05:00 Apr 7, 2010 | |
| Title | Agreement State - Radiography Truck Involved in Auto Accident |
| Event Description | On April 7, 2010 at approximately 1430 CST the Incident Investigation Program was notified by the licensee's Radiation Safety Officer (RSO) that one of the licensee's trucks carrying a camera with a 24 curie Iridium (Ir) 192 source had been involved in a car accident around 1300 CST that same day. The RSO stated that the radiography truck had collided head on with a tractor-trailer on a highway approximately 8-10 miles east of Kosse, Texas. One of the radiographers was fatally wounded and the other was rushed to the hospital. Consequently, no one was able to perform a survey to verify the source was intact in the camera as well as secure the camera. The RSO stated that the Robinson County Emergency Management Coordinator was on the scene along with police and fire personnel, as well as Texas Department of Transportation. The RSO stated that none of the emergency personnel responding were equipped with a radiation survey meter to verify the source locale. The RSO stated that the Site Radiation Safety Officer was en route to the scene to perform a survey and retrieve the camera, but he was almost two hours away. The Emergency Management Coordinator had cordoned off the area around the radiography camera. I contacted an Agency investigator who was near the area performing field work, and he agreed to go by the location and perform a survey because he could be there within 45 minutes. At approximately 1630, the investigator arrived on the scene and performed his survey. The investigator stated that it appeared the source was still housed in the camera and that the highest dose rate was 2.2 millirems/hour near the camera. The site RSO arrived on the scene, and the investigator briefed him on the survey. The information was passed to the RSO and he agreed to submit a report to the Agency.
Texas Incident #: I-8728 |
| Where | |
|---|---|
| Team Industrial Services Alvin, Texas (NRC Region 4) | |
| License number: | 00087 |
| Organization: | Texas Department Of Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+12.77 h0.532 days <br />0.076 weeks <br />0.0175 months <br />) | |
| Opened: | Annie Backhaus 17:46 Apr 7, 2010 |
| NRC Officer: | Charles Teal |
| Last Updated: | Apr 7, 2010 |
| 45818 - NRC Website | |
Team Industrial Services with Agreement State | |
WEEKMONTHYEARENS 580142025-10-29T06:00:00029 October 2025 06:00:00
[Table view]Agreement State Stuck Source ENS 579622025-10-01T19:15:0001 October 2025 19:15:00 Agreement State Stuck Source ENS 523492016-11-03T04:00:0003 November 2016 04:00:00 Agreement State Agreement State Report - Failure of Source to Retract to Safe Position ENS 511802015-06-25T13:30:00025 June 2015 13:30:00 Agreement State Agreement State Report - Lost Radiography Camera During Transit ENS 508442015-02-23T06:00:00023 February 2015 06:00:00 Agreement State Agreement State Report - Damaged Guide Tube on Radiography Camera Preventing Source Retraction ENS 505722014-10-28T04:00:00028 October 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Can Not Be Retracted ENS 501072014-05-06T04:00:0006 May 2014 04:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 500422014-04-16T05:00:00016 April 2014 05:00:00 Agreement State Agreement State Report - Radiography Camera Failure of Source to Retract to Safe Position ENS 484172012-10-16T05:00:00016 October 2012 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 480252012-05-22T07:00:00022 May 2012 07:00:00 Agreement State Agreement State Report - Camera Source Fails to Retract ENS 467502011-04-12T14:35:00012 April 2011 14:35:00 Agreement State Agreement State Report - Fire in Portable Darkroom ENS 464302010-11-21T18:00:00021 November 2010 18:00:00 Agreement State Agreement State Report - Source Disconnect and Retrieval ENS 463162010-10-03T05:00:0003 October 2010 05:00:00 Agreement State Agreement State - Radiography Source Failed to Retract ENS 458182010-04-07T05:00:0007 April 2010 05:00:00 Agreement State Agreement State - Radiography Truck Involved in Auto Accident ENS 453852009-09-25T19:00:00025 September 2009 19:00:00 Agreement State Agreement State Report - Source Disconnected from Radiography Camera ENS 444932008-09-16T05:00:00016 September 2008 05:00:00 Agreement State Radiography Camera Source Failed to Return to Safe Position ENS 443692008-07-25T05:00:00025 July 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfunction ENS 441452008-04-17T05:00:00017 April 2008 05:00:00 Agreement State Radiography Camera Malfunction ENS 440192008-02-28T06:00:00028 February 2008 06:00:00 Agreement State Agreement State Report - Overexposed Personnel Monitoring Badge ENS 435042007-07-18T15:00:00018 July 2007 15:00:00 Agreement State Agreement State Report - Defective Radiography Camera ENS 426192006-06-02T14:30:0002 June 2006 14:30:00 Agreement State Agreement State Report - Personnel Overexposure 2025-10-29T06:00:00 | |