Finding | |
|---|---|
| Title | Failure to Document Degraded Conditions in the Corrective Action Process |
| Description | The inspectors identified a Green non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and drawings, in that the licensee did not enter degraded conditions into the corrective action process. The inspectors identified two examples. Specifically, on May 12-13, 2014, the licensee experienced high temperatures in the 480 volt vital bus rooms and did not initiate a notification to document the unexpected condition. Second, on May 20, 2014, the licensee failed to document that a 480 volt vital bus room ventilation system register louvers was found closed. The failure to enter problems into the corrective action process on the 480 volt busses was a performance deficiency. The performance deficiency was more than minor because it was associated with the human performance attribute of the Mitigating Systems Cornerstone and it adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences, and is therefore a finding. Using Inspection Manual Chapter 0609, Attachment 04, Initial Characterization of Findings, and Appendix A, Exhibit 2, Mitigating Systems Screening Questions, this finding was determined to be of very low safety significance (Green) because, it was not a design or qualification deficiency, was not a loss of the system or function, and did not represent an actual loss of function of a single train for greater than its technical specification allowed outage time. The inspectors determined this finding has a human performance cross-cutting aspect associated with challenging the unknown attribute, specifically in that licensee personnel did not maintain a questioning attitude to resolve unexpected conditions. |
| Site: | Diablo Canyon |
|---|---|
| Report | IR 05000275/2014004 Section 1R15 |
| Date counted | Sep 30, 2014 (2014Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | C Alldredge C Osterholtz J Mateychick J O'Donnell J Reynoso L Carson L Micewski L Ricketson M Bloodgood N Greene T Hipschman W Walker |
| Violation of: | 10 CFR 50 Appendix B Criterion V Technical Specification Technical Specification - Procedures |
| CCA | H.11, Challenge the Unknown |
| INPO aspect | QA.2 |
| ' | |