| Title | Failure to Ensure Mitigating System Availability and Reliability During Weather Conditions that Could Promote Frazil Ice at the LSH |
| Description | The inspectors identified a finding of very low safety significance when licensee personnel failed to ensure that the LSH trash rake would be capable of clearing ice buildup on the trash rake bars. Specifically, the licensee failed to ensure that the trash rake system was functional prior to the onset of weather conditions that could promote frazil ice production and after a repair following a trash rake failure during those conditions. The licensee entered this issue into their CAP as IR 1613767, LSH Trash Rake Will Not Traverse on Rails. The licensee corrected this issue by utilizing a vendor to re-furbish and repair the trash rake. Additionally, the licensee revised their procedures to include additional methods to clear ice from the trash bars. The inspectors determined that the performance deficiency was more than minor because it was associated with the Equipment Performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, the failure to have any mitigating systems available during weather conditions that could promote frazil icing of the lake intake increased the likelihood of a plant transient including a loss of essential service water event. A detailed risk evaluation was performed by an NRC Regional SRA and the finding was determined to be of very low safety significance (Green). This finding had a cross-cutting aspect in the Restoration component of the Problem Identification and Resolution cross-cutting area because the organization failed to take effective corrective action to address a non-functioning LSH trash rake in a timely manner commensurate with safety after restoring the equipment to Operations for use during weather conditions that could promote frazil icing conditions (P.3). |
| Site: | Braidwood |
|---|---|
| Report | IR 05000456/2014002 Section 1R01 |
| Date counted | Mar 31, 2014 (2014Q1) |
| Type: | Finding: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.01 |
| Inspectors (proximate) | A Garmoe E Duncan F Ramirez J Benjamin J Coroju Sandin M Perry T Go |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Braidwood - IR 05000456/2014002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|