ENS 50572
ENS Event | |
|---|---|
04:00 Oct 28, 2014 | |
| Title | Agreement State Report - Radiography Camera Source Can Not Be Retracted |
| Event Description | The following information was received from the Commonwealth of Pennsylvania via email:
The Department's [PA Department of Radiation Protection] Southwest Office informed the Central Office of this event on October 28, 2014. This event is reportable to the Department within 24-hours per 10 CFR 30.50(b)(2), and within 30 days as per 10 CFR 34.101(a)2. While radiographing a pipe in the field, a crew had an incident where the camera fell and crimped the guide tube, and the source could not be retracted. The area was immediately secured after the event, and recovery operation initiated. The recovery was completed within two hours. Using long handled pliers under lead sheets, the licensee was able to un-crimp the guide tube and retract the source back into the camera. The readings with the lead sheets in place were in the range of 10 to 15 milli-roentgen per hour (mR/h). Electronic dosimetry readings of those involved with the recovery were provided to the Department [Radiation Protection], with no whole body results above 40 mR. Camera Information: Serial#: D12920 Source Information: Serial #: 11088G Isotope: lr-192 Activity: 99 Ci CAUSE OF THE EVENT: The camera was not tied down to the pipe, it slid off the supporting structure, fell, and crimped the guide tube. ACTIONS: The licensee was able to un-crimp the guide tube and retract the source back into the camera. The Department plans a reactive inspection. PA Event Report ID No.: PA140022 |
| Where | |
|---|---|
| Team Industrial Services Pittsburg, Pennsylvania (NRC Region 1) | |
| License number: | PA-1176 |
| Organization: | Pa Bureau Of Radiation Protection |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+32.62 h1.359 days <br />0.194 weeks <br />0.0447 months <br />) | |
| Opened: | Joseph Melnic 12:37 Oct 29, 2014 |
| NRC Officer: | Jeff Rotton |
| Last Updated: | Oct 29, 2014 |
| 50572 - NRC Website | |
Team Industrial Services with Agreement State | |
WEEKMONTHYEARENS 580142025-10-29T06:00:00029 October 2025 06:00:00
[Table view]Agreement State Stuck Source ENS 579622025-10-01T19:15:0001 October 2025 19:15:00 Agreement State Stuck Source ENS 523492016-11-03T04:00:0003 November 2016 04:00:00 Agreement State Agreement State Report - Failure of Source to Retract to Safe Position ENS 511802015-06-25T13:30:00025 June 2015 13:30:00 Agreement State Agreement State Report - Lost Radiography Camera During Transit ENS 508442015-02-23T06:00:00023 February 2015 06:00:00 Agreement State Agreement State Report - Damaged Guide Tube on Radiography Camera Preventing Source Retraction ENS 505722014-10-28T04:00:00028 October 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Can Not Be Retracted ENS 501072014-05-06T04:00:0006 May 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 500422014-04-16T05:00:00016 April 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Failure of Source to Retract to Safe Position ENS 484172012-10-16T05:00:00016 October 2012 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 480252012-05-22T07:00:00022 May 2012 07:00:00 Agreement State Agreement State Report - Camera Source Fails to Retract ENS 467502011-04-12T14:35:00012 April 2011 14:35:00 Agreement State Agreement State Report - Fire in Portable Darkroom ENS 464302010-11-21T18:00:00021 November 2010 18:00:00 Agreement State Agreement State Report - Source Disconnect and Retrieval ENS 463162010-10-03T05:00:0003 October 2010 05:00:00 Agreement State Agreement State - Radiography Source Failed to Retract ENS 458182010-04-07T05:00:0007 April 2010 05:00:00 Agreement State Agreement State - Radiography Truck Involved in Auto Accident ENS 453852009-09-25T19:00:00025 September 2009 19:00:00 Agreement State Agreement State Report - Source Disconnected from Radiography Camera ENS 444932008-09-16T05:00:00016 September 2008 05:00:00 Agreement State Radiography Camera Source Failed to Return to Safe Position ENS 443692008-07-25T05:00:00025 July 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfunction ENS 441452008-04-17T05:00:00017 April 2008 05:00:00 Agreement State Radiography Camera Malfunction ENS 440192008-02-28T06:00:00028 February 2008 06:00:00 Agreement State Agreement State Report - Overexposed Personnel Monitoring Badge ENS 435042007-07-18T15:00:00018 July 2007 15:00:00 Agreement State Agreement State Report - Defective Radiography Camera ENS 426192006-06-02T14:30:0002 June 2006 14:30:00 Agreement State Agreement State Report - Personnel Overexposure 2025-10-29T06:00:00 | |