ENS Event | |
|---|---|
23:46 May 9, 2005 | |
| Title | Unusual Event Declared |
| Event Description | Emergency Category: Primary Coolant System Integrity
Appears leak has been isolated. The plant was performing a SI (Safety Injection) accumulator bottle sampling test. At the conclusion of the test, a valve failed to close which caused excessive pressure in a line. When the pressure source was isolated, thermal expansion occurred which pushed some fluid through the Primary Coolant System check valves into the primary coolant system. When the system was depressurized to relieve the pressure, the primary coolant check valve failed to reseat. As a result, approximately 90 gals of primary coolant back flowed through the primary check valve over a two minute period. The leakage was stopped when the line was isolated remotely from the control room. The plant is still in the unusual event. The exit criteria is a tech spec leak rate calculation to verify that primary coolant leakage is less than the tech spec allowed value which will take approximately three hours to complete. The licensee will be notifying the NRC Resident Inspector.
At 00:11 EDT on 05/10/05 the licensee terminated their Unusual Event for Primary Coolant System integrity. The present leak rate is 0.018 gal/min, which is within the allowable Technical Specification limit of <1 gal/min for unidentified primary coolant leakage. There is an LCO (72 hrs) for the primary coolant system check valve that improperly reseated (CK-ES-3131). The licensee notified the NRC Resident Inspector. Notified R3DO (Riemer), NRR EO (Gillespie), IRD Manager (McGinty), DHS (A. Akers) and FEMA (K. Biscoe). |
| Where | |
|---|---|
| Palisades Michigan (NRC Region 3) | |
| Reporting | |
| Emergency class: | Unusual Event |
| 10 CFR 50.72(a) (1) (i), Emergency Class Declaration | |
| Time - Person (Reporting Time:+-3.72 h-0.155 days <br />-0.0221 weeks <br />-0.0051 months <br />) | |
| Opened: | Floyd Lawrence 20:03 May 9, 2005 |
| NRC Officer: | Howie Crouch |
| Last Updated: | May 10, 2005 |
| 41681 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 510332015-05-02T16:23:0002 May 2015 16:23:00
[Table view]10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Seismic Activity Felt on Site ENS 472712011-09-16T18:50:00016 September 2011 18:50:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event Due to Primary System Leakage Greater than 10 Gpm ENS 471872011-08-23T18:52:00023 August 2011 18:52:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of an Unusual Event Due to a Seismic Event ENS 465242011-01-08T18:03:0008 January 2011 18:03:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Catastrophic Failure of Non-Safety Related Bus Breaker ENS 441482008-04-18T10:03:00018 April 2008 10:03:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Due to Seismic Activity ENS 416812005-05-09T23:46:0009 May 2005 23:46:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared 2015-05-02T16:23:00 | |