05000259/FIN-2011002-04
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Identify Adverse Trend Resulted in Reactor Scram |
Description | A self-revealing finding (FIN) was identified for the licensees failure to adequately evaluate and take the required actions established by site standards to address an adverse system performance trend that had degraded below acceptable levels associated with the main generator exciter air coolers. Specifically, the licensee failed to identify that main generator exciter air cooler differential temperatures exceeded the licensee-defined limit of 10F, and did not initiate a PER as required by the licensees procedural guidance, Nuclear Engineering Department Procedure (NEDP) -20, Conduct of the Engineering Organization, Section 3.1, System Performance Monitoring. Subsequent licensee corrective actions included installing vents on the exciter air coolers to minimize air binding, establishing a process and frequency for venting the exciter air coolers, and increasing engineering supervisory oversight of the system monitoring process. The licensee captured this issue in the corrective action program as PER 301505. This finding is greater than minor because it is associated with the Human Performance attribute of the Initiating Events cornerstone and adversely affected the cornerstone objective to limit the likelihood of those events that upset plant stability. Specifically, the finding resulted in a Unit 3 manual reactor scram due to elevated main turbine bearing vibrations caused by excessive main generator exciter air cooler differential temperatures. The significance of the finding was evaluated using Phase 1 of the significance determination process in accordance with the Inspection Manual Chapter (IMC) 0609 Attachment 4, and was determined to be of very low safety significance (Green) because it did not contribute to both the likelihood of a reactor trip and the likelihood that mitigating equipment or functions were not available. The cause of this finding was directly related to the cross-cutting aspect of Corrective Action Program Implementation in the Corrective Action Program component of the Problem Identification and Resolution area, because the licensee failed to identify the adverse trend of excessive differential temperatures between the exciter air coolers in a timely manner and enter it into the corrective action program. |
Site: | Browns Ferry |
---|---|
Report | IR 05000259/2011002 Section 4OA3 |
Date counted | Mar 31, 2011 (2011Q1) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | A Nielsen C Dykes C Fletcher C Stancil E Guthrie L Pressley M Coursey P Higgins P Niebaum R Hamilton R Patterson S Walker T Ross |
CCA | P.1, Identification |
INPO aspect | PI.1 |
' | |
Finding - Browns Ferry - IR 05000259/2011002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Browns Ferry) @ 2011Q1
Self-Identified List (Browns Ferry)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||