| | | Reporting criterion |
|---|
| 05000414/LER-1996-001-02, :on 960206,loss of Offsite Power Due to Electrical Component Failures Occurred.Caused by Application of Type of Resistor Bushing Used.All Resister Bushing in Application Replaced |
- on 960206,loss of Offsite Power Due to Electrical Component Failures Occurred.Caused by Application of Type of Resistor Bushing Used.All Resister Bushing in Application Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1996-001, Submits Modification to Commitment Contained in LER-96-001 | Submits Modification to Commitment Contained in LER-96-001 | |
| 05000414/LER-1996-002-03, :on 960318,TS Violation for Redundant Hydrogen Igniters Inoperable in Same Region Occurred.Caused by No Programmatic Requirements in Place Directing Maint to Perform Communication.Blown Fuse Replaced |
- on 960318,TS Violation for Redundant Hydrogen Igniters Inoperable in Same Region Occurred.Caused by No Programmatic Requirements in Place Directing Maint to Perform Communication.Blown Fuse Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1996-002-04, :on 960503,TS 3.0.3 Entered Due to Inconclusive Surveillance Testing.Caused by Ommission of Relevant Info & Inadequate Training.Reviewed Test Procedures & Trained Personnel Re Multimeter Use |
- on 960503,TS 3.0.3 Entered Due to Inconclusive Surveillance Testing.Caused by Ommission of Relevant Info & Inadequate Training.Reviewed Test Procedures & Trained Personnel Re Multimeter Use
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1996-003-06, :on 960802,TS 3.0.3 Required Shutdown Initiated,Due to Ventilation Sys Motor Failures.Unit 2 Was Shutdown to MOD 5 Per Requirements of TS 3.0.3.Damaged Motors Were Replaced |
- on 960802,TS 3.0.3 Required Shutdown Initiated,Due to Ventilation Sys Motor Failures.Unit 2 Was Shutdown to MOD 5 Per Requirements of TS 3.0.3.Damaged Motors Were Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1996-003-01, :on 960508,Control Rod Bank a Group 1 Failed to Withdraw from Inserted Test Position of 219 Steps.Caused by Failed Firing Card.Unit Shutdown to Mode 3 & Failed Firing Card Replaced W/Spare Firing Card |
- on 960508,Control Rod Bank a Group 1 Failed to Withdraw from Inserted Test Position of 219 Steps.Caused by Failed Firing Card.Unit Shutdown to Mode 3 & Failed Firing Card Replaced W/Spare Firing Card
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000414/LER-1996-003, Informs That Cover Sheet to LER 96-003,inadvertently Denoted Incorrectly Docket Number.Nrc Rept Forms 366 & 366A Correctly Identified Correct Docket Number | Informs That Cover Sheet to LER 96-003,inadvertently Denoted Incorrectly Docket Number.Nrc Rept Forms 366 & 366A Correctly Identified Correct Docket Number | |
| 05000414/LER-1996-004-03, :on 960806,containment Floor & Equipment Sump Level Alarm Was Inoperability Due to Operator Aid Computer Error.Replacement for Unit Is Taking Place During Current Outage.Oac Error Was Corrected & Replaced |
- on 960806,containment Floor & Equipment Sump Level Alarm Was Inoperability Due to Operator Aid Computer Error.Replacement for Unit Is Taking Place During Current Outage.Oac Error Was Corrected & Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1996-004-01, :on 960506,standby Shutdown Sys Found Outside Design Basis.Caused by Misinterpretation of Info.Changed Design Basis Document Based on Corrected Calculations & Implemented Mod to Ensure Water Availability |
- on 960506,standby Shutdown Sys Found Outside Design Basis.Caused by Misinterpretation of Info.Changed Design Basis Document Based on Corrected Calculations & Implemented Mod to Ensure Water Availability
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1996-005-01, :on 960613,automatic Reactor Trip Occurred. Caused by Failed Capacitor.Replaced & Tested Failed Capacitor |
- on 960613,automatic Reactor Trip Occurred. Caused by Failed Capacitor.Replaced & Tested Failed Capacitor
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000414/LER-1996-005-06, :on 961028,determined That Plant May Have Operated in Standby Shutdown Sys Potentially Outside of Design Basis.Caused by Inadequate Sys Design Bases.Placed Vent Valves in Planned Maint Schedule |
- on 961028,determined That Plant May Have Operated in Standby Shutdown Sys Potentially Outside of Design Basis.Caused by Inadequate Sys Design Bases.Placed Vent Valves in Planned Maint Schedule
| |
| 05000413/LER-1996-006-01, :on 960509,discovered Containment Floor and Equipment Sump Level Monitoring Inaccuracy.Caused by Inadequate Design Analysis.Added Water to Sumps to Ensure Sump Level Remains in Calibr Range |
