Finding | |
|---|---|
| Title | Failure to Correct A Significant Condition Adverse to Quality And Preclude Repetition |
| Description | The inspectors reviewed a self-revealing, Green, non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, resulting from the licensees failure to prevent the repetition of a break of the first stage turbine sensing line, which resulted in a reactor scram. The licensee documented this issue in their corrective action program as Condition Report CR-GGN-2014-02824. The failure to implement adequate corrective actions from the previous first stage turbine pressure sensing line break to preclude repetition of a significant condition adverse to quality was the performance deficiency. The performance deficiency was more than minor because it was associated with the Initiating Events cornerstone attribute of Human Performance and adversely affected the cornerstone objective of limiting the likelihood of events that upset plant stability and challenge critical safety functions during power operations. Using Inspection Manual Chapter 0609, Appendix A, Significance Determination Process (SDP) for Findings at Power, dated June 19, 2012, Exhibit 1, Section B, Transient Initiators, the inspectors determined that the issue required a detailed risk evaluation by the senior reactor analyst because the violation caused a reactor trip and the loss of mitigation equipment. The licensee performed an inadequate evaluation of the root cause of the 2012 steam sensing line break, resulting in inadequate corrective actions to prevent repetition. Therefore, this violation has a cross-cutting aspect in the problem identification and resolution performance area, associated with evaluation, because the licensee failed to thoroughly evaluate the issue to ensure that resolutions address causes and extent of conditions commensurate with their safety significance [P.2]. |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2014009 Section 4OA3 |
| Date counted | Jun 30, 2014 (2014Q2) |
| Type: | NCV: Green |
| cornerstone | Initiating Events |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | D Allen J Drake L Brandt N Greene |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Grand Gulf - IR 05000416/2014009 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2014Q2
Self-Identified List (Grand Gulf)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||