| 05000413/LER-1998-001, Forwards LER 98-001-00 Re Both Trains of Control Room Area Ventilation Inadvertently Disabled During Restoration.Ltr Contains Commitments to Perform Corrective Actions | Forwards LER 98-001-00 Re Both Trains of Control Room Area Ventilation Inadvertently Disabled During Restoration.Ltr Contains Commitments to Perform Corrective Actions | |
| 05000413/LER-1998-001-02, :on 980205,boths Trains of CR Area Ventilation Inadvertently Disabled During Restoration.Caused by Inadequate Maint Procedure.Revised Procedure & Personnel Involved Have Been Counseled |
- on 980205,boths Trains of CR Area Ventilation Inadvertently Disabled During Restoration.Caused by Inadequate Maint Procedure.Revised Procedure & Personnel Involved Have Been Counseled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000414/LER-1998-001-04, :on 980312,both Trains of Unit 2 Annulus Ventilation Sys Became Inoperable.Caused by Inadequate Process for Determining Compensatory Actions Were Needed to Perform Work on Door.Improved Programs |
- on 980312,both Trains of Unit 2 Annulus Ventilation Sys Became Inoperable.Caused by Inadequate Process for Determining Compensatory Actions Were Needed to Perform Work on Door.Improved Programs
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) |
| 05000413/LER-1998-002, Forwards LER 98-002-00,incorrectly Set Valve Leads to Elevated Condensate Storage Sys Temperature,Causing Condition Outside Design Basis of Plant.Planned Corrective Actions Section of Rept Contain Commitments | Forwards LER 98-002-00,incorrectly Set Valve Leads to Elevated Condensate Storage Sys Temperature,Causing Condition Outside Design Basis of Plant.Planned Corrective Actions Section of Rept Contain Commitments | |
| 05000414/LER-1998-002-01, Forwards LER 98-002-01 Re Violation of Auxiliary Bldg Filtered Exhaust Ventilation Sys Tech Specs 3.7.7 Due to Exceeding Allowable Outage Time of TS Action Requirements for 2A Auxiliary Bldg Filtered Exhaust Sys | Forwards LER 98-002-01 Re Violation of Auxiliary Bldg Filtered Exhaust Ventilation Sys Tech Specs 3.7.7 Due to Exceeding Allowable Outage Time of TS Action Requirements for 2A Auxiliary Bldg Filtered Exhaust Sys | |
| 05000414/LER-1998-002-02, :on 980316,test Indicated That Min Flow Required by TS 3.7.7 Was Not Met.Caused by Inadequate Mgt Oversight of Operability Program.Corrective Actions Being Developed & Will Be Specified in Rev to Rept |
- on 980316,test Indicated That Min Flow Required by TS 3.7.7 Was Not Met.Caused by Inadequate Mgt Oversight of Operability Program.Corrective Actions Being Developed & Will Be Specified in Rev to Rept
| |
| 05000414/LER-1998-002, Forwards LER 98-002-00,addressing Violation of Auxiliary Bldg Filtered Exhaust Ventilation Sys TS 3.7.7.Event Considered to Be of No Significance W/Respect to Health & Safety of Public | Forwards LER 98-002-00,addressing Violation of Auxiliary Bldg Filtered Exhaust Ventilation Sys TS 3.7.7.Event Considered to Be of No Significance W/Respect to Health & Safety of Public | |
| 05000413/LER-1998-002-04, :on 980507,incorrectly Set Valve Leads to Elevated Condensate Storage Sys Temperature,Causing Condition Outside Design Basis of Plant,Was Noted.Caused by Inadequate Training.Alarm Response Guideline Revised |
- on 980507,incorrectly Set Valve Leads to Elevated Condensate Storage Sys Temperature,Causing Condition Outside Design Basis of Plant,Was Noted.Caused by Inadequate Training.Alarm Response Guideline Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2) |
| 05000414/LER-1998-003-04, :on 980713,channel 3 Overtemperature Delta T Setpoint Exceeded Allowable Value Which Resulted in TS 2.2.1 Violation.Caused by Inadequate Procedure.Procedure Was Corrected & Channel Was Recalibrated |
- on 980713,channel 3 Overtemperature Delta T Setpoint Exceeded Allowable Value Which Resulted in TS 2.2.1 Violation.Caused by Inadequate Procedure.Procedure Was Corrected & Channel Was Recalibrated
