| | | Reporting criterion |
|---|
| 05000312/LER-1982-001, Forwards LER 82-001/01T-0.Detailed Event Analysis Submitted | Forwards LER 82-001/01T-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-001-01, /01T-0:on 820130,both Doors on Airlock Opened Simultaneously Resulting in Loss of Containment Integrity. Caused by Personnel Error & Failure of Inner Door Mechanism to Latch Properly | /01T-0:on 820130,both Doors on Airlock Opened Simultaneously Resulting in Loss of Containment Integrity. Caused by Personnel Error & Failure of Inner Door Mechanism to Latch Properly | |
| 05000312/LER-1982-002-03, /03L-0:on 820130,snubbers 1SW-21007-7 & 1SW-23823-13A Failed Visual Insps.Caused by Low Fuel Level. Snubber 1SW-21007-7 Rebuilt & Passed.Snubber 1SW-23823-13A Failed Until Bechtel Developed New Criteria | /03L-0:on 820130,snubbers 1SW-21007-7 & 1SW-23823-13A Failed Visual Insps.Caused by Low Fuel Level. Snubber 1SW-21007-7 Rebuilt & Passed.Snubber 1SW-23823-13A Failed Until Bechtel Developed New Criteria | |
| 05000312/LER-1982-002, Forwards LER 82-002/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-002/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-003-01, /01T-0:on 820301,B HPI Pump Found to Be Inoperable Due to Leaving Dc Charging Motion for Closing Spring in Unenergized State.Probably Caused by Personnel Error or Improper Procedure.Addl Training Provided | /01T-0:on 820301,B HPI Pump Found to Be Inoperable Due to Leaving Dc Charging Motion for Closing Spring in Unenergized State.Probably Caused by Personnel Error or Improper Procedure.Addl Training Provided | |
| 05000312/LER-1982-003, Forwards LER 82-003/01T-0.Detailed Event Analysis Submitted | Forwards LER 82-003/01T-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-004-03, /03L-0:on 820209,reactor Protection Sys Channel C Pressure Transmitter Read 15 Psi High.Caused by Calibr of Transmitter During Artificial Cooling of Ambient Temp by Emergency Cooler.Input Buffer Amp Bias Changed | /03L-0:on 820209,reactor Protection Sys Channel C Pressure Transmitter Read 15 Psi High.Caused by Calibr of Transmitter During Artificial Cooling of Ambient Temp by Emergency Cooler.Input Buffer Amp Bias Changed | |
| 05000312/LER-1982-004, Forwards LER 82-004/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-004/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-005, Forwards LER 82-005/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-005/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-005-03, /03L-0:on 820211,B Diesel Generator Found Inoperable.Caused by Output Breaker lock-out Due to Reverse Power Trip.Relays Marked to Improve Identification of Flag Targets,Personnel Trained & lock-out Alarm Moved | /03L-0:on 820211,B Diesel Generator Found Inoperable.Caused by Output Breaker lock-out Due to Reverse Power Trip.Relays Marked to Improve Identification of Flag Targets,Personnel Trained & lock-out Alarm Moved | |
| 05000312/LER-1982-006-04, /04T-0:on 820305,during Review of Plant Effluent Records,Discovered That Ph Limit Was Exceeded on 820219. Caused by Sample Sys Configuration for Regenerate Hold Up Tank Discharging Into Plant Waste Stream.Sys Modified | /04T-0:on 820305,during Review of Plant Effluent Records,Discovered That Ph Limit Was Exceeded on 820219. Caused by Sample Sys Configuration for Regenerate Hold Up Tank Discharging Into Plant Waste Stream.Sys Modified | |
| 05000312/LER-1982-006, Forwards LER 82-006/04T-0 | Forwards LER 82-006/04T-0 | |
