ENS 44145
ENS Event | |
---|---|
05:00 Apr 17, 2008 | |
Title | Radiography Camera Malfunction |
Event Description | This "incident occurred on April 15, 2008 at about 8:20 PM at a new [non-nuclear] power plant under construction. Team Industrial Services was performing industrial radiography on Unit 1. The radiography was being performed on elevation 807 on a header approximately 4 foot off of the roof of the boiler.
According to statements from the crew, they had exposed the source on their first shot of the pipe weld, and approximately 15 seconds into the shot they heard what they thought was the guide tube and collimator faillng off the pipe to the roof of the boiler. They then went to retract the source back into the exposure device and encountered an obstruction preventing the source from being retracted into a secured position in the exposure device. They attempted [to retract the source] three times with no success. The industrial radiographer contacted the facility radiation safety officer and advised him that he had a source he could not retract back into the exposure device. The industrial radiographer extended the radiation safety boundaries above and below the area. The Radiation Safety Officer (RSO) advised [the radiographer] that he was on his way to the site. The RSO arrived at the site at approximately 9:00 PM. At this time an initial assessment was made and a decision was made to bring in two more trained technicians to assist with boundary control and retrieval of the sealed source. After arrival of the extra technicians, a plan for retrieval was discussed with all technicians, including the Corporate Radiation Safety Officer. The industrial radiographer stated that his pocket dosimeter had gone 'off scale.' This means that he could have received a dose of at least 200 millirems of radiation. At this time he was advised that he would not be assisting with the retrieval but he continued to assist with boundary control. The licensee has estimated that the industrial radiographer received 630 mR. At approximately 11:35 PM, the shielding of the source and attempt to repair the guide tube commenced. Four lead shot bags were placed over the end of the guide tube where the sealed source was known to be. The radiation levels were reduced to 15 millirems per hour at five feet from the source under the lead shot bags. The RSO then approached the guide tube with a pair of pliers, located the distortion in the guide tube and rounded it with the pliers. He then returned to the crank assembly and retracted the source successfully back into the exposure device. The RSO is estimated to have received 32 mR from conducting the repair. A determination was made that there was not an equipment failure, it was a result of the guide tube falling from the pipe to the roof of the boiler that damaged the guide tube resulting in the obstruction. Boundaries were maintained throughout the incident to ensure that at no time any member of the general public could enter the incident area. DHFS plans to investigate this incident on the next inspection (to be conducted in the near future). |
Where | |
---|---|
Team Industrial Services Milwaukee, Wisconsin (NRC Region 3) | |
License number: | 079-2005-01 |
Organization: | Wisconsin Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+12.45 h0.519 days <br />0.0741 weeks <br />0.0171 months <br />) | |
Opened: | Cheryl K. Rogers 17:27 Apr 17, 2008 |
NRC Officer: | Pete Snyder |
Last Updated: | Apr 17, 2008 |
44145 - NRC Website | |
Team Industrial Services with Agreement State | |
WEEKMONTHYEARENS 523492016-11-03T04:00:0003 November 2016 04:00:00
[Table view]Agreement State Agreement State Report - Failure of Source to Retract to Safe Position ENS 511802015-06-25T13:30:00025 June 2015 13:30:00 Agreement State Agreement State Report - Lost Radiography Camera During Transit ENS 508442015-02-23T06:00:00023 February 2015 06:00:00 Agreement State Agreement State Report - Damaged Guide Tube on Radiography Camera Preventing Source Retraction ENS 505722014-10-28T04:00:00028 October 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Can Not Be Retracted ENS 501072014-05-06T04:00:0006 May 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 500422014-04-16T05:00:00016 April 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Failure of Source to Retract to Safe Position ENS 484172012-10-16T05:00:00016 October 2012 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 480252012-05-22T07:00:00022 May 2012 07:00:00 Agreement State Agreement State Report - Camera Source Fails to Retract ENS 467502011-04-12T14:35:00012 April 2011 14:35:00 Agreement State Agreement State Report - Fire in Portable Darkroom ENS 464302010-11-21T18:00:00021 November 2010 18:00:00 Agreement State Agreement State Report - Source Disconnect and Retrieval ENS 463162010-10-03T05:00:0003 October 2010 05:00:00 Agreement State Agreement State - Radiography Source Failed to Retract ENS 458182010-04-07T05:00:0007 April 2010 05:00:00 Agreement State Agreement State - Radiography Truck Involved in Auto Accident ENS 453852009-09-25T19:00:00025 September 2009 19:00:00 Agreement State Agreement State Report - Source Disconnected from Radiography Camera ENS 444932008-09-16T05:00:00016 September 2008 05:00:00 Agreement State Radiography Camera Source Failed to Return to Safe Position ENS 443692008-07-25T05:00:00025 July 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfunction ENS 441452008-04-17T05:00:00017 April 2008 05:00:00 Agreement State Radiography Camera Malfunction ENS 440192008-02-28T06:00:00028 February 2008 06:00:00 Agreement State Agreement State Report - Overexposed Personnel Monitoring Badge ENS 435042007-07-18T15:00:00018 July 2007 15:00:00 Agreement State Agreement State Report - Defective Radiography Camera ENS 426192006-06-02T14:30:0002 June 2006 14:30:00 Agreement State Agreement State Report - Personnel Overexposure 2016-11-03T04:00:00 | |