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2) |
| 05000413/LER-1998-003-01, :on 980218,omission in Retest Manual Leads to Failure to Perform Required Retest Prior to Restoring Ci Valves to Svc.Retest Manual Will Be Updated to Reflect Specific TS Requirements for Ci Valves |
- on 980218,omission in Retest Manual Leads to Failure to Perform Required Retest Prior to Restoring Ci Valves to Svc.Retest Manual Will Be Updated to Reflect Specific TS Requirements for Ci Valves
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(1) |
| 05000414/LER-1998-003, Forwards LER 98-003-00,re Violation of TS 2.2.1.Commitments Made within Ltr Are Contained in Planned Corrective Actions Section of Rept | Forwards LER 98-003-00,re Violation of TS 2.2.1.Commitments Made within Ltr Are Contained in Planned Corrective Actions Section of Rept | |
| 05000414/LER-1998-004, Forwards LER 98-004-00 Re de-energization of Vital Bus & Actuation of LTOP Caused by Error During Tagout.Commitments Are Contained in Planned Corrective Actions Section of LER | Forwards LER 98-004-00 Re de-energization of Vital Bus & Actuation of LTOP Caused by Error During Tagout.Commitments Are Contained in Planned Corrective Actions Section of LER | |
| 05000413/LER-1998-004-01, :on 980216,missed TS Surveillance on CR Area Ventilation Sys Actuation Instrumentation Noted.Caused by Incorrect Mode Specification Requirements in Affected Ts. Submitted License Amend & Verified TS Are Met |
- on 980216,missed TS Surveillance on CR Area Ventilation Sys Actuation Instrumentation Noted.Caused by Incorrect Mode Specification Requirements in Affected Ts. Submitted License Amend & Verified TS Are Met
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000414/LER-1998-004-04, :on 980906,de-energization of Vital Bus & Actuation of LTOP Occurred.Caused by Error During Tagout. Power Was Restored to 2ETB IAW Plant Procedure AP/2/A/5500/ 07 & Individuals Involved Were Counseled Re Subject Error |
- on 980906,de-energization of Vital Bus & Actuation of LTOP Occurred.Caused by Error During Tagout. Power Was Restored to 2ETB IAW Plant Procedure AP/2/A/5500/ 07 & Individuals Involved Were Counseled Re Subject Error
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1998-005, Forwards LER 98-005-00,re Missed TS Surveillance on Abv. Commitments Made within Ltr,Encl | Forwards LER 98-005-00,re Missed TS Surveillance on Abv. Commitments Made within Ltr,Encl | |
| 05000414/LER-1998-005, Forwards LER 98-005-00 Re Violation of TS 3.6.5.3 Due to Inoperability of Ice Condenser Inlet Doors Caused by Ice & Frost Buildup Restricting Door Movement.Three Regulatory Commitments Are Contained in Planned C/A Section of LE | Forwards LER 98-005-00 Re Violation of TS 3.6.5.3 Due to Inoperability of Ice Condenser Inlet Doors Caused by Ice & Frost Buildup Restricting Door Movement.Three Regulatory Commitments Are Contained in Planned C/A Section of LER | |
| 05000414/LER-1998-005-03, :on 980906,discovered Frost/Ice Buildup on Support Beam Coolers & Associated Glycol Lines in Ice Condenser.Caused by Inadequate Design.Frost/Ice Will Be Cleared from Coolers & Insulation Will Be Installed |
- on 980906,discovered Frost/Ice Buildup on Support Beam Coolers & Associated Glycol Lines in Ice Condenser.Caused by Inadequate Design.Frost/Ice Will Be Cleared from Coolers & Insulation Will Be Installed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000414/LER-1998-005-01, Forwards LER 98-005-01 Re Violation of Tech Spec 3.6.5.3,due to Inoperability of Condenser Inlet Doors,Caused by Ice/ Frost Buildup Restricting Door Movement.Ler Has Been Revised to Perform More Limited Direct Visual Insp | Forwards LER 98-005-01 Re Violation of Tech Spec 3.6.5.3,due to Inoperability of Condenser Inlet Doors,Caused by Ice/ Frost Buildup Restricting Door Movement.Ler Has Been Revised to Perform More Limited Direct Visual Insp | |
