ENS 46430
ENS Event | |
|---|---|
18:00 Nov 21, 2010 | |
| Title | Agreement State Report - Source Disconnect and Retrieval |
| Event Description | The following information was provided by the State of Texas via email:
On November 22, 2010, the [Texas Department of Health Services] Agency received notification from the licensee that it had experienced a source disconnect yesterday, November 21, 2010 at approximately 1200 CST. The licensee stated that a two person radiography crew was working at a refinery near Alvin, Texas when they experienced a source disconnect. The radiographers were using a QSA Global device (Model: 660-B) that housed a 67 curie, Selenium (Se) - 75 source. According to the licensee, the radiographers had made 24 exposures and on the 25th exposure, the source disconnected from the drive cable. The radiographers were able to crank the cable back into the camera, but the source remained out. The radiographers contacted their Site Radiation Safety Officer (SRSO). The SRSO, who is authorized to retrieve sources, traveled to the site and returned the source to the camera at approximately 1700 CST. The radiographers at the site waited for the SRSO to arrive while verifying the 2 millirem per hour boundary, and keeping constant security on the radioactive material. According to the licensee, the highest exposure measured by the radiographers' pocket dosimeters was that of the SRSO, whose dose was measured to be 45 millirem for the event. The licensee stated that they were unsure why the source disconnected from the drive cable. However, the licensee has contacted the manufacturer, and will send the entire set-up (camera, guide tube, drive cable, etc) to the manufacturer for inspection and repair. TX: I-8798 |
| Where | |
|---|---|
| Team Industrial Services Alvin, Texas (NRC Region 4) | |
| License number: | 00087 |
| Organization: | Texas Department Of Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+17.63 h0.735 days <br />0.105 weeks <br />0.0241 months <br />) | |
| Opened: | Annie Backhaus 11:38 Nov 22, 2010 |
| NRC Officer: | Joe O'Hara |
| Last Updated: | Nov 22, 2010 |
| 46430 - NRC Website | |
Team Industrial Services with Agreement State | |
WEEKMONTHYEARENS 580142025-10-29T06:00:00029 October 2025 06:00:00
[Table view]Agreement State Stuck Source ENS 579622025-10-01T19:15:0001 October 2025 19:15:00 Agreement State Stuck Source ENS 523492016-11-03T04:00:0003 November 2016 04:00:00 Agreement State Agreement State Report - Failure of Source to Retract to Safe Position ENS 511802015-06-25T13:30:00025 June 2015 13:30:00 Agreement State Agreement State Report - Lost Radiography Camera During Transit ENS 508442015-02-23T06:00:00023 February 2015 06:00:00 Agreement State Agreement State Report - Damaged Guide Tube on Radiography Camera Preventing Source Retraction ENS 505722014-10-28T04:00:00028 October 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Can Not Be Retracted ENS 501072014-05-06T04:00:0006 May 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 500422014-04-16T05:00:00016 April 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Failure of Source to Retract to Safe Position ENS 484172012-10-16T05:00:00016 October 2012 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 480252012-05-22T07:00:00022 May 2012 07:00:00 Agreement State Agreement State Report - Camera Source Fails to Retract ENS 467502011-04-12T14:35:00012 April 2011 14:35:00 Agreement State Agreement State Report - Fire in Portable Darkroom ENS 464302010-11-21T18:00:00021 November 2010 18:00:00 Agreement State Agreement State Report - Source Disconnect and Retrieval ENS 463162010-10-03T05:00:0003 October 2010 05:00:00 Agreement State Agreement State - Radiography Source Failed to Retract ENS 458182010-04-07T05:00:0007 April 2010 05:00:00 Agreement State Agreement State - Radiography Truck Involved in Auto Accident ENS 453852009-09-25T19:00:00025 September 2009 19:00:00 Agreement State Agreement State Report - Source Disconnected from Radiography Camera ENS 444932008-09-16T05:00:00016 September 2008 05:00:00 Agreement State Radiography Camera Source Failed to Return to Safe Position ENS 443692008-07-25T05:00:00025 July 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfunction ENS 441452008-04-17T05:00:00017 April 2008 05:00:00 Agreement State Radiography Camera Malfunction ENS 440192008-02-28T06:00:00028 February 2008 06:00:00 Agreement State Agreement State Report - Overexposed Personnel Monitoring Badge ENS 435042007-07-18T15:00:00018 July 2007 15:00:00 Agreement State Agreement State Report - Defective Radiography Camera ENS 426192006-06-02T14:30:0002 June 2006 14:30:00 Agreement State Agreement State Report - Personnel Overexposure 2025-10-29T06:00:00 | |