Finding | |
|---|---|
| Title | Potential Failure to Inspect Containment Post-Tensioned Tendons per Code Requirements and to Follow Corrective Action Program Process |
| Description | Vertical and horizontal post tensioned tendons, along with reinforcing steel, are required to maintain structural integrity of the primary containment. There are a total of 120 vertical post tensioned tendons along the periphery of the primary containment wall, including 60 Group C tendons and 30 each of Groups A and B. Section 5.5.6 of the Technical Specifications describes the Inservice Inspection (ISI) program for post tensioning tendons and states that the Tendon Surveillance Program shall be in accordance with ASME Section XI, Subsection IWL as required by 10 CFR 50.55a. One Group B tendon (V213B) on Unit 1 was inspected in 1999 and according to the inspection records, water was identified on all components of the tendon. No presence of water is one of the acceptance criteria per Subsection IWL of the ASME Section XI. No condition report was found for this adverse condition. Subsequently, a condition involving degraded vertical tendons was identified during inspections in 2003 and documented in AR 157920157920 The degradation consisted of broken wires. The Root Cause Report (RCR) for this condition noted that 11 Group A tendons were found degraded and water induced corrosion was the root cause for tendon degradation. The evaluation concluded that five Group A tendons and all 30 Group B tendons in each unit were not susceptible to water intrusion because they were protected by welded covers. These tendons with welded covers were also determined to be inaccessible, and therefore exempt from future inspections requirements in accordance with provisions of ASME Section XI, IWL. The RCR did not address the condition of water found during the Group B tendon inspection in 1999. Additionally, to verify this assumption of welded covers providing protection from water intrusion, a corrective action was generated to inspect one Group A and one Group B inaccessible tendons during the next outage. Pertaining to inaccessible tendons, the inspectors noted the following requirements of 10 CFR 50.55a(b)(2)(viii)(E): Concrete containment examinations: Fifth provision. For Class CC applications, the applicant or licensee must evaluate the acceptability of inaccessible areas when conditions exist in accessible areas that could indicate the presence of or the result in degradation to such inaccessible areas. For each inaccessible area identified, the applicant or licensee must provide the following in the ISI Summary Report required by IWA6000: (1) A description of the type and estimated extent of degradation, and the conditions that led to the degradation; (2) An evaluation of each area, and the result of the evaluation; and (3) A description of necessary corrective actions. After the licensee identified degraded group A tendon locations, to comply with the provision of 10 CFR 50.55a, the licensee documented in its 90 day post outage ISI reports information on the degraded A tendons in 2004 and 2005 for units 1 and 2, respectively. This information included an assumption that the extent of degradation did not apply to the Group B tendon locations because of a welded cover at locations that precluded entry of water. Additionally, a corrective action, CA 15792033, was generated to inspect one Group A and one Group B tendon during the next refueling outage to verify this assumption. The corrective action was closed without inspection of any Group B tendon based on a management decision following satisfactory inspection of a Group A tendon in 2006. The licensees decision failed to take into account the fact that the most recent inspection of a Group B tendon showed presence of water on tendon components and also that the welded closure details were different for tendons in the two groups. Subsequently, the licensee identified a concern regarding inadequate closure of this corrective action during its reviews for the license renewal application in 2014. Specifically, the licensee wrote AR 1658189 to document that due to the differences in the welded cover designs, the results of the Group A tendon inspection may not be applicable to Group B tendons. Therefore the critical assumption regarding the adequacy of Group B tendon covers remained unverified. In particular, the Group B tendon cover used dissimilar metal welds and water was found inside the cover during the most recent inspection. The licensee identified actions to perform inspections on two of the Group B tendons on each unit in addition to inspecting the tendon V213B where water was initially found. These actions were categorized as action tracking items (ACITs), items that do not represent conditions adverse to quality. Since water was found on all tendon components during the last inspection of a Group B tendon, and water induced corrosion was found to be the root cause of many tendon failures, the assumption in the RCR that the welded covers would prevent water intrusion needed to be validated through inspections. This unresolved item remains open pending additional inspector review of the issue with respect to regulatory requirements. Planned Closure Action: Inspectors will seek additional information from the licensee and the NRC will perform internal review to evaluate compliance with NRC regulations. |
| Site: | LaSalle |
|---|---|
| Report | IR 05000373/2018003 Section 4OA2 |
| Date counted | Sep 30, 2018 (2018Q3) |
| Type: | URI: |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | W Schuap J Havertape R Ng J Cassidy G Edwards V Petrella L Rodriguez B Dickson |
| Violation of: | Pending |
| INPO aspect | |
| ' | |
Finding - LaSalle - IR 05000373/2018003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (LaSalle) @ 2018Q3
Self-Identified List (LaSalle)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||