Finding | |
|---|---|
| Title | Failure to Establish a Back-up Radiation Monitor |
| Description | The inspectors identified a finding of very low safety significance and associated NCV of TS 5.5.1 for failure to establish, implement and maintain the Offsite Dose Calculation Manual (ODCM). Specifically, the licensee failed to establish a backup radiation monitor capable of performing monitoring consistent with the primary radiation monitors and ODCM requirements. Over several months, the licensee experienced multiple failures of the steam line and stack radiation monitors. The ODCM provides direction to point a backup monitor at the effected effluent path should the primary monitor fail. The backup radiation monitor could not perform its intended function due to physical obstructions and geometry. The licensee instituted alternate means of monitoring releases when the primary monitor does not work and has entered the condition into the corrective action program. The inspectors concluded that the failure to establish RIA 2328 to be an effective backup for the stack and steam line radiation monitors was a performance deficiency that warranted a significance determination. Since RIA-2328 potentially impacts both Public Radiation Safety and Emergency Planning Cornerstones, the inspectors reviewed the significance under both cornerstones. For radiation protection, the inspectors compared the issue to the examples in Appendix E, and concluded that example 6.b applied. Example 6.b states that a radiation monitor that cannot perform its safety function with a reasonable level of safety margin is an example of a more than minor issue. Further, the inspectors determined the finding was more than minor because it impacted the Public Radiation Safety Cornerstone objective to ensure adequate protection of public health and safety from exposure to radioactive materials released into the public domain as a result of routine civilian nuclear reactor operation and is associated with the program and process attribute. This finding was assessed using IMC 0609, Attachment D for the Public Radiation Safety SDP and determined to be of very low-safety-significance (Green) because this was not a failure to implement the effluent program and public dose remained less than 10 CFR Part 50, Appendix I, limits. In addition, the radiation monitor is used in the emergency plan for determining an emergency action level. The issue screened out as minor in this cornerstone, because there are other EALs that would be available to ensure the correct classification could be met within required times. There was no cross-cutting aspect in that the procedures and radiation monitor have been in place for several years and do not reflect current plant performance. |
| Site: | Palisades |
|---|---|
| Report | IR 05000255/2011003 Section 1R13 |
| Date counted | Jun 30, 2011 (2011Q2) |
| Type: | NCV: Green |
| cornerstone | Emergency Prep, Pr Safety |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.13 |
| Inspectors (proximate) | M Holmberg J Cassidy J Ellegood R Walton T Taylor J Beavers |
| INPO aspect | |
| ' | |
Finding - Palisades - IR 05000255/2011003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Palisades) @ 2011Q2
Self-Identified List (Palisades)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||