| 05000312/LER-1982-007-04, /04T-0:on 820305,monthly Review of Plant Effluent Records Revealed Plant Effuent Chlorine Limit Exceeded for Period of 2.5-hr on 820217.Caused by Analyst Failing to Take Sample at Site Boundary.Analysis Reinstructed | /04T-0:on 820305,monthly Review of Plant Effluent Records Revealed Plant Effuent Chlorine Limit Exceeded for Period of 2.5-hr on 820217.Caused by Analyst Failing to Take Sample at Site Boundary.Analysis Reinstructed | |
| 05000312/LER-1982-007, Forwards LER 82-007/04T-0 | Forwards LER 82-007/04T-0 | |
| 05000312/LER-1982-008-04, /04T-0:on 820121,plant Effluent Ph Found to Be High (8.6-8.7) for Approx 5 Minutes.Caused by Instrument Error.Rh & Delta TC Probes Replaced | /04T-0:on 820121,plant Effluent Ph Found to Be High (8.6-8.7) for Approx 5 Minutes.Caused by Instrument Error.Rh & Delta TC Probes Replaced | |
| 05000312/LER-1982-008, Forwards LER 82-008/04T-0 | Forwards LER 82-008/04T-0 | |
| 05000312/LER-1982-009, Forwards LER 82-009/01T-0.Detailed Event Analysis Submitted | Forwards LER 82-009/01T-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-009-01, /01T-0:on 820405,radiographic & Ultrasonic Exam of High Pressure Injection Nozzles Revealed Unacceptable Condition in a & B Nozzles.Cause Not stated.Safe-ends Will Be Replaced W/New Design | /01T-0:on 820405,radiographic & Ultrasonic Exam of High Pressure Injection Nozzles Revealed Unacceptable Condition in a & B Nozzles.Cause Not stated.Safe-ends Will Be Replaced W/New Design | |
| 05000312/LER-1982-010, Forwards LER 82-010/01T-1.Optimum Repair Schedule Encl | Forwards LER 82-010/01T-1.Optimum Repair Schedule Encl | |
| 05000312/LER-1982-010-01, /01T-1:on 820419,insp of B once-through Steam Generator Auxiliary Feedwater Header Ring & a Ring on 820420 Revealed Deformations.Mod Work to Correct Problem Partially Scheduled.Old Header Will Be Stabilized | /01T-1:on 820419,insp of B once-through Steam Generator Auxiliary Feedwater Header Ring & a Ring on 820420 Revealed Deformations.Mod Work to Correct Problem Partially Scheduled.Old Header Will Be Stabilized | |
| 05000312/LER-1982-011-03, /03L-0:on 820415,check Valve CBS-022 on B Tank Supply to B Pump Found Stuck Closed.Caused by Chemical Deposit Buildup.Check Valves Cleaned,Reground & Returned to Svc | /03L-0:on 820415,check Valve CBS-022 on B Tank Supply to B Pump Found Stuck Closed.Caused by Chemical Deposit Buildup.Check Valves Cleaned,Reground & Returned to Svc | |
| 05000312/LER-1982-011, Forwards LER 82-011/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-011/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-012, Forwards LER 82-012/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-012/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-012-03, /03L-0:on 820505,during Cold Shutdown,A Decay Heat Pump Inboard Bearing Found Leaking Oil.Cause of Leak Undetermined.Probable Cause Due to Partial Seal Failure.Leak Will Be Repaired | /03L-0:on 820505,during Cold Shutdown,A Decay Heat Pump Inboard Bearing Found Leaking Oil.Cause of Leak Undetermined.Probable Cause Due to Partial Seal Failure.Leak Will Be Repaired | |
| 05000312/LER-1982-013, Forwards LER 82-013/04T-0.Detailed Event Analysis Submitted | Forwards LER 82-013/04T-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-013-04, /04T-0:on 820607,during Chlorination of Nuclear Svc Spray Pond,Spray Pond Filters Went Into Backwash Mode. Cause Not Stated.Several Fish in Discharge Stream Killed Due to Excessive Chlorine.Chlorine Injection Point to Be Mov | /04T-0:on 820607,during Chlorination of Nuclear Svc Spray Pond,Spray Pond Filters Went Into Backwash Mode. Cause Not Stated.Several Fish in Discharge Stream Killed Due to Excessive Chlorine.Chlorine Injection Point to Be Moved | |
