ENS 52037
ENS Event | |
---|---|
05:00 Jun 22, 2016 | |
Title | Agreement State Report - Radiography Camera Component Failure |
Event Description | The following information was received from the State of Texas by email:
On June 23, 2016, the licensee notified the Agency [Texas Department of State Health Services] that a radiography camera had failed to lock in position after retracting the source. The ball stop moved about 3/16 of an inch causing the camera to not lock in position after the source was retracted into position. The licensee's radiation safety officer (RSO) obtained the following information about this component failure. The camera was a delta 880 source serial number S7340 at an activity of 52.6 curies. No overexposures were reported to the RSO. An investigation into this event is being conducted by the RSO. The camera has been secured and is located at one of the licensee's sites. Updates will be provided as obtained in accordance with SA300. Texas Incident: I-9415 |
Where | |
---|---|
Desert Ndt Llc Abilene, Texas (NRC Region 4) | |
License number: | 06462 |
Organization: | Texas Dept Of State Health Services |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+36.22 h1.509 days <br />0.216 weeks <br />0.0496 months <br />) | |
Opened: | Irene Casares 17:13 Jun 23, 2016 |
NRC Officer: | Vince Klco |
Last Updated: | Jun 23, 2016 |
52037 - NRC Website | |
Desert Ndt Llc with Agreement State | |
WEEKMONTHYEARENS 549892020-11-02T20:30:0002 November 2020 20:30:00
[Table view]Agreement State Possible Misconnect of Radiography Source ENS 543772019-11-06T06:00:0006 November 2019 06:00:00 Agreement State Texas Agreement State Report - Unable to Retract Radiography Source ENS 540932019-05-29T05:00:00029 May 2019 05:00:00 Agreement State Agreement State Report - Source Drive Cable Disconnected ENS 536792018-10-20T05:00:00020 October 2018 05:00:00 Agreement State Agreement State Report - Radiography Source Failure to Retract ENS 536412018-10-02T05:00:0002 October 2018 05:00:00 Agreement State Agreement State Report - Damaged Radiography Source ENS 535492018-08-11T05:00:00011 August 2018 05:00:00 Agreement State Agreement State Report - Unable to Retract Source ENS 534872018-07-03T05:00:0003 July 2018 05:00:00 Agreement State Agreement State Report - Source Disconnect ENS 534392018-05-31T05:00:00031 May 2018 05:00:00 Agreement State En Revision Imported Date 7/12/2018 ENS 528242017-06-23T05:00:00023 June 2017 05:00:00 Agreement State Agreement State Report - Possible Dose Exceeding Limits Received ENS 526712017-04-08T05:00:0008 April 2017 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Fails to Retract Properly ENS 520372016-06-22T05:00:00022 June 2016 05:00:00 Agreement State Agreement State Report - Radiography Camera Component Failure ENS 510002015-04-22T02:45:00022 April 2015 02:45:00 Agreement State Agreement State Report - Radiography Truck Accident Resulting in a Fatality ENS 506372014-11-24T06:00:00024 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 506342014-11-21T06:00:00021 November 2014 06:00:00 Agreement State Agreement State Report - Radiography Camera Failed to Operate Properly ENS 505522014-10-20T05:00:00020 October 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Retraction Failure ENS 505032014-08-01T05:00:0001 August 2014 05:00:00 Agreement State Agreement State Report - Locking Mechanism Failure ENS 499992014-04-04T05:00:0004 April 2014 05:00:00 Agreement State Agreement State Report - Camera Source Disconnect ENS 486932013-01-22T06:00:00022 January 2013 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect 2020-11-02T20:30:00 | |