| | | Reporting criterion |
|---|
| 05000369/LER-1983-001-03, /03L-0:on 830105,during Review of 791220 Safety Injection (SI) Pumps & Flow Adjustment Functional Test II, Discrepancy Discovered Between Test Data & Omitted Acceptance Criteria.Caused by Procedure Error | /03L-0:on 830105,during Review of 791220 Safety Injection (SI) Pumps & Flow Adjustment Functional Test II, Discrepancy Discovered Between Test Data & Omitted Acceptance Criteria.Caused by Procedure Error | |
| 05000369/LER-1983-002-03, /03L-0:on 830110,while in Mode 1,pressurizer Heater Group 1B Failed to Energize in Manual & Declared Inoperable.Cause Under Investigation.Design Defect Indicated in Vacuum Breaker Contractor Coil Circuit | /03L-0:on 830110,while in Mode 1,pressurizer Heater Group 1B Failed to Energize in Manual & Declared Inoperable.Cause Under Investigation.Design Defect Indicated in Vacuum Breaker Contractor Coil Circuit | |
| 05000369/LER-1983-002, Forwards LER 83-002/03L-0 | Forwards LER 83-002/03L-0 | |
| 05000369/LER-1983-003-03, /03L-0:on 830117,during Mode 1 Weekly Sampling Collection,Conventional Waste Water Treatment Composite Sampler Found Inoperable.Caused by Frozen Sample Line Due to Improper Installation of Insulation.Insulation Reinstalled | /03L-0:on 830117,during Mode 1 Weekly Sampling Collection,Conventional Waste Water Treatment Composite Sampler Found Inoperable.Caused by Frozen Sample Line Due to Improper Installation of Insulation.Insulation Reinstalled | |
| 05000369/LER-1983-003, Forwards LER 83-003/03L-0 | Forwards LER 83-003/03L-0 | |
| 05000369/LER-1983-004-03, /03L-0:on 830121,during Monthly Battery Insp,Cell 9 of Battery Evca Had Specific Gravity Below Tech Spec Limit.Caused by Normal Degradation.Bus Evda Tied to Operable Battery Bank.Cell 9 Jumpered Out & Battery Returned to Svc | /03L-0:on 830121,during Monthly Battery Insp,Cell 9 of Battery Evca Had Specific Gravity Below Tech Spec Limit.Caused by Normal Degradation.Bus Evda Tied to Operable Battery Bank.Cell 9 Jumpered Out & Battery Returned to Svc | |
| 05000369/LER-1983-004, Forwards LER 83-004/03L-0 | Forwards LER 83-004/03L-0 | |
| 05000369/LER-1983-005-03, /03L-0:on 830127,while in Mode 5,evaluation of Initial Ice Condenser Basket Weights Found Numerous Accessible Row 8 & 9 Baskets Had Net Ice Weights Below Tech Specs.Caused by Heat Loading & Air Current | /03L-0:on 830127,while in Mode 5,evaluation of Initial Ice Condenser Basket Weights Found Numerous Accessible Row 8 & 9 Baskets Had Net Ice Weights Below Tech Specs.Caused by Heat Loading & Air Current | |
| 05000369/LER-1983-005, Forwards LER 83-005/03L-0.Detailed Event Analysis Encl | Forwards LER 83-005/03L-0.Detailed Event Analysis Encl | |
| 05000369/LER-1983-006-03, /03L-0:on 830131,unit Changed from Mode 5 to 6 W/ Control Room Area Outside Air Pressure Filter Train 2 (VC-B) Inoperable.Subj Train & VC Train a Inoperable on 830125,26 & 29.Caused by Misinterpretation of Tech Specs | /03L-0:on 830131,unit Changed from Mode 5 to 6 W/ Control Room Area Outside Air Pressure Filter Train 2 (VC-B) Inoperable.Subj Train & VC Train a Inoperable on 830125,26 & 29.Caused by Misinterpretation of Tech Specs | |
| 05000369/LER-1983-006, Forwards LER 83-006/03L-0.Detailed Event Analysis Encl | Forwards LER 83-006/03L-0.Detailed Event Analysis Encl | |
