05000348/FIN-2012003-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Implement Design Control Measures to Verify the Adequacy of CST Design |
| Description | The inspectors identified a Green non-cited violation of 10 CFR 50, Appendix B, Criterion III, Design Control, for the licensees failure to implement design control measures to verify the adequacy of design inputs, assumptions, or limiting plant conditions which were relied upon in the design basis analyses used to demonstrate the adequacy of condensate storage tank (CST) design. The licensee entered these issues into their corrective action program as condition reports 351170, 353599, and 355457. The licensee performed operability evaluations in support of current operability and implemented additional compensatory measures to ensure that CST level would be maintained above the condenser hotwell make-up elevation pending completion of proposed long term corrective actions. These proposed corrective actions included the more detailed design basis analysis required to support a license amendment request to increase the minimum volume of water specified by the limiting condition for operation in Technical Specification 3.7.6. The failure to utilize conservative design inputs, assumptions, or limiting plant conditions when implementing design control measures to verify the adequacy of CST design was a performance deficiency. The performance deficiency was determined to be more than minor because it was associated with the mitigating systems cornerstone attribute of design control and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. In accordance with NRC inspection manual chapter 0609.04, Initial Screening and Characterization of Findings, the inspectors used the mitigating systems column to perform a phase 1 significance determination process screening, and determined the finding to be of very low safety significance (Green). This determination was based on the fact that the performance deficiency was not a design issue resulting in loss of function, did not represent an actual loss of a system safety function, did not result in exceeding a Technical Specification allowed outage time, and did not affect external event mitigation. A cross-cutting aspect was not identified because the design basis calculation associated with the performance deficiency was last approved on March 25, 1999, and therefore, did not represent current licensee performance. |
| Site: | Farley |
|---|---|
| Report | IR 05000348/2012003 Section 1R21 |
| Date counted | Jun 30, 2012 (2012Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | E Crowe A Nielsen F Ehrhardt G Kuzo S Sandal B Collins J Sowa C Dykes |
| INPO aspect | |
| ' | |
Finding - Farley - IR 05000348/2012003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Farley) @ 2012Q2
Self-Identified List (Farley)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||