05000327/FIN-2010007-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Violation of 10 CFR 50, Appendix B, Criterion V for Failure to Follow Procedure for Vendor Contact Program |
Description | The team identified a Green non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the failure to properly maintain the vendor contact program for safety-related components. The team identified 37 examples of vendor technical manuals where the associated vendor had not been contacted in over three years. Procedure SPP- 2.5, Vendor Manual Control, required contact to be made with the vendors of safety-related components every three years to ensure that technical manuals . and vendor documents contained the most current and applicable information consistent with the guidance of Generic Letter (GL) 90-03. The team identified 37 examples of vendor manuals and technical documents where the associated vendor had not been contacted in more than three years with several examples extending to almost six years. The licensee entered this issue into their corrective action program with actions to make contact with the vendors for all documents identified as having not been verified with the vendor in over the required three years. This finding was entered into the licensees corrective action program as problem evaluation reports (PERs) 224364 and 224975. As an immediate corrective action, the licensee is ensuring that the vendor manuals and documents associated with safety-related components are being verified as most current with the respective vendors. This finding is more than minor because it affected the Mitigating Systems Cornerstone objective of ensuring the availability and reliability of safety systems, is related to the attribute of Procedure Quality (i.e., Maintenance and Testing (Pre-Event) Procedures) and represented a programmatic break-down which if left uncorrected, could become a more significant safety concern. The team assessed this finding using the SDP and determined that the finding was of very low safety significance (Green) because the inspectors found no documented occurrences where the lack of vendor contact ultimately resulted in the inability of a safety-related component to perform the intended safety function and will be treated as an NCV. The inspectors determined that the thorough evaluation of problems such that the resolutions address problems and extent of conditions, as necessary was a significant cause if this performance deficiency. The plant experienced a reactor trip in 2009 which was determined to have been caused, in part, by a vendor manual associated with a feedwater regulating valve (FRV) not being updated. The FRVs are components with both safety-related and non-safety-related features. The extent of condition of the corrective actions associated with this failed to identify the programmatic breakdown of the TVA vendor contact program for safety-related components. This is directly related to the Corrective Action Program component of the cross-cutting area of Problem Identification and Resolution (P.1.(c)). (Section 1R21.2.3) |
Site: | Sequoyah ![]() |
---|---|
Report | IR 05000327/2010007 Section 1R21 |
Date counted | Jun 30, 2010 (2010Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | R Patterson R Williams S Sandal W Deschaine W Loo C Young E Guthrie L Lake L Mahlahla M Riches M Speck P Higgins R Aiello R Baldwin R Hamiltond Jonesb Desaic Baron D Mas Penaranda G Skinner R Aiello R Berryman R Patterson |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Sequoyah - IR 05000327/2010007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Sequoyah) @ 2010Q2
Self-Identified List (Sequoyah)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||