| 05000261/LER-1982-001-03, /03L-0:on 820129,TC-412B,dual Comparator - Loop 1, Overpower Delta-T,found Out of Acceptable Tolerance in Nonconservative Direction During Periodic Test 5.1.Caused by Defective Instrument supply.TC-412B Replaced,Calibr,Teste | /03L-0:on 820129,TC-412B,dual Comparator - Loop 1, Overpower Delta-T,found Out of Acceptable Tolerance in Nonconservative Direction During Periodic Test 5.1.Caused by Defective Instrument supply.TC-412B Replaced,Calibr,Tested | |
| 05000261/LER-1982-001, Forwards LER 82-001/03L-0 | Forwards LER 82-001/03L-0 | |
| 05000261/LER-1982-002, Forwards LER 82-002/03L-0 | Forwards LER 82-002/03L-0 | |
| 05000261/LER-1982-002-03, /03L-0:on 820207,condensate Measuring Sys Breaker HVH-1 Tripped During Periodic Testing.Caused by Reverse Rotation Due to Missing Discharge Damper Louver.Reverse Rotation Stopped.Damper Repairs Underway | /03L-0:on 820207,condensate Measuring Sys Breaker HVH-1 Tripped During Periodic Testing.Caused by Reverse Rotation Due to Missing Discharge Damper Louver.Reverse Rotation Stopped.Damper Repairs Underway | |
| 05000261/LER-1982-003-01, /01T-0:on 820209,pressurization of Boron Injection Tank Header Pressure Indicator PI-934 Observed Exceeding Psig Required by Tech Specs.Caused by Failure of Operator & Safety Valve SI-857A to Relieve Pressure | /01T-0:on 820209,pressurization of Boron Injection Tank Header Pressure Indicator PI-934 Observed Exceeding Psig Required by Tech Specs.Caused by Failure of Operator & Safety Valve SI-857A to Relieve Pressure | |
| 05000261/LER-1982-004, Forwards LER 82-004/01T-0 | Forwards LER 82-004/01T-0 | |
| 05000261/LER-1982-004-01, /01T-0:on 820426,insp of Steam Generators B & C Revealed 173 Defective Tubes.Total Was More than 1% of Total Number of Tubes,Placing Results in Category C-3.All Defective Tubes Mechanically Plugged | /01T-0:on 820426,insp of Steam Generators B & C Revealed 173 Defective Tubes.Total Was More than 1% of Total Number of Tubes,Placing Results in Category C-3.All Defective Tubes Mechanically Plugged | |
| 05000261/LER-1982-005-01, /01T-0:on 820628,during Refueling Shutdown,Main Steam Check Valve Discovered in Degraded Condition.Caused by Set Screws Loosened on Valve Disc Tail Pieces.All Three Valves Modified to Correct post-mod Deficiency | /01T-0:on 820628,during Refueling Shutdown,Main Steam Check Valve Discovered in Degraded Condition.Caused by Set Screws Loosened on Valve Disc Tail Pieces.All Three Valves Modified to Correct post-mod Deficiency | |
| 05000261/LER-1982-005, Forwards LER 82-005/01T-0 | Forwards LER 82-005/01T-0 | |
| 05000261/LER-1982-006, Forwards LER 82-006/01T-0 | Forwards LER 82-006/01T-0 | |
| 05000261/LER-1982-007, Forwards LER 82-007/01T-0 | Forwards LER 82-007/01T-0 | |
| 05000261/LER-1982-007-01, /01T-0:on 820717,during Plant Heatup from Refueling Outage,Primary to Secondary Leak in a Steam Generator Confirmed.Caused by Defective Weld.Leaking Welded Plug Removed & Mechanical Plug Installed | /01T-0:on 820717,during Plant Heatup from Refueling Outage,Primary to Secondary Leak in a Steam Generator Confirmed.Caused by Defective Weld.Leaking Welded Plug Removed & Mechanical Plug Installed | |
| 05000261/LER-1982-008, Forwards LER 82-008/03L-0 | Forwards LER 82-008/03L-0 | |
| 05000261/LER-1982-008-03, /03L-0:on 820710,summator NM-412C Found Inoperable During Periodic Test 5.1.Caused by Summator Failing to Zero Output.Summator Replaced | /03L-0:on 820710,summator NM-412C Found Inoperable During Periodic Test 5.1.Caused by Summator Failing to Zero Output.Summator Replaced | |
| 05000261/LER-1982-009, Forwards LER 82-009/03L-0 | Forwards LER 82-009/03L-0 | |
| 05000261/LER-1982-009-03, /03L-0:on 820715 & 27,motor Operated Valve RHR-759A,RHR HX Discharge Valve a Failed to Open.Caused by Improper Setting of Motor Operator Torque Switch W/Insufficient Lubrication of Valve Stem & Packing | /03L-0:on 820715 & 27,motor Operated Valve RHR-759A,RHR HX Discharge Valve a Failed to Open.Caused by Improper Setting of Motor Operator Torque Switch W/Insufficient Lubrication of Valve Stem & Packing | |
| 05000261/LER-1982-010, Forwards LER 82-010/01T-0 | Forwards LER 82-010/01T-0 | |
| 05000261/LER-1982-010-01, /01T-0:on 820803,control Rod Drive Mechanism for Rod L-11 Observed to Have Steam Leaking from 1/4-inch Vent Valve at Top.Caused by Vent Valve Being Improperly Torqued Shut During Repair in 1982 Outage | /01T-0:on 820803,control Rod Drive Mechanism for Rod L-11 Observed to Have Steam Leaking from 1/4-inch Vent Valve at Top.Caused by Vent Valve Being Improperly Torqued Shut During Repair in 1982 Outage | |
