Finding | |
|---|---|
| Title | Failure to Provide Procedures to Control and Adjust the Manipulator Crane Gear Limit Setpoints |
| Description | A self-revealing Green NCV of Technical Specification (TS) 6.8.1, Procedures, was identified when the licensee failed to follow Attachment 4, Manipulator Crane and Auxiliary Hoist Checkout, of Fuel Handling Procedure 20 (FHP-020), Refueling Operations, resulting in damaged grid straps on two fuel assemblies on April 23, 2009. Specifically, the value of the manipulator crane gear limit setpoints for the lower core slow zone exceeded the values allowed by the checkout procedure. This resulted in the fuel handlers damaging the grid straps on two successive fuel assembly moves. The licensee entered this issue into their corrective action program (CAP) as action request (AR) #332368. As corrective actions, the licensee suspended the core offload, reset the lower core slow zone within tolerance, and permanently discharged the affected fuel assemblies. Additionally, the licensee committed to revise FHP-020 prior to the next refueling outage in order to prevent recurrence. The violation was more than minor because it is associated with the human performance attribute of the Barrier Integrity cornerstone, and it affected the cornerstone objective of providing reasonable assurance that physical design barriers (fuel cladding, reactor coolant system, and containment) protect the public from radionuclide releases caused by accidents or events. The finding was determined to be of very low safety significance because it was a deficiency associated with fuel handling errors that did not cause damage to fuel clad integrity or a dropped fuel assembly. The finding has a crosscutting aspect of Procedural Compliance, as described in the Work Practices component of the Human Performance cross-cutting area because the licensee accepted the out of tolerance values that were outside the acceptance criteria of the procedure (H.4(b)). (Section 4OA2 |
| Site: | Harris |
|---|---|
| Report | IR 05000400/2009003 Section 4OA2 |
| Date counted | Jun 30, 2009 (2009Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems, Barrier Integrity |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | W Loo J Austin M Bates R Chou R Musser P Lessard D Forbes |
| CCA | H.8, Procedure Adherence |
| INPO aspect | WP.4 |
| ' | |
Finding - Harris - IR 05000400/2009003 | ||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Harris) @ 2009Q2
Self-Identified List (Harris)
| ||||||||||||||||||||||||||||||||||||||||||||||||||