| | Q | CCA | Title |
|---|
| 05000259/FIN-2010004-04 | 2010Q3 | P.2 | Failure to Perform Functional Evaluations for Gas Identified During Venting |
| 05000259/FIN-2010004-01 | 2010Q3 | | Uncontrolled Materials Adversely Impacted the Capability of the EDG Building Emergency Drainage System to Mitigate an Internal Flooding Event |
| 05000259/FIN-2010006-02 | 2010Q3 | H.8 | Failure to Implement the Provisions of Preventative Maintenance (PM) Program Which Contributed to a Manual Reactor Scram |
| 05000259/FIN-2010004-03 | 2010Q3 | P.3 | Failure to Adequately Test Molded Case Circuit Breakers |
| 05000259/FIN-2010004-02 | 2010Q3 | H.8 | Failure to Adequately Assess Online Risk Associated With Maintenance Activities on Risk Significant SSCs |
| 05000259/FIN-2010006-06 | 2010Q3 | H.7 | Inadequate Maintenance Procedure for Siemens Horizontal Vacuum Circuit Breakers Circuit Breakers |
| 05000259/FIN-2010006-05 | 2010Q3 | H.7 | Failure to maintain an Adequate Surveillance Procedure to Prevent an Unplanned HPCI Isolation |
| 05000259/FIN-2010006-03 | 2010Q3 | P.3 | Failure to Correct a Condition Adverse to Quality Associated with the 2D Residual Heat Removal (RHR) Room Cooler |
| 05000259/FIN-2010006-01 | 2010Q3 | P.2 | Failure To Correct The EECW Valves Throttled Below Analyzed Condition |
| 05000259/FIN-2010006-04 | 2010Q3 | P.3 | Failure to Correct a Condition Adverse to Quality Associated Cooling Water Flow Degradation in the 1B Core Spray Room Cooler |
| 05000260/FIN-2010005-01 | 2010Q4 | | RHR Subsystem Inoperable Beyond the TS Allowed Outage Time |
| 05000259/FIN-2011008-01 | 2010Q4 | | RHR Subsystem Inoperable Beyond the TS Allowed Outage Time |
| 05000259/FIN-2010005-02 | 2010Q4 | P.2 | Degraded 1C RHR Motor Rendered One RHR Subsystem Inoperable Beyond the TS Allowed Outage Time |
| 05000259/FIN-2010005-03 | 2010Q4 | | Repeated Failure to Provide Complete and Accurate Information in LER 0500296/2009-003-02 |
| 05000259/FIN-2011002-04 | 2011Q1 | P.1 | Failure to Identify Adverse Trend Resulted in Reactor Scram |
| 05000259/FIN-2011002-03 | 2011Q1 | H.7 | Inadequate TS 5.5.2 Program for Primary Coolant Leaks Outside Containment |
| 05000259/FIN-2011002-02 | 2011Q1 | P.3 | Inadequate Corrective Actions To Address Unit 3 CR120A PCIS Relays That Exceeded Their Recommended Service Life |
| 05000259/FIN-2011002-01 | 2011Q1 | H.5 | Loss of Reactor Water Level during Unit 2 Reactor Reassembly due to a Mispositioned Valve |
| 05000259/FIN-2011002-05 | 2011Q1 | | Repeated Failure to Control Transient Combustibles in Proximity of the Independent Spent Fuel Storage Facility |
| 05000259/FIN-2011402-02 | 2011Q2 | H.8 | Security |
| 05000259/FIN-2011402-01 | 2011Q2 | H.8 | Security |
| 05000259/FIN-2011003-03 | 2011Q2 | | Use of Inappropriately Qualified Methods to Evaluate Emergency Core Cooling During Accident Mitigation |
| 05000259/FIN-2011003-02 | 2011Q2 | P.2 | Over-Pressurization of High Pressure Coolant Injection System due to Stuck Open HPCI System Testable Check Valve |
| 05000259/FIN-2011003-01 | 2011Q2 | H.6 | Failure to Take Corrective Actions to Preclude a Repetitive Functional Failure of an EDG due to Excessive Heat Exchanger Fouling |