- on 960509,discovered Containment Floor and Equipment Sump Level Monitoring Inaccuracy.Caused by Inadequate Design Analysis.Added Water to Sumps to Ensure Sump Level Remains in Calibr Range
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) |
| 05000414/LER-1996-006-02, :on 961101,TS Surveillance for AC Offsite Power Sources Was Missed.Caused by Insufficient Detail in Test Procedure.Quality Improvement Team Has Been Created to Track Short Duration Inoperabilities |
- on 961101,TS Surveillance for AC Offsite Power Sources Was Missed.Caused by Insufficient Detail in Test Procedure.Quality Improvement Team Has Been Created to Track Short Duration Inoperabilities
| |
| 05000414/LER-1996-007-03, :on 961216,ECCS Discharge Into Reactor Coolant Sys Occurred.Caused by Failure to Follow Procedures. Increased Nc Pressure to Close Cla Check Valves & Then Closed Cla Discharge Isolation Valves |
- on 961216,ECCS Discharge Into Reactor Coolant Sys Occurred.Caused by Failure to Follow Procedures. Increased Nc Pressure to Close Cla Check Valves & Then Closed Cla Discharge Isolation Valves
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000413/LER-1996-007-01, :on 960718,discovered MSSV Lift Setpoint Drift. Caused by Unanticipated Interaction of Components.Adjusted & Retested Valves & Submitted Application to Amend TS to Change Tolerance to Plus or Minus 3 Percent |
- on 960718,discovered MSSV Lift Setpoint Drift. Caused by Unanticipated Interaction of Components.Adjusted & Retested Valves & Submitted Application to Amend TS to Change Tolerance to Plus or Minus 3 Percent
| |
| 05000413/LER-1996-008-01, :on 950307,closure Response Time Was Exceeded for MSIV 1SM1,B Train.Caused by Spurious Failures of B Train Exhaust Solenoid Valve for 1SM1.Valves Used in Pnuematic Controls for Unit 1 Have Been Replaced |
- on 950307,closure Response Time Was Exceeded for MSIV 1SM1,B Train.Caused by Spurious Failures of B Train Exhaust Solenoid Valve for 1SM1.Valves Used in Pnuematic Controls for Unit 1 Have Been Replaced
| 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1996-009-02, :on 960930,use of Inadequate Reactor Coolant Controlled Leakage Test Occurred.Caused by Omission of Relevant TS Bases Info.Revised Procedures for Performing Reactor Coolant Sys Controlled Leakage Test |
- on 960930,use of Inadequate Reactor Coolant Controlled Leakage Test Occurred.Caused by Omission of Relevant TS Bases Info.Revised Procedures for Performing Reactor Coolant Sys Controlled Leakage Test
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1996-010, :on 961107,TS Surveillance for VY Sys Containment Isolation Valves Was Missed.Caused by Inadequate Verification of Pertinent Info During Implementation of Periodic Testing Program.Tested Valves |
- on 961107,TS Surveillance for VY Sys Containment Isolation Valves Was Missed.Caused by Inadequate Verification of Pertinent Info During Implementation of Periodic Testing Program.Tested Valves
| 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1996-011, :on 961210,cross Channel Check Comparison of Loops a & B W/Loops C & D Showed Setpoint Readings for All 4 Loops Were Incorrect.Caused by Slight Increase in Test Lead Resistance.Loops a & B Recalibrated |
- on 961210,cross Channel Check Comparison of Loops a & B W/Loops C & D Showed Setpoint Readings for All 4 Loops Were Incorrect.Caused by Slight Increase in Test Lead Resistance.Loops a & B Recalibrated
| |
| 05000413/LER-1996-012, :on 961211,auxiliary Feedwater Sys Found Outside Design Basis Occurred.Caused by Initial Design Oversight.Minor Mods Were Completed to Add Check Valves to Each Unit |
- on 961211,auxiliary Feedwater Sys Found Outside Design Basis Occurred.Caused by Initial Design Oversight.Minor Mods Were Completed to Add Check Valves to Each Unit
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000413/LER-1996-013, :on 961218,TS 3.4.6.1 Violation Occurred Due to an Error in Replacement Operator Aid Computer Programming.Computer Points Were Added to Replacement Oac & an Alarm Response Was Developed |
- on 961218,TS 3.4.6.1 Violation Occurred Due to an Error in Replacement Operator Aid Computer Programming.Computer Points Were Added to Replacement Oac & an Alarm Response Was Developed
| 10 CFR 50.73(a)(2)(viii)(A) |
| 05000413/LER-1996-014, :on 961230,solid State Protection Sys Train B Relay K616 Properly Actuated,Failed to Latch in Tripped Position During Periodic Main Steam Line Isolation Testing. Caused by Equipment failure.K616 Replaced |
- on 961230,solid State Protection Sys Train B Relay K616 Properly Actuated,Failed to Latch in Tripped Position During Periodic Main Steam Line Isolation Testing. Caused by Equipment failure.K616 Replaced
| |