Finding | |
---|---|
Title | Failure to Verify the CCW System Capability to Withstand a Thermal Barrier Break |
Description | The inspectors identified a finding of very low safety significance and associated Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure to ensure the component cooling water (CCW) system was capable of withstanding a reactor coolant pump thermal barrier break. Specifically, when assuming a single failure of the automatic isolation function, the licensee failed to evaluate the break effect on the CCW system during the 3 minutes postulated to isolate the leak. The licensee entered the issue into their corrective action program; verified the CCW system would be able to withstand the postulated event, and planned to perform a detailed evaluation of the effect of a thermal barrier break on the CCW system. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems Cornerstone attribute of Design Control and objective of ensuring the capability of the system to respond to an initiating event to prevent undesirable consequences. Specifically, the failure to evaluate the effect of the thermal barrier rupture on the CCW system created reasonable doubt whether the system would be capable of withstanding the applied forces of this event. The finding screened as very low safety significance (Green) because the design deficiency did not result in a loss of operability or functionality. The inspectors did not identify a cross-cutting aspect associated with this finding because the finding was not representative of current performance. |
Site: | Byron ![]() |
---|---|
Report | IR 05000454/2012007 Section 1R21 |
Date counted | Jun 30, 2012 (2012Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | A Dunlop R Langstaff C Brown C Baron J Chiloyan A Stone E Sanchez |
INPO aspect | |
' | |
Finding - Byron - IR 05000454/2012007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Byron) @ 2012Q2
Self-Identified List (Byron)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||