LER-1982-007, Forwards LER 82-007/03L-0
Event date:
Report date:
3351982007R00 - NRC Website

text

~

' %f FLORIDA POWER & LIGHT COMPANY G

W G

N e

EECEn!2D

'a N

Y APR 7 1982r-March 24,19823

~

'3 p'4 nr.n mem mer maigpntu PRN-LI-82-11DJ h

v Q

..~

Mr. James P. O'Reilly

)

Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

REPORTABLE OCCURRENCE 335-82-07 ST. LUCIE UNIT 1 DATE OF OCCURRENCE:

FEBRUARY 18, 1982 TECHNICAL SPECIFICAILON 4.6.6.1.a SHIELD BUILDING VENTILATION SYSTEM The attached Licensee Event Report is being submitted in accordance with Technical Specification 6.9 to provide 30 day notification of the subject occurrence.

This Report is submitted past the usual time period due to an internal coordination problem.

Very truly yours,

&v J. W. Williams, Jr.

Vice President Nuclear Energy PLP/ cab f

Attachment cc: Di rector, Of f t..t: of Inspection and Enforcement (30)

Harold F. Reis. Esquire File 933.1 SL M*

4 O

CSh

$DRADOCK204000191 820324 05000335 gi S

PEOPLE.. SERVING PL LE