| 05000414/LER-1998-005-02, :on 980906,engineering Personnel Discovered Frost/Ice Buildup on Support Beam Coolers & Associated Glycol Lines in Ice Condenser.Caused by Inadequate Design. Frost/Ice Will Be Cleaned & Insulation Will Be Installed |
- on 980906,engineering Personnel Discovered Frost/Ice Buildup on Support Beam Coolers & Associated Glycol Lines in Ice Condenser.Caused by Inadequate Design. Frost/Ice Will Be Cleaned & Insulation Will Be Installed
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1998-005-01, :on 980514,missed TS Surveillance on Abv Sys. Caused by Misinterpretation of TS SR 4.7.7.d.1.Entered Both Trains of Auxiliary Building Filtered Exhaust Sys of Both Units in TS 4.0.3 |
- on 980514,missed TS Surveillance on Abv Sys. Caused by Misinterpretation of TS SR 4.7.7.d.1.Entered Both Trains of Auxiliary Building Filtered Exhaust Sys of Both Units in TS 4.0.3
| 10 CFR 50.73(a)(2) |
| 05000414/LER-1998-006, Forwards LER 98-006-00 Re Rod Control Sys Malfunction Due to Failed Card Leading to Manual Reactor Trip.Commitments Are Provided in Planned Corrective Action Section of LER | Forwards LER 98-006-00 Re Rod Control Sys Malfunction Due to Failed Card Leading to Manual Reactor Trip.Commitments Are Provided in Planned Corrective Action Section of LER | |
| 05000413/LER-1998-006, Forwards LER 98-006-00,re Missed TS Surveillance on Pressurizer Heater Emergency Power Supply Testing. Commitments Made within Ltr,Encl | Forwards LER 98-006-00,re Missed TS Surveillance on Pressurizer Heater Emergency Power Supply Testing. Commitments Made within Ltr,Encl | |
| 05000414/LER-1998-006-04, :on 981021,rod Control Sys Malfunction Occurred Due to Failed Card Leading to Manual Reactor Trip & Esf. Reactor Startup Was Suspended & Troubleshooting Efforts Were Initiated & Slave Cycler Lift Decoder Card Was Replaced |
- on 981021,rod Control Sys Malfunction Occurred Due to Failed Card Leading to Manual Reactor Trip & Esf. Reactor Startup Was Suspended & Troubleshooting Efforts Were Initiated & Slave Cycler Lift Decoder Card Was Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) |
| 05000413/LER-1998-006-01, :on 980514,missed TS Surveillance on Pressurizer Heater EP Supply Testing.Caused by Incompatible W/Sys Design.License Amend Was Submitted to Revise SR 4.4.3.3 |
- on 980514,missed TS Surveillance on Pressurizer Heater EP Supply Testing.Caused by Incompatible W/Sys Design.License Amend Was Submitted to Revise SR 4.4.3.3
| 10 CFR 50.73(a)(2) |
| 05000414/LER-1998-007, Forwards LER 98-007-00,re Inoperability of Overtemperature & Overpower Delta Temp Functions.Commitments Are Provided in Planned Corrective Action Section of Attached Rept | Forwards LER 98-007-00,re Inoperability of Overtemperature & Overpower Delta Temp Functions.Commitments Are Provided in Planned Corrective Action Section of Attached Rept | |
| 05000414/LER-1998-007-03, :on 981211,mispositioned Thumbwheel on Process CS Circuit Card Caused Inoperability of Overtemperature & Overpower Delta Temp Functions.Caused by Inadequate Program Design.Revised Procedures |
- on 981211,mispositioned Thumbwheel on Process CS Circuit Card Caused Inoperability of Overtemperature & Overpower Delta Temp Functions.Caused by Inadequate Program Design.Revised Procedures
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1998-007, Forwards LER 98-007-00,concerning Missed TS Surveillance on Containment Penetration Testing Due to Literal Compliance Issue | Forwards LER 98-007-00,concerning Missed TS Surveillance on Containment Penetration Testing Due to Literal Compliance Issue | |
| 05000413/LER-1998-007-01, :on 980608,missed TS Surveillance on Containment Penetration Testing Due to Literal Compliance Issue.Caused by Inappropriate Implementation of Staggered Test Requirement.Affected Penetrations Successfully Tested |
