| Title | Notification of Unusual Event Due to Primary System Leakage Greater than 10 Gpm |
| Event Description | The Licensee declared an Unusual Event for Palisades Unit 1 on 09/16/2011 at 1450 EDT based on EAL SU 8.1, RCS (Reactor Coolant System) leakage exceeding 10 gallons per minute (gpm). The licensee was monitoring an increase in RCS leakage, and at a rate of 3.5 gpm entered their off normal procedure and began shutting down the plant. Technical Specification requires the plant to be in Mode 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Leakage increased to greater than 10 gpm, and at 1454 EDT the reactor was manually tripped from 79% power. All control rods fully inserted, and the shutdown was described by the licensee as uncomplicated. Unit 1 is stable in Mode 3.
No safety injection was required since two charging pumps (B&C) were able to keep up with RCS leakage estimated to be between 14 and 15 gpm. Pressurizer level was restored to 43% and rising. RCS pressure was greater than 2000 psi and RCS temperature was being maintained at no load Tave of 535F on the turbine bypass valves. There is no indication of any primary-to-secondary leakage and all equipment is available except for charging pump 'A', which was tagged out of service for planned maintenance. An entry into containment had been made and the licensee had identified the source of the RCS leakage as being in the vicinity of the 'A' pressurizer spray control valve #1057. This was based on a steam plume seen from below the pressurizer looking up through grating towards this valve. The licensee has notified the NRC Resident Inspector.
At 1934 EDT the licensee terminated from their Unusual Event due to EAL SU 8.1. The plant is still in Mode 3 with a leak rate of 0.324 gpm..The licensee has confirmed that the leak is a result of the packing gland backing out of pressurizer spray valve #1057. The licensee has notified the NRC Resident Inspector. The R3DO (Bloomer) was notified. Notified FEMA (Eiscoe) and DHS (Flinter). |
| Where | |
|---|---|
| Palisades Michigan (NRC Region 3) | |
| Reporting | |
| Emergency class: | Unusual Event |
| 10 CFR 50.72(a) (1) (i), Emergency Class Declaration | |
| Time - Person (Reporting Time:+-3.77 h-0.157 days <br />-0.0224 weeks <br />-0.00516 months <br />) | |
| Opened: | Paul Adams 15:04 Sep 16, 2011 |
| NRC Officer: | John Knoke |
| Last Updated: | Sep 16, 2011 |
| 47271 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | Yes, Manual Scram |
| Before | Power Operation (79 %) |
| After | Hot Standby (0 %) |
WEEKMONTHYEARENS 510332015-05-02T16:23:0002 May 2015 16:23:00
[Table view]10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Seismic Activity Felt on Site ENS 472712011-09-16T18:50:00016 September 2011 18:50:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event Due to Primary System Leakage Greater than 10 Gpm ENS 471872011-08-23T18:52:00023 August 2011 18:52:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of an Unusual Event Due to a Seismic Event ENS 465242011-01-08T18:03:0008 January 2011 18:03:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Catastrophic Failure of Non-Safety Related Bus Breaker ENS 441482008-04-18T10:03:00018 April 2008 10:03:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Due to Seismic Activity ENS 416812005-05-09T23:46:0009 May 2005 23:46:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared 2015-05-02T16:23:00 | |