agreement State Agreement State Report - Source Disconnect ENS 534392018-05-31T05:00:00031 May 2018 05:00:00 Agreement State En Revision Imported Date 7/12/2018 ENS 528242017-06-23T05:00:00023 June 2017 05:00:00 Agreement State Agreement State Report - Possible Dose Exceeding Limits Received ENS 526712017-04-08T05:00:0008 April 2017 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Fails to Retract Properly ENS 520372016-06-22T05:00:00022 June 2016 05:00:00 Agreement State Agreement State Report - Radiography Camera Component Failure ENS 510002015-04-22T02:45:00022 April 2015 02:45:00 Agreement State Agreement State Report - Radiography Truck Accident Resulting in a Fatality ENS 506372014-11-24T06:00:00024 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 506342014-11-21T06:00:00021 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Failed to Operate Properly ENS 505522014-10-20T05:00:00020 October 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Retraction Failure ENS 505032014-08-01T05:00:0001 August 2014 05:00:00 Agreement State Agreement State Report - Locking Mechanism Failure ENS 499992014-04-04T05:00:0004 April 2014 05:00:00 Agreement State Agreement State Report - Camera Source Disconnect ENS 486932013-01-22T06:00:00022 January 2013 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect 2020-11-02T20:30:00 | |