05000327/FIN-2010004-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Non-Conservative Design Calculation for RHR Suction Temperature Limit |
| Description | The inspectors identified a Green non-cited violation of 10 CFR 50 Appendix B Criterion III, Design Control, for the failure to provide design control measures for verifying the adequacy of the design calculation used to establish the maximum RHR operating temperature limit for maintaining ECCS operability. A design calculation yielded a non-conservative temperature limit for use in plant operations procedures. This resulted in several occasions where ECCS operability was in question due to the fluid temperature in the RHR system suction piping. The licensee entered this issue into their corrective action program as PER 215434. Corrective actions included revising operations procedures to reflect the corrected temperature limit from a revised calculation. The finding was determined to be greater than minor because it was similar to example 3.j. of IMC 0612 Appendix E in that the non-conservatism in the calculation resulted in a condition where reasonable doubt existed as to the operability of the ECCS system. Additionally, it was associated with the procedure quality attribute of the mitigating systems cornerstone and affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, plant procedures for RHR system operation contained non-conservative temperature limits for ensuring TS operability, and actual system temperatures exceeded the revised appropriate limit on several occasions. Using IMC 0609, Significance Determination Process, Attachment 4, Phase 1 - Initial Screening and Characterization of Findings, the finding was determined to be of very low safety significance (Green) since the finding did not represent an actual loss of safety function. No cross-cutting aspect was identified since the issue was not reflective of current licensee performance, since the previous calculation in question was last revised and approved in 1996. (Section 4OA2.3 |
| Site: | Sequoyah |
|---|---|
| Report | IR 05000327/2010004 Section 4OA2 |
| Date counted | Sep 30, 2010 (2010Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | W Deschaine E Guthrie C Young M Speck |
| INPO aspect | |
| ' | |
Finding - Sequoyah - IR 05000327/2010004 | ||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Sequoyah) @ 2010Q3
Self-Identified List (Sequoyah)
| ||||||||||||||||||||||||||||||||||||||||||||||||||