- on 980608,missed TS Surveillance on Containment Penetration Testing Due to Literal Compliance Issue.Caused by Inappropriate Implementation of Staggered Test Requirement.Affected Penetrations Successfully Tested
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1998-008, :on 980611,noncompliance W/Ts Requirements for Wgs O Analyzers Was Noted.Caused by Error in Interpretation of TS Requirements.Procedures Revised |
- on 980611,noncompliance W/Ts Requirements for Wgs O Analyzers Was Noted.Caused by Error in Interpretation of TS Requirements.Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2) |
| 05000413/LER-1998-009-01, :on 980722,unit Entered TS 3.0.3 Due to Inadequate Testing of Auxiliary Building Filtered Exhaust Sys.Caused by Inadequate Procedure.Initiated 24 H Allowance of TS 4.0.3 for Missed Procedure |
- on 980722,unit Entered TS 3.0.3 Due to Inadequate Testing of Auxiliary Building Filtered Exhaust Sys.Caused by Inadequate Procedure.Initiated 24 H Allowance of TS 4.0.3 for Missed Procedure
| |
| 05000413/LER-1998-009, Forwards LER 98-009-00,concerning Unit Entering TS 3.0.3 Due to Inadequate Testing of Auxiliary Bldg Filtered Exhaust Sys | Forwards LER 98-009-00,concerning Unit Entering TS 3.0.3 Due to Inadequate Testing of Auxiliary Bldg Filtered Exhaust Sys | |
| 05000413/LER-1998-010, :on 980624,pinhole Leak in AFW Nozzle Tempering Line Caused Noncompliance W/Ts Structural Integrity Requirements.Caused by Previous Accelerated Flow Rates & Improper Socket Weld Fit Up.Isolated Piping Containing Hole |
- on 980624,pinhole Leak in AFW Nozzle Tempering Line Caused Noncompliance W/Ts Structural Integrity Requirements.Caused by Previous Accelerated Flow Rates & Improper Socket Weld Fit Up.Isolated Piping Containing Hole
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000413/LER-1998-010-01, Forwards LER 98-010-01,re Pin Hole Leak in AFW Nozzle Tempering Line.Supplemental Rept Provides Results of Engineering Evaluation.Commitments Are in Planned C/A Section of LER | Forwards LER 98-010-01,re Pin Hole Leak in AFW Nozzle Tempering Line.Supplemental Rept Provides Results of Engineering Evaluation.Commitments Are in Planned C/A Section of LER | |
| 05000413/LER-1998-011, :on 980723,discovered That Two RWST Level Channels Were Inoperable.Caused by Ground Currents from Lightning Strikes.Level Transmitters Were Replaced & Recalibr & Initiated Compensatory Measures |
- on 980723,discovered That Two RWST Level Channels Were Inoperable.Caused by Ground Currents from Lightning Strikes.Level Transmitters Were Replaced & Recalibr & Initiated Compensatory Measures
| 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000413/LER-1998-012-01, Forwards LER 98-012-01 Re TS 3.0,3 Entry Due to Inoperability of Both Trains of CR Ventilation.Caused by Improper Sys Isolation.Only Commitments Identified in Rept, Listed Under Planned Corrective Actions Section | Forwards LER 98-012-01 Re TS 3.0,3 Entry Due to Inoperability of Both Trains of CR Ventilation.Caused by Improper Sys Isolation.Only Commitments Identified in Rept, Listed Under Planned Corrective Actions Section | |
| 05000413/LER-1998-012, :on 980706,entered TS 3.0.3 Due to Inoperability of Both Trains of CR Ventilation.Caused by Improper Sys Isolation.Properly Secured Damper in Closed Position & Will Revise Applicable Damper Procedures |
- on 980706,entered TS 3.0.3 Due to Inoperability of Both Trains of CR Ventilation.Caused by Improper Sys Isolation.Properly Secured Damper in Closed Position & Will Revise Applicable Damper Procedures
| 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1998-013, :on 980709,noncompliance W/Tech Specs Identified During Review of Radiation Protection Procedure. Caused by Incorrect TS Requirements Contained in Radiation Protection Procedures.Procedures Revised |