| 05000261/LER-1982-011, Forwards LER 82-011/03L-0 | Forwards LER 82-011/03L-0 | |
| 05000261/LER-1982-011-03, /03L-0:on 820811,double Disc Gate Valve SI-861A Failed to Open Fully During Startup.Caused by Deformation of Valve Disc Due to Disc Interspace Overpressurization Resulting from Sys Heatup.Valve Discs Replaced | /03L-0:on 820811,double Disc Gate Valve SI-861A Failed to Open Fully During Startup.Caused by Deformation of Valve Disc Due to Disc Interspace Overpressurization Resulting from Sys Heatup.Valve Discs Replaced | |
| 05000261/LER-1982-012, Forwards LER 82-012/03L-0 | Forwards LER 82-012/03L-0 | |
| 05000261/LER-1982-012-03, /03L-0:on 820906,at 94% Power,Letdown Relief Valve CVC-203 Lifted & Would Not Reseat.Caused by Water Hammer Due to Operator Error in Realignment of Charging Pump from Recirculation to Normal Operation.Operator Counseled | /03L-0:on 820906,at 94% Power,Letdown Relief Valve CVC-203 Lifted & Would Not Reseat.Caused by Water Hammer Due to Operator Error in Realignment of Charging Pump from Recirculation to Normal Operation.Operator Counseled | |
| 05000261/LER-1982-013-03, /03L-0:on 820923,svc Water Pump a Failed to Restart Following Periodic Test.Caused by Failed Control Power Fuses.Fuses Replaced & Pump Started & Retested | /03L-0:on 820923,svc Water Pump a Failed to Restart Following Periodic Test.Caused by Failed Control Power Fuses.Fuses Replaced & Pump Started & Retested | |
| 05000261/LER-1982-013, Forwards LER 82-013/03L-0 | Forwards LER 82-013/03L-0 | |
| 05000261/LER-1982-014-03, /03L-0:on 821012,letdown Relief Valve CVC-203 Lifted & Did Not Reseat Completely.Cause of Valve Lifting Undetermined.Failure to Reseat Caused by Seat Damage Due to Valve Chatter.Valve Repaired & Returned to Svc | /03L-0:on 821012,letdown Relief Valve CVC-203 Lifted & Did Not Reseat Completely.Cause of Valve Lifting Undetermined.Failure to Reseat Caused by Seat Damage Due to Valve Chatter.Valve Repaired & Returned to Svc | |
| 05000261/LER-1982-014, Forwards LER 82-014/03L-0 | Forwards LER 82-014/03L-0 | |
| 05000261/LER-1982-015-03, /03L-0:on 821019,during Performance of Periodic Test,Comparator LC-485A Found Inoperable.Cause Not Determined.Defective Comparator Replaced W/Spare Unit | /03L-0:on 821019,during Performance of Periodic Test,Comparator LC-485A Found Inoperable.Cause Not Determined.Defective Comparator Replaced W/Spare Unit | |
| 05000261/LER-1982-015, Forwards LER 82-015/03L-0 | Forwards LER 82-015/03L-0 | |
| 05000261/LER-1982-016-03, /03L-0:on 821103,containment Fan Cooler HVH-3 Failed to Restart During Periodic Test Performance.Caused by Defective Time Delay Relay in Motor Breaker Control Circuit.Time Delay Relay Replaced | /03L-0:on 821103,containment Fan Cooler HVH-3 Failed to Restart During Periodic Test Performance.Caused by Defective Time Delay Relay in Motor Breaker Control Circuit.Time Delay Relay Replaced | |
| 05000261/LER-1982-016, Forwards LER 82-016/03L-0 | Forwards LER 82-016/03L-0 | |
| 05000261/LER-1982-017, Forwards LER 82-017/01L-0 | Forwards LER 82-017/01L-0 | |
| 05000261/LER-1982-017-01, /01L-0:on 821104,w/unit at 80% Power,Operator Discovered Isolation Valve Tank Isolation Valve Closed.Cause Undetermined.Valve Locked Open & Procedures Changed to Ensure That Valve Remains Open | /01L-0:on 821104,w/unit at 80% Power,Operator Discovered Isolation Valve Tank Isolation Valve Closed.Cause Undetermined.Valve Locked Open & Procedures Changed to Ensure That Valve Remains Open | |
| 05000261/LER-1982-018-01, /01L-0:on 821213,at 81% Power,Low Temp Overpressure Protection Sys Pressure Transmitters Found Calibr Incorrectly.Caused by Calculational Error on Zero Adjust Correction on Initial 1978 Calibr Data Sheets | /01L-0:on 821213,at 81% Power,Low Temp Overpressure Protection Sys Pressure Transmitters Found Calibr Incorrectly.Caused by Calculational Error on Zero Adjust Correction on Initial 1978 Calibr Data Sheets | |
| 05000261/LER-1982-018, Forwards LER 82-018/01L-0 | Forwards LER 82-018/01L-0 | |
| 05000261/LER-1982-019-01, /01L-0:on 821217,calculated That on 821122,boron Injection Tank Vol May Have Fallen Below Level Required by Tech Spec.Caused by Boiling & Draining of Recirculation Lines During Attempt to Dissolve Solidified Boric Acid | /01L-0:on 821217,calculated That on 821122,boron Injection Tank Vol May Have Fallen Below Level Required by Tech Spec.Caused by Boiling & Draining of Recirculation Lines During Attempt to Dissolve Solidified Boric Acid | |