| 05000369/LER-1983-007-03, /03L-0:on 830131,vent Radiation Monitors 1EMF-35, 36 & 37 Declared Inoperable Following Loss of Sample Flow Alarm.Caused by Clogged Charcoal Filter.Filter Replaced | /03L-0:on 830131,vent Radiation Monitors 1EMF-35, 36 & 37 Declared Inoperable Following Loss of Sample Flow Alarm.Caused by Clogged Charcoal Filter.Filter Replaced | |
| 05000369/LER-1983-007, Forwards LER 83-007/03L-0 | Forwards LER 83-007/03L-0 | |
| 05000369/LER-1983-008-03, /03L-0:on 830124,weekly Composite Sample Analysis Not Performed for Conventional Waste Water Treatment Sys Continuous Discharge.Caused by Personnel Error & Procedural Deficiency.Procedures Will Be Changed by 830331 | /03L-0:on 830124,weekly Composite Sample Analysis Not Performed for Conventional Waste Water Treatment Sys Continuous Discharge.Caused by Personnel Error & Procedural Deficiency.Procedures Will Be Changed by 830331 | |
| 05000369/LER-1983-008, Forwards LER 83-008/03L-0 | Forwards LER 83-008/03L-0 | |
| 05000369/LER-1983-009, Forwards LER 83-009/03L-0.Detailed Event Analysis Encl | Forwards LER 83-009/03L-0.Detailed Event Analysis Encl | |
| 05000369/LER-1983-009-03, /03L-0:on 821112,during Troubleshooting & Checkout Activities Following Diesel Generator Mod Work,Diesel Generator 1B Experienced Failures.Caused by Wires on Wrong Terminal,Burned Diodes & Spurious Low Crankcase Signals | /03L-0:on 821112,during Troubleshooting & Checkout Activities Following Diesel Generator Mod Work,Diesel Generator 1B Experienced Failures.Caused by Wires on Wrong Terminal,Burned Diodes & Spurious Low Crankcase Signals | |
| 05000369/LER-1983-010, Forwards LER 83-010/03L-0 | Forwards LER 83-010/03L-0 | |
| 05000369/LER-1983-010-03, /03L-0:on 830216,while in Mode 6,control Room Outside Air Intake Radiation Monitors 1EMF-43A &43B Declared Inoperable.Caused by Personnel Error.Monitors Returned to Svc & Inlet Valves Opened After Testing | /03L-0:on 830216,while in Mode 6,control Room Outside Air Intake Radiation Monitors 1EMF-43A &43B Declared Inoperable.Caused by Personnel Error.Monitors Returned to Svc & Inlet Valves Opened After Testing | |
| 05000369/LER-1983-011-01, While Core Unloaded During Fuel Assembly insp,21 of 94 Nonfuel Bearing Components Equipped W/Same Spring Design Discovered W/Broken Holddown Springs.Caused by Design Deficiency | While Core Unloaded During Fuel Assembly insp,21 of 94 Nonfuel Bearing Components Equipped W/Same Spring Design Discovered W/Broken Holddown Springs.Caused by Design Deficiency | |
| 05000369/LER-1983-011, Forwards LER 83-011/01T-0.Detailed Event Analysis Encl | Forwards LER 83-011/01T-0.Detailed Event Analysis Encl | |
| 05000369/LER-1983-012-03, /03L-0:on 830302,four Existing Auxiliary Feedwater Flow Transmitters Determined Not Environmentally Qualified for 330 F Main Steam Break Environ.Transmitter Overlooked in Review Response to NUREG-0588 | /03L-0:on 830302,four Existing Auxiliary Feedwater Flow Transmitters Determined Not Environmentally Qualified for 330 F Main Steam Break Environ.Transmitter Overlooked in Review Response to NUREG-0588 | |
| 05000369/LER-1983-012, Forwards LER 83-012/03L-0 | Forwards LER 83-012/03L-0 | |
| 05000369/LER-1983-013-03, /03L-0:on 830315,during Upperhead Injection Level Switch Calibr,Switches Found Out of Tolerance.Caused by Design Deficiency.Rev to Tech Specs Changing Switch Setpoint Submitted | /03L-0:on 830315,during Upperhead Injection Level Switch Calibr,Switches Found Out of Tolerance.Caused by Design Deficiency.Rev to Tech Specs Changing Switch Setpoint Submitted | |
| 05000369/LER-1983-013, Forwards LER 83-013/03L-0.Detailed Event Analysis Encl | Forwards LER 83-013/03L-0.Detailed Event Analysis Encl | |
| 05000369/LER-1983-014-03, /03L-0:on 830303,routine Surveillance on Conventional Waste Water Sys Radiation Monitor 1EMF-31 Found Channel Out of Tolerance.Caused by Cracked Detector Crystal. Crystal Replaced W/High Temp Crystal | /03L-0:on 830303,routine Surveillance on Conventional Waste Water Sys Radiation Monitor 1EMF-31 Found Channel Out of Tolerance.Caused by Cracked Detector Crystal. Crystal Replaced W/High Temp Crystal | |
| 05000369/LER-1983-014, Forwards LER 83-014/03L-0 | Forwards LER 83-014/03L-0 | |
| 05000369/LER-1983-015, Forwards LER 83-015/03L-0 & 83-003/03L-0 | Forwards LER 83-015/03L-0 & 83-003/03L-0 | |
| 05000369/LER-1983-015-03, /03L-0:on 830319 & 31,reactor Trip Breaker a Failed to Open on Undervoltage (UV) Trip Signal & Bypass Breaker B Failed to Trip on UV Signal,Respectively.Caused by Mechanical Problems W/Uv Mechanisms.Logic Modified | /03L-0:on 830319 & 31,reactor Trip Breaker a Failed to Open on Undervoltage (UV) Trip Signal & Bypass Breaker B Failed to Trip on UV Signal,Respectively.Caused by Mechanical Problems W/Uv Mechanisms.Logic Modified | |
| 05000369/LER-1983-016-03, /03L-0:on 830327,hanger 1MCA-ND-H260 Discovered Pulled Loose from Wall Anchors & Snubbers 1MCA-ND-H177 & H317 Found Locked Up During Subsequent full-stroking.Caused by Water Hammer Event Resulting in Void Formation | /03L-0:on 830327,hanger 1MCA-ND-H260 Discovered Pulled Loose from Wall Anchors & Snubbers 1MCA-ND-H177 & H317 Found Locked Up During Subsequent full-stroking.Caused by Water Hammer Event Resulting in Void Formation | |
| 05000369/LER-1983-016, Forwards LER 83-016/03L-0 | Forwards LER 83-016/03L-0 | |
| 05000369/LER-1983-017-03, /03L-0:on 830405,during Draining of Refueling Cavity RHR (Nd) Pumps Began to Cavitate & Eventually Both Nd Pumps Stopped.Caused by Level Gauge Isolation.Cavity Refilled.Nd Sys Vented.Procedures Revised | /03L-0:on 830405,during Draining of Refueling Cavity RHR (Nd) Pumps Began to Cavitate & Eventually Both Nd Pumps Stopped.Caused by Level Gauge Isolation.Cavity Refilled.Nd Sys Vented.Procedures Revised | |
| 05000369/LER-1983-017, Forwards LER 83-017/03L-0 | Forwards LER 83-017/03L-0 | |
| 05000369/LER-1983-018-03, /03L-0:on 830407,following Identification of Inoperable RHR Sys (Nd) Hanger & Snubbers,Sys Walkdown Revealed Addl Hanger Failure.Caused by Nd Sys Water Hammer. Hangers Repaired & Procedures Revised | /03L-0:on 830407,following Identification of Inoperable RHR Sys (Nd) Hanger & Snubbers,Sys Walkdown Revealed Addl Hanger Failure.Caused by Nd Sys Water Hammer. Hangers Repaired & Procedures Revised | |
| 05000369/LER-1983-019-03, /03L-0:on 830413,representative Fuel Pool Ventilation Sys Carbon Filter Sample Analysis Indicated Sample Failed to Meet Methyl Iodide Penetration Criteria. Sample Analyses Made to Determine Cause | /03L-0:on 830413,representative Fuel Pool Ventilation Sys Carbon Filter Sample Analysis Indicated Sample Failed to Meet Methyl Iodide Penetration Criteria. Sample Analyses Made to Determine Cause | |
| 05000369/LER-1983-020-01, /01T-0:on 830503,soap Bubble Test of 47 Secondary Containment Bypass Leakage Paths Not Performed During Initial Integrated Leak Rate Test.Caused by Procedural Deficiency.Procedures Revised | /01T-0:on 830503,soap Bubble Test of 47 Secondary Containment Bypass Leakage Paths Not Performed During Initial Integrated Leak Rate Test.Caused by Procedural Deficiency.Procedures Revised | |
| 05000369/LER-1983-021-03, /03L-0:on 830419,while in Mode 5,nuclear Svc Water Sys Valve 1RN-69 Actuator W/Mechanical Latch Replaced by Actuator Requiring Electrical Antihammer Circuit.Caused by Deficient Procedure | /03L-0:on 830419,while in Mode 5,nuclear Svc Water Sys Valve 1RN-69 Actuator W/Mechanical Latch Replaced by Actuator Requiring Electrical Antihammer Circuit.Caused by Deficient Procedure | |
| 05000369/LER-1983-022-03, /03L-0:on 830421,bellows Leak Test Not Performed on Penetration M354 After Initial Integrated Leak Rate Test.Caused by Procedural Deficiency Since Penetration Not Listed in Initial Procedures | /03L-0:on 830421,bellows Leak Test Not Performed on Penetration M354 After Initial Integrated Leak Rate Test.Caused by Procedural Deficiency Since Penetration Not Listed in Initial Procedures | |
| 05000369/LER-1983-023-01, /01T-0:on 830506,discovered That RHR Sys (Nd) Train a Improperly Declared Operable on 830423 & Subsequent Change from Mode 5 to Mode 4 Occurred on 830428.Caused by Water Hammer Failures | /01T-0:on 830506,discovered That RHR Sys (Nd) Train a Improperly Declared Operable on 830423 & Subsequent Change from Mode 5 to Mode 4 Occurred on 830428.Caused by Water Hammer Failures | |
| 05000369/LER-1983-024-03, /03L-0:on 830426,Fire Door 1000B Declared Inoperable When Damage,Consisting of Bent Door,Broken Hinge, Bent Hinge,Broken Door Lock & Broken Door Closer Discovered. Cause Unknown.Fire Watch Established | /03L-0:on 830426,Fire Door 1000B Declared Inoperable When Damage,Consisting of Bent Door,Broken Hinge, Bent Hinge,Broken Door Lock & Broken Door Closer Discovered. Cause Unknown.Fire Watch Established | |
| 05000369/LER-1983-025-03, /03L-0:on 830508,while in Mode 2,fire Detection Sys Zones 72 & 149 Declared Inoperable Due to Alarms Remaining in Alarm Condition.Fire Watch Patrols Established. Caused by Control Interface Module failure.W830527 Ltr | /03L-0:on 830508,while in Mode 2,fire Detection Sys Zones 72 & 149 Declared Inoperable Due to Alarms Remaining in Alarm Condition.Fire Watch Patrols Established. Caused by Control Interface Module failure.W830527 Ltr | |
| 05000369/LER-1983-026-03, /03L-0:on 830430,performance of RCS Leakage Calculation Determined Unidentified Leakage Greater than 1 Gpm.Caused by Leakage Past Bonnet Seal Ring on Valves 1NC-18 & 1NV-239.Valves Sealed | /03L-0:on 830430,performance of RCS Leakage Calculation Determined Unidentified Leakage Greater than 1 Gpm.Caused by Leakage Past Bonnet Seal Ring on Valves 1NC-18 & 1NV-239.Valves Sealed | |
| 05000369/LER-1983-027-03, /03L-0:on 830505,discovery of Water in Outside Air Pressure Filter Train 2 Led to Control Area Ventilation Sys Train B Inoperability.Caused by Water Backflow Through Drain Lines Into Filter Package.Filter Cleaned | /03L-0:on 830505,discovery of Water in Outside Air Pressure Filter Train 2 Led to Control Area Ventilation Sys Train B Inoperability.Caused by Water Backflow Through Drain Lines Into Filter Package.Filter Cleaned | |
| 05000369/LER-1983-028-01, /01T-0:on 830525,impulse Lines for Two Redundant Steam Generator 1D Level Instruments Came within 2 Inches of Each Other at One Point.Caused by Const/Installation Deficiency.One Line Rerouted | /01T-0:on 830525,impulse Lines for Two Redundant Steam Generator 1D Level Instruments Came within 2 Inches of Each Other at One Point.Caused by Const/Installation Deficiency.One Line Rerouted | |
| 05000369/LER-1983-029-03, /03L-0:on 830510 & 15,boron Concentration Dropped Below 1,900 Ppm in Cold Leg Injection Accumulator.Caused by Leakage Into Accumulator from RCS Through Check Valves 1NI70 & 1NI71.Valves Repaired | /03L-0:on 830510 & 15,boron Concentration Dropped Below 1,900 Ppm in Cold Leg Injection Accumulator.Caused by Leakage Into Accumulator from RCS Through Check Valves 1NI70 & 1NI71.Valves Repaired | |
| 05000369/LER-1983-029-01, /01T-0:on 830601,Westinghouse Notified Util That Extended Operation at Low Power & Subsequent Escalation to Power in Same Fuel Cycle Would Result in Heat Flux Hot Channel Factor Limit Violations for LOCA Analysis | /01T-0:on 830601,Westinghouse Notified Util That Extended Operation at Low Power & Subsequent Escalation to Power in Same Fuel Cycle Would Result in Heat Flux Hot Channel Factor Limit Violations for LOCA Analysis | |
| 05000369/LER-1983-030-01, /01T-0:on 830526,discovered Monthly Test of Containment Pressure Control Sys Failed to Satisfy Surveillance Requirements to Check Permissive/Termination Setpoint Accuracy.Alarm Modules Recalibr | /01T-0:on 830526,discovered Monthly Test of Containment Pressure Control Sys Failed to Satisfy Surveillance Requirements to Check Permissive/Termination Setpoint Accuracy.Alarm Modules Recalibr | |
| 05000369/LER-1983-031-03, /03L-0:on 830512,reactor Coolant Pump Taken Out of Svc Following Sporadic Low Oil Level Alarms from Pump Motor 1D Upper Reservoir.Level Found Slightly Low.Cause Not Determined.Oil Added.Pump Restarted | /03L-0:on 830512,reactor Coolant Pump Taken Out of Svc Following Sporadic Low Oil Level Alarms from Pump Motor 1D Upper Reservoir.Level Found Slightly Low.Cause Not Determined.Oil Added.Pump Restarted | |
| 05000369/LER-1983-032-03, /03L-0:on 830513,control Area Ventilation Sys Train a Failed to Meet Pressurization Criteria.Caused by Degradation of Door Seals & Lack of Trip Interlocks.Door Seals Taped & Later Replaced.Test Rerun | /03L-0:on 830513,control Area Ventilation Sys Train a Failed to Meet Pressurization Criteria.Caused by Degradation of Door Seals & Lack of Trip Interlocks.Door Seals Taped & Later Replaced.Test Rerun | |
| 05000369/LER-1983-033-03, /03L-0:on 830701,two Programmed Setpoint Circuit Cards of Each Steam Generator Water Level low-low Channel Not Tested During Required Monthly Surveillance.Cause Not Known.Monthly Surveillance Procedure Revised | /03L-0:on 830701,two Programmed Setpoint Circuit Cards of Each Steam Generator Water Level low-low Channel Not Tested During Required Monthly Surveillance.Cause Not Known.Monthly Surveillance Procedure Revised | |