Title | Agreement State Report - Radiography Camera Source Disconnect |
Event Description | The following information was received from the State of Ohio via email:
Licensee contacted BROP [Bureau of Radiation Protection] at approximately 2:30 PM on 5/6/14 to report that a radiography crew experienced a source disconnect during radiography operations earlier in the day. After completing the 3rd shot of the day a radiographer attempted to crank the source back into the camera. The drive cable appeared to crank back in but reading on the survey meter indicated that the source was still outside the camera, apparently in the area of the collimator. Licensee personnel attempted to crank the cable in and out several times in an attempt to retract the source, but were unsuccessful. The area was secured and monitored by licensee personnel pending further retrieval efforts. The corporate RSO was contacted, who dispatch two trained source retrieval personnel to the location. During evaluation it was determined that the drive cable had broken near the male connector. Licensee personnel were able to unlock the camera, feed the broken drive cable through the camera, and retrieve the source into the shielded position. Retrieval was accomplished at approximately 6:30 PM that evening. A new drive cable was connected to the camera and the radiographers were able to continue operating the camera with the new drive cable without incident. The two licensee retrieval personnel recorded doses of 20 mRem and 40 mRem on their pocket dosimeters. The licensee is having the broken drive cable returned to their corporate office for examination to determine the cause of the break. Licensee is preparing a written report on this incident. The Radiography Camera involved is a QSA Model 880D, Serial number D8378 containing 46.1 Curie Ir-192 source. The sealed source is model number A424-9, serial number 12727C. The incident occurred at the Kensington, OH site. State of Ohio Reference No.: 2014-010 Corrective actions included obtaining a new cable. Repairs were made without an engineering change to the system. State of Ohio submitted the NMED Item Number: OH140006 on 05/07/14. |
Where | |
---|---|
Team Industrial Services Utica, Ohio (NRC Region 3) | |
License number: | 03320 99 0000 |
Organization: | Ohio Bureau Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+152.88 h6.37 days <br />0.91 weeks <br />0.209 months <br />) | |
Opened: | Stephen James 12:53 May 12, 2014 |
NRC Officer: | Steve Sandin |
Last Updated: | May 12, 2014 |
50107 - NRC Website | |
Team Industrial Services with Agreement State | |
WEEKMONTHYEARENS 523492016-11-03T04:00:0003 November 2016 04:00:00
[Table view]Agreement State Agreement State Report - Failure of Source to Retract to Safe Position ENS 511802015-06-25T13:30:00025 June 2015 13:30:00 Agreement State Agreement State Report - Lost Radiography Camera During Transit ENS 508442015-02-23T06:00:00023 February 2015 06:00:00 Agreement State Agreement State Report - Damaged Guide Tube on Radiography Camera Preventing Source Retraction ENS 505722014-10-28T04:00:00028 October 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Can Not Be Retracted ENS 501072014-05-06T04:00:0006 May 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 500422014-04-16T05:00:00016 April 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Failure of Source to Retract to Safe Position ENS 484172012-10-16T05:00:00016 October 2012 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 480252012-05-22T07:00:00022 May 2012 07:00:00 Agreement State Agreement State Report - Camera Source Fails to Retract ENS 467502011-04-12T14:35:00012 April 2011 14:35:00 Agreement State Agreement State Report - Fire in Portable Darkroom ENS 464302010-11-21T18:00:00021 November 2010 18:00:00 Agreement State Agreement State Report - Source Disconnect and Retrieval ENS 463162010-10-03T05:00:0003 October 2010 05:00:00 Agreement State Agreement State - Radiography Source Failed to Retract ENS 458182010-04-07T05:00:0007 April 2010 05:00:00 Agreement State Agreement State - Radiography Truck Involved in Auto Accident ENS 453852009-09-25T19:00:00025 September 2009 19:00:00 Agreement State Agreement State Report - Source Disconnected from Radiography Camera ENS 444932008-09-16T05:00:00016 September 2008 05:00:00 Agreement State Radiography Camera Source Failed to Return to Safe Position ENS 443692008-07-25T05:00:00025 July 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfunction ENS 441452008-04-17T05:00:00017 April 2008 05:00:00 Agreement State Radiography Camera Malfunction ENS 440192008-02-28T06:00:00028 February 2008 06:00:00 Agreement State Agreement State Report - Overexposed Personnel Monitoring Badge ENS 435042007-07-18T15:00:00018 July 2007 15:00:00 Agreement State Agreement State Report - Defective Radiography Camera ENS 426192006-06-02T14:30:0002 June 2006 14:30:00 Agreement State Agreement State Report - Personnel Overexposure 2016-11-03T04:00:00 | |