| 05000312/LER-1982-014, Forwards LER 82-014/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-014/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-014-03, /03L-0:on 820619,pressurizer Liquid Sample Valve, SFV-70001,opened Properly But Failed to Close Properly on Command.Caused by Ax Relay Not Responding to Close Command. Relay Replaced | /03L-0:on 820619,pressurizer Liquid Sample Valve, SFV-70001,opened Properly But Failed to Close Properly on Command.Caused by Ax Relay Not Responding to Close Command. Relay Replaced | |
| 05000312/LER-1982-023, Forwards LER 82-023/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-023/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-023-03, /03L-0:on 820909,weekly Nitrogen Sys Surveillance Showed Xe-133 Activity in Auxiliary Bldg Nitrogen Header. Cause Undetermined.Investigation Will Be Conducted.Followup Rept on Cause & Corrective Actions Will Be Provided | /03L-0:on 820909,weekly Nitrogen Sys Surveillance Showed Xe-133 Activity in Auxiliary Bldg Nitrogen Header. Cause Undetermined.Investigation Will Be Conducted.Followup Rept on Cause & Corrective Actions Will Be Provided | |
| 05000312/LER-1982-026-04, /04T-0:on 821006,review of Plant Effluent Records Disclosed Ph Reading of 6.2 for Less than 15 Minutes on 820918.Caused by Leaks at Two Elbows in Acid Line Running from Storage Tank to Turbine Bldg.Leaks Repaired | /04T-0:on 821006,review of Plant Effluent Records Disclosed Ph Reading of 6.2 for Less than 15 Minutes on 820918.Caused by Leaks at Two Elbows in Acid Line Running from Storage Tank to Turbine Bldg.Leaks Repaired | |
| 05000312/LER-1982-027-03, /03L-0:on 821012,weekly Surveillance of Nitrogen Sys Revealed Presence of Contamination in Form of Xe-133. Cause Undetermined.Sys Purged & Activities Reduced to Below Detectable Levels.Investigation Underway.Rept Will Follow | /03L-0:on 821012,weekly Surveillance of Nitrogen Sys Revealed Presence of Contamination in Form of Xe-133. Cause Undetermined.Sys Purged & Activities Reduced to Below Detectable Levels.Investigation Underway.Rept Will Follow | |
| 05000312/LER-1982-027, Forwards LER 82-027/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-027/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-028-99, /99X-0:on 820922,small Pieces of Matl Resembling Paint Chips Observed During Flow Control Valve Repair in Auxiliary Bldg Fire Protection Sys.Probably Caused by Detached Liner Matl.Piping to Be Inspected & Repaired | /99X-0:on 820922,small Pieces of Matl Resembling Paint Chips Observed During Flow Control Valve Repair in Auxiliary Bldg Fire Protection Sys.Probably Caused by Detached Liner Matl.Piping to Be Inspected & Repaired | |
| 05000312/LER-1982-028, Forwards LER 82-028/99X-0.Detailed Event Analysis Submitted | Forwards LER 82-028/99X-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-029, Forwards LER 82-029/03L-0.Detailed Event Analysis Submitted | Forwards LER 82-029/03L-0.Detailed Event Analysis Submitted | |
| 05000312/LER-1982-029-03, /03L-0:on 821026,QA Dept Reported That Portion of Auxiliary Feedwater Start Circuit Was Not Being Tested Per Requirements.Caused by Transposed Requirements in Tech Specs.Tech Specs Will Be Amended | /03L-0:on 821026,QA Dept Reported That Portion of Auxiliary Feedwater Start Circuit Was Not Being Tested Per Requirements.Caused by Transposed Requirements in Tech Specs.Tech Specs Will Be Amended | |