ENS 42611
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
14:23 May 30, 2006 | |
| Title | |
| Event Description | Control Room Emergency Filtration System (CREFS) was declared Inoperable at 0923 on 5/30/2006 per TS 5.5.10.c 'Ventilation Filter Testing Program'. Laboratory testing results of a sample of the charcoal adsorber taken on 5/2/2006 did not meet the methyl iodide penetration percentage acceptance criteria of less than or equal to 1.0%. This condition is covered by TS 3.7.9 and both Unit 1 and Unit 2 entered Condition A, 'CREFS Inoperable' with a Required Action of 'Restore CREFS to OPERABLE status' with a Completion Time of 7 Days.
CREFS is a single train system. Based on the guidance in NUREG-1022 for single train systems that perform safety functions, this condition was determined to be reportable under 10 CFR 50.72(b)(3)(v), 'Event or Condition That Could Have Prevented Fulfillment of a Safety Function'. Technical Specifications allow this system to be inoperable for a period of seven days. This condition was not reported within the 8 Hour Non-Emergency reporting requirements. The charcoal has been replaced and the licensee estimates testing at approximately 17:00. The licensee notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Point Beach Wisconsin (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| Time - Person (Reporting Time:+23.87 h0.995 days <br />0.142 weeks <br />0.0327 months <br />) | |
| Opened: | Dean Raasch 14:15 May 31, 2006 |
| NRC Officer: | Mark Abramovitz |
| Last Updated: | May 31, 2006 |
| 42611 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |