Finding | |
---|---|
Title | Inadequate Design Control for 4 kV Bus Degraded Voltage Relay Bases |
Description | The team identified a finding of very low safety significance (Green) involving anon-cited violation of 10 CFR 50, Appendix B, Criterion III, Design Control, in that PSEG had not verified the adequacy of design with respect to establishing the bases for the degraded voltage relay (DVR) setpoint. Specifically, PSEG\'s calculation to verify the DVR setpoint utilized a non-conservative voltage input to analyze motor starting during accident load sequencing and assumed an inappropriate modeling technique for running motors that minimized the voltage dips during motor starting. Additionally, PSEG\'s analyses had not analyzed the capability of motor starting during steady state conditions following load sequencing. PSEG entered the issue into their corrective action program and prepared preliminary calculations to assess the cumulative effect of the nonconservative assumptions on the voltage available to motors starting during load sequencing. The calculations showed that although margins were substantially reduced, the motors would still be afforded their minimum required starting voltage. The finding was more than minor because it was associated with the design control attribute of the Mitigating Systems Cornerstone and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The team determined the finding was of very low safety significance (Green) because it was a design deficiency confirmed not to result in a loss of the electrical distribution system operability or functionality. This finding did not have a cross-cutting aspect because the issue was not considered to be indicative of current licensee performance. |
Site: | Hope Creek |
---|---|
Report | IR 05000354/2009007 Section 1R21 |
Date counted | Dec 31, 2009 (2009Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | G Skinner F Arner A Ziedonis D Orr L Doerflein J Richmond C Baron |
INPO aspect | |
' | |
Finding - Hope Creek - IR 05000354/2009007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Hope Creek) @ 2009Q4
Self-Identified List (Hope Creek)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||