- on 980709,noncompliance W/Tech Specs Identified During Review of Radiation Protection Procedure. Caused by Incorrect TS Requirements Contained in Radiation Protection Procedures.Procedures Revised
| 10 CFR 50.73(a)(2)(x) |
| 05000413/LER-1998-013-01, Forwards LER 98-013-01 Re Operation Outside of Tech Specs Due to Analyzing Grab Samples at Incorrect Lower of Detection.Two Regulatory Commitments Contained in Planned Corrective Actions Section of Rept | Forwards LER 98-013-01 Re Operation Outside of Tech Specs Due to Analyzing Grab Samples at Incorrect Lower of Detection.Two Regulatory Commitments Contained in Planned Corrective Actions Section of Rept | |
| 05000413/LER-1998-014, :on 980805,both DGs Inoperable,Resulting in Failure to Perform DG Surveillance within Required Surveillance Interval,Was Revealed.Caused by Misinterpretation of Ts.Ts 4.0.3 Entered |
- on 980805,both DGs Inoperable,Resulting in Failure to Perform DG Surveillance within Required Surveillance Interval,Was Revealed.Caused by Misinterpretation of Ts.Ts 4.0.3 Entered
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1998-015-01, Forwards LER 98-015-01, TS Required Shutdown & Operation Prohibited by TS Associated with Ice Condenser. Rev 0 to Ler,Dtd 980902,contained Abstract Since Event Investigation Had Not Been Completed.Rev 1 Contains All 10CFR50. | Forwards LER 98-015-01, TS Required Shutdown & Operation Prohibited by TS Associated with Ice Condenser. Rev 0 to Ler,Dtd 980902,contained Abstract Since Event Investigation Had Not Been Completed.Rev 1 Contains All 10CFR50.73 Info | |
| 05000413/LER-1998-015, :on 980805,TS Required Shutdown & Operation Prohibited by TS Associated W/Ice Condenser,Was Initiated. Caused by Lack of Procedural Guidance.Flow Channels Cleared, Foreign Matl Removed,Dented Baskets Repaired |
- on 980805,TS Required Shutdown & Operation Prohibited by TS Associated W/Ice Condenser,Was Initiated. Caused by Lack of Procedural Guidance.Flow Channels Cleared, Foreign Matl Removed,Dented Baskets Repaired
| 10 CFR 50.73(a)(2) |
| 05000413/LER-1998-016, :on 981020,determined That Plant Was in Condition Outside Design Basis Due to Discovery of Missing Interlock.Caused by Failure to Coordinate Licensing Commitment.Licensee Will Install Interlock,Per UFSAR |
- on 981020,determined That Plant Was in Condition Outside Design Basis Due to Discovery of Missing Interlock.Caused by Failure to Coordinate Licensing Commitment.Licensee Will Install Interlock,Per UFSAR
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1998-017, :on 981015,TS SR on Standby Shutdown Sys Instrumentation Was Missed.Caused by Inadequate Change Mgt Process.Calibrated Affected Resistance Temp Detectors & Modified Procedure.With |
- on 981015,TS SR on Standby Shutdown Sys Instrumentation Was Missed.Caused by Inadequate Change Mgt Process.Calibrated Affected Resistance Temp Detectors & Modified Procedure.With
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000413/LER-1998-018-01, :on 981214,identified That There No Single Procedure That Specifically Verified Response Time for Two SI RT Functions.Caused by Inadequate Procedures.Procedures Will Be Revised &/Or Developed.With |
- on 981214,identified That There No Single Procedure That Specifically Verified Response Time for Two SI RT Functions.Caused by Inadequate Procedures.Procedures Will Be Revised &/Or Developed.With
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000413/LER-1998-019, Forwards LER 98-019-00 Re Inoperable Standby Shutdown Facility in Excess of TS AOT Due to Mispositioned Breakers. One Regulatory Commitment Is Contained in Planned Corrective Actions Section of Rept | Forwards LER 98-019-00 Re Inoperable Standby Shutdown Facility in Excess of TS AOT Due to Mispositioned Breakers. One Regulatory Commitment Is Contained in Planned Corrective Actions